speckle imaging
Recently Published Documents


TOTAL DOCUMENTS

533
(FIVE YEARS 111)

H-INDEX

35
(FIVE YEARS 6)

2022 ◽  
Author(s):  
ZHOU GE ◽  
Pei Zhang ◽  
Yizhao Gao ◽  
Hayden K.H. So ◽  
Edmund Lam

2021 ◽  
Vol 12 ◽  
pp. 632
Author(s):  
Andrew P. Carlson ◽  
Taryn Denezpi ◽  
Omar S. Akbik ◽  
Laila M. Mohammad

Background: To measure the degree of relative ischemia caused by skin closure, we explored the potential utility of intraoperative surface blood flow measurement with laser speckle imaging (LSI). Methods: Prospective observational study of eight subjects that underwent intraoperative LSI during elective cranial neurosurgical procedures at the time of skin closure. Results: Seven 1st time incisions, with closure techniques including sutures (n = 3), staples (n = 3), and one after galeal sutures. When compared to the control region, there was a mean 63.7% reduction in flow across all seven subjects (range 18.7–95.32%). Comparing by closure type, a higher flow reduction in the three subjects with suture closure (80.7% reduction) compared to staples (61.9% reduction, P = 0.0379). One subject had a complex wound where tightening and loosening of sutures were performed to ensure adequate perfusion. Suturing resulted in significantly more local decreased flow compared to staples (P < 0.0001). Conclusion: These findings demonstrate the relative feasibility of using LSI for preoperative vascular flow assessment in planning complex incision closure. These data also provide preliminary support for the hypothesis that skin closure itself causes relative ischemia compared to deep approximation or cautery of the skin edge and that the relative ischemia from staples closure is generally less than from suture closure.


2021 ◽  
Author(s):  
Ilya Balmages ◽  
Janis Liepins ◽  
Dmitrijs Bliznuks ◽  
Stivens Zolins ◽  
Ilze Lihacova ◽  
...  

2021 ◽  
Author(s):  
Chammas M. ◽  
Yu C.H. ◽  
H. Gurden ◽  
H. H. Lin ◽  
F. Pain

2021 ◽  
Vol 162 (6) ◽  
pp. 299
Author(s):  
Brian P. Powell ◽  
Veselin B. Kostov ◽  
Saul A. Rappaport ◽  
Andrei Tokovinin ◽  
Avi Shporer ◽  
...  

Abstract We report the discovery of a unique object of uncertain nature—but quite possibly a disintegrating asteroid or minor planet—orbiting one star of the widely separated binary TIC 400799224. We initially identified the system in data from TESS Sector 10 via an abnormally shaped fading event in the light curve (hereafter “dips”). Follow-up speckle imaging determined that TIC 400799224 is actually two stars of similar brightness at 0.″62 separation, forming a likely bound binary with projected separation of ∼300 au. We cannot yet determine which star in the binary is host to the dips in flux. ASAS-SN and Evryscope archival data show that there is a strong periodicity of the dips at ∼19.77 days, leading us to believe that an occulting object is orbiting the host star, though the duration, depth, and shape of the dips vary substantially. Statistical analysis of the ASAS-SN data shows that the dips only occur sporadically at a detectable threshold in approximately one out of every three to five transits, lending credence to the possibility that the occulter is a sporadically emitted dust cloud. The cloud is also fairly optically thick, blocking up to 37% or 75% of the light from the host star, depending on the true host. Further observations may allow for greater detail to be gleaned as to the origin and composition of the occulter, as well as to a determination of which of the two stars comprising TIC 400799224 is the true host star of the dips.


2021 ◽  
Vol 11 (22) ◽  
pp. 10969
Author(s):  
E Du ◽  
Shuhao Shen ◽  
Anqi Qiu ◽  
Nanguang Chen

Laser speckle imaging has been an indispensable tool for visualizing blood flow in biomedical applications. We proposed a novel design of the laser speckle imaging system, which combines confocal illumination and detection with various speckle analysis methods. The system can be operated by three imaging modes. One is surface illumination laser speckle contrast imaging (SI-LSCI) and the other two are line scan temporal speckle contrast imaging (LS-TSCI) and line scan spatial speckle contrast imaging (LS-SSCI). The experimental results of flow phantoms have validated the mixture model, which combines the Lorentzian and Gaussian models to describe the simultaneous existence of both Brownian motions and ordered flow. Our experimental results of in vivo chick embryos demonstrate that LS-SSCI maintains high temporal resolution and is less affected by motion artifacts. LS-SSCI can provide better image quality for in vivo imaging blood chick embryos than LS-TSCI. Furthermore, the experiential results present that LS-SSCI can detect and quantify the blood flow change during vascular clipping, and shows great potential in diagnosing vascular diseases, such as angiosclerosis, angiostenosis, or angiemphraxis.


2021 ◽  
Vol 5 (9) ◽  
pp. 210
Author(s):  
Steve B. Howell ◽  
Yue Shen ◽  
E. Furlan ◽  
Crystal L. Gnilka ◽  
Andrew W. Stephens
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document