sequential measurement
Recently Published Documents


TOTAL DOCUMENTS

80
(FIVE YEARS 13)

H-INDEX

12
(FIVE YEARS 2)

2020 ◽  
Vol 125 (8) ◽  
Author(s):  
Hammad Anwer ◽  
Sadiq Muhammad ◽  
Walid Cherifi ◽  
Nikolai Miklin ◽  
Armin Tavakoli ◽  
...  

Quantum ◽  
2020 ◽  
Vol 4 ◽  
pp. 302
Author(s):  
Debashis Saha ◽  
Rafael Santos ◽  
Remigiusz Augusiak

Violation of a noncontextuality inequality or the phenomenon referred to `quantum contextuality' is a fundamental feature of quantum theory. In this article, we derive a novel family of noncontextuality inequalities along with their sum-of-squares decompositions in the simplest (odd-cycle) sequential-measurement scenario capable to demonstrate Kochen-Specker contextuality. The sum-of-squares decompositions allow us to obtain the maximal quantum violation of these inequalities and a set of algebraic relations necessarily satisfied by any state and measurements achieving it. With their help, we prove that our inequalities can be used for self-testing of three-dimensional quantum state and measurements. Remarkably, the presented self-testing results rely on weaker assumptions than the ones considered in Kochen-Specker contextuality.


2020 ◽  
Vol 19 (5) ◽  
Author(s):  
Amit Mukherjee ◽  
Arup Roy ◽  
Some Sankar Bhattacharya ◽  
Biswajit Paul ◽  
Kaushiki Mukherjee ◽  
...  

Micromachines ◽  
2019 ◽  
Vol 10 (9) ◽  
pp. 577 ◽  
Author(s):  
Yang Jun Kang

Aggregation of red blood cells (RBCs) varies substantially depending on changes of several factors such as hematocrit, membrane deformability, and plasma proteins. Among these factors, hematocrit has a strong influence on the aggregation of RBCs. Thus, while measuring RBCs aggregation, it is necessary to monitor hematocrit or, additionally, the effect of hematocrit (i.e., blood viscosity or pressure). In this study, the sequential measurement method of pressure and RBC aggregation is proposed by quantifying blood flow (i.e., velocity and image intensity) through a microfluidic device, in which an air-compressed syringe (ACS) is used to control the sample injection. The microfluidic device used is composed of two channels (pressure channel (PC), and blood channel (BC)), an inlet, and an outlet. A single ACS (i.e., air suction = 0.4 mL, blood suction = 0.4 mL, and air compression = 0.3 mL) is employed to supply blood into the microfluidic channel. At an initial time (t < 10 s), the pressure index (PI) is evaluated by analyzing the intensity of microscopy images of blood samples collected inside PC. During blood delivery with ACS, shear rates of blood flows vary continuously over time. After a certain amount of time has elapsed (t > 30 s), two RBC aggregation indices (i.e., SEAI: without information on shear rate, and erythrocyte aggregation index (EAI): with information on shear rate) are quantified by analyzing the image intensity and velocity field of blood flow in BC. According to experimental results, PI depends significantly on the characteristics of the blood samples (i.e., hematocrit or base solutions) and can be used effectively as an alternative to blood viscosity. In addition, SEAI and EAI also depend significantly on the degree of RBC aggregation. In conclusion, on the basis of three indices (two RBC aggregation indices and pressure index), the proposed method is capable of measuring RBCs aggregation consistently using a microfluidic device.


Sensors ◽  
2019 ◽  
Vol 19 (13) ◽  
pp. 2948 ◽  
Author(s):  
Seonho Kang ◽  
Junesol Song ◽  
Deokhwa Han ◽  
Bugyeom Kim ◽  
Hyoungmin So ◽  
...  

Earthquakes generate energy that propagates into the ionosphere and incurs co-seismic ionospheric disturbances (CIDs), which can be observed in ionospheric delay measurements. In most cases, the CID has a weak signal strength, because the energy in the atmosphere transferred from the earthquake dissipates as it travels toward the ionosphere. It is particularly hard to observe at reference stations that are located far from the epicenter. As the number of Global Navigation Satellite System stations and their positions are restricted, it is important to employ weak CID data in the analysis by improving the detection performance of CIDs. In this study, we suggest a new method of detecting CIDs, which mainly uses a sequential measurement combination of the carrier phase-based ionospheric delay data, with a 1-second interval. The proposed method’s performance was compared with conventional methods, including band-pass filters and a representative time-derivative method, using data from the 2011 Tohoku earthquake. As a result, the maximum CID-to-noise ratio can be increased by a maximum of 13% when the proposed method is used, and consequently, the detection performance of the CID can be improved.


2019 ◽  
Vol 37 ◽  
pp. e126
Author(s):  
M.A. Vieira Da Silva ◽  
L.A. Pertili Rodrigues De Rese ◽  
E.A. Mantovani Rodrigues De Re ◽  
A.P. Mendes Da Silva ◽  
M. Marchiori Vieira ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document