spiral imaging
Recently Published Documents


TOTAL DOCUMENTS

67
(FIVE YEARS 5)

H-INDEX

21
(FIVE YEARS 2)

2021 ◽  
Author(s):  
Kyle M Gilbert ◽  
Paul Dubovan ◽  
Joseph S Gati ◽  
Ravi S Menon ◽  
Corey A Baron

Purpose: To develop an RF coil with an integrated commercial field camera for ultra-high field (7 T) neuroimaging. The RF coil will operate within a head-only gradient coil and be subject to the corresponding design constraints. The RF coil can thereafter be used for subject-specific correction of k-space trajectories-notably in gradient-sensitive sequences such as single-shot spiral imaging. Methods: The transmit and receive performance was evaluated before and after the integration of field probes, while field probes were evaluated when in an optimal configuration external to the coil and after their integration. Diffusion-weighted EPI and single-shot spiral acquisitions were employed to evaluate the efficacy of correcting higher order field perturbations and the consequent effect on image quality. Results: Field probes had a negligible effect on RF-coil performance, including the transmit efficiency, transmit uniformity, and mean SNR over the brain. Modest reductions in field-probe signal lifetimes were observed, caused primarily by non-idealities in the gradient and shim fields of the head-only gradient coil at the probe positions. The field monitoring system could correct up to second-order field perturbations in single-shot spiral imaging. Conclusion: The integrated RF coil and field camera was capable of concurrent field monitoring within a 7T head-only scanner and facilitated the subsequent correction of k-space trajectories during spiral imaging.


Author(s):  
Junjie Ma ◽  
Jun Chen ◽  
Galen D. Reed ◽  
Edward P. Hackett ◽  
Crystal E. Harrison ◽  
...  
Keyword(s):  

2019 ◽  
Author(s):  
Lars Kasper ◽  
Maria Engel ◽  
Jakob Heinzle ◽  
Matthias Mueller-Schrader ◽  
Nadine N. Graedel ◽  
...  

AbstractSpiral fMRI has been put forward as a viable alternative to rectilinear echo-planar imaging, in particular due to its enhanced average k-space speed and thus high acquisition efficiency. This renders spirals attractive for contemporary fMRI applications that require high spatiotemporal resolution, such as laminar or columnar fMRI. However, in practice, spiral fMRI is typically hampered by its reduced robustness and ensuing blurring artifacts, which arise from imperfections in both static and dynamic magnetic fields.Recently, these limitations have been overcome by the concerted application of an expanded signal model that accounts for such field imperfections, and its inversion by iterative image reconstruction. In the challenging ultra-high field environment of 7 Tesla, where field inhomogeneity effects are aggravated, both multi-shot and single-shot 2D spiral imaging at sub-millimeter resolution was demonstrated with high depiction quality and anatomical congruency.In this work, we further these advances towards a time series application of spiral readouts, namely, single-shot spiral BOLD fMRI at 0.8 mm in-plane resolution. We demonstrate that spiral fMRI at 7 T is not only feasible, but delivers both competitive image quality and BOLD sensitivity, with a spatial specificity of the activation maps that is not compromised by artifactual blurring. Furthermore, we show the versatility of the approach with a combined in/out spiral readout at a more typical resolution (1.5 mm), where the high acquisition efficiency allows to acquire two images per shot for improved sensitivity by echo combination.HighlightsThis work reports the first fMRI study at 7T with spiral readout gradient waveforms.We achieve spiral fMRI with sub-millimeter resolution (0.8 mm, in-plane FOV 230 mm), acquired in a single shot.Spiral images exhibit intrinsic geometric congruency to anatomical scans, and spatially highly specific activation patterns.Image reconstruction rests on a signal model expanded by measured trajectories and static field maps, inverted by cg-SENSE.We assess generalizability of the approach for spiral in/out readouts, providing two images per shot (1.5 mm resolution).


2019 ◽  
Vol 30 (2) ◽  
pp. 855-865 ◽  
Author(s):  
Tobias Greve ◽  
Nico Sollmann ◽  
Andreas Hock ◽  
Silke Hey ◽  
Velmurugan Gnanaprakasam ◽  
...  

2018 ◽  
Vol 80 (5) ◽  
pp. 1836-1846 ◽  
Author(s):  
Maria Engel ◽  
Lars Kasper ◽  
Christoph Barmet ◽  
Thomas Schmid ◽  
Laetitia Vionnet ◽  
...  
Keyword(s):  

2017 ◽  
Vol 20 (4) ◽  
pp. 1400-1412 ◽  
Author(s):  
H. Habibullah ◽  
H. R. Pota ◽  
I. R. Petersen

2017 ◽  
Vol 79 (6) ◽  
pp. 3218-3228 ◽  
Author(s):  
Dinghui Wang ◽  
Nicholas R. Zwart ◽  
James G. Pipe
Keyword(s):  

2017 ◽  
Vol 79 (5) ◽  
pp. 2597-2606 ◽  
Author(s):  
Ozkan Doganay ◽  
Tahreema N. Matin ◽  
Anthony Mcintyre ◽  
Brian Burns ◽  
Rolf F. Schulte ◽  
...  
Keyword(s):  

2016 ◽  
Vol 77 (1) ◽  
pp. 83-91 ◽  
Author(s):  
Bertram J. Wilm ◽  
Christoph Barmet ◽  
Simon Gross ◽  
Lars Kasper ◽  
S. Johanna Vannesjo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document