lumpectomy cavity
Recently Published Documents


TOTAL DOCUMENTS

116
(FIVE YEARS 13)

H-INDEX

18
(FIVE YEARS 1)

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Changhui Zhao ◽  
Jianbin Li ◽  
Wei Wang ◽  
Guanzhong Gong ◽  
Liang Xu ◽  
...  

Abstract Background The application of delayed-enhancement magnetic resonance (DE-MR) simulation imaging in lumpectomy cavity (LC) delineation for prone radiotherapy in patients with an invisible seroma or a low seroma clarity score (SCS) after breast-conserving surgery (BCS) based on deformable image registration (DIR) was assessed. Methods Twenty-six patients who were suitable for radiotherapy in prone positions after BCS were enrolled, and both computed tomography (CT) and DE-MR simulation scans were acquired. The LC delineated based on titanium surgical clips on CT images was denoted as LCCT. The LC delineated based on the signal of cavity boundaries on fat-suppressed T2-weighted imaging (T2WI) and multiphase delayed-enhancement T1-weighted imaging (DE-T1WI), which was performed at 2 min, 5 min and 10 min postinjection, were denoted as LCT2, LC2T1, LC5T1 and LC10T1, respectively. Afterwards, DIR was performed to compare the volumes and locations of the LCs with MIM software. The generalized conformity index (CIgen) of inter (intra) observer (Inter-CIgen and Intra-CIgen) was also used to explore the inter(intra) observer variation for LC delineation on each image modality. Results LCCT–LC10T1 provided the best conformal index (CI) and degree of inclusion (DI), increasing by 2.08% and 4.48% compared to LCCT–LCT2, 11.36% and 2.94% for LCCT–LC2T1, and 8.89% and 7.69% for LC5T1–LCCT, respectively. The center of mass (COM) of LCCT–LC10T1 decreased by 17.86%, 6.12% and 13.21% compared with that of LCCT–LCT2, LCCT–LC2T1 and LCCT–LC5T1, respectively. The agreement of LC delineation was strongest for 10th min DE-TIWI (coefficient of variation, COV = 2.30%, Inter-CIgen = 87.06%, Intra-CIgen = 92.64%). Conclusion For patients with a low SCS (SCS ≤ 2) after BCS, it is feasible to contour the LC based on prone DE-MR simulation images. Furthermore, the LC derived from prone DE-T1WI at 10 min was found to be most similar to that derived from prone CT simulation scans using titanium surgical clips regardless of the volume and location of the LC. Inter (intra) variability was minimal for the delineation of the LC based on 10th min DE-TIWI.


2021 ◽  
Author(s):  
changhui Zhao ◽  
Jianbin Li ◽  
Wei Wang ◽  
Guanzhong Gong ◽  
Liang Xu ◽  
...  

Abstract Background The application of delayed-enhancement magnetic resonance (DE-MR) simulation imaging in lumpectomy cavity (LC) delineation for prone radiotherapy in patients with an invisible seroma or a low seroma clarity score (SCS) after breast-conserving surgery (BCS) based on deformable image registration (DIR) was assessed. Methods Twenty-six patients who were suitable for radiotherapy in prone positions after BCS were enrolled, and both computed tomography (CT) and DE-MR simulation scans were acquired. The LC delineated based on titanium surgical clips on CT images was denoted as LCCT. The LC delineated based on the signal of cavity boundaries on fat-suppressed T2-weighted imaging (T2WI) and multiphase delayed-enhancement T1-weighted imaging (DE-T1WI), which was performed at 2 min, 5 min and 10 min postinjection, were denoted as LCT2, LC2T1, LC5T1 and LC10T1, respectively. Afterwards, DIR was performed to compare the volumes and locations of the LCs with MIM software. The generalized conformity index (CIgen) of inter (intra) observer (Inter-CIgen and Intra-CIgen) was also used to explore the inter(intra) observer variation for LC delineation on each image modality. Results LCCT-LC10T1 provided the best conformal index (CI) and degree of inclusion (DI), increasing by 2.08% and 4.48% compared to LCCT-LCT2, 11.36% and 2.94% for LCCT-LC2T1, and 8.89% and 7.69% for LC5T1-LCCT, respectively. The center of mass (COM) of LCCT-LC10T1 decreased by 17.86%, 6.12% and 13.21% compared with that of LCCT-LCT2, LCCT-LC2T1 and LCCT-LC5T1, respectively. The agreement of LC delineation was strongest for 10th min DE-TIWI (coefficient of variation, COV = 2.30%, Inter-CIgen = 87.06%, Intra-CIgen = 92.64%). Conclusion For patients with a low SCS (SCS ≤ 2) after BCS, it is feasible to contour the LC based on prone DE-MR simulation images. Furthermore, the LC derived from prone DE-T1WI at 10 min was found to be most similar to that derived from prone CT simulation scans using titanium surgical clips regardless of the volume and location of the LC. Inter(intra)variability was minimal for the delineation of the LC based on 10th min DE-TIWI.


Author(s):  
Ozlem Demircioglu ◽  
Huseyin Tepetam ◽  
Ayfer Ay Eren ◽  
Zerrin Ozgen ◽  
Fatih Demircioglu ◽  
...  

Background: Accurate localization of the lumpectomy cavity is important for breast cancer radiotherapy after breast-conserving surgery (BCS), but the LC localization based on CT is often difficult to delineate accurately. The study aimed to compare CT-defined LC planning to MRI-defined findings in the supine position for higher soft-tissue resolution of MRI. Methods: Fifty-nine breast cancer patients underwent radiotherapy CT planning in supine position followed by MR imaging on the same day. LC was contoured by the radiologist and radiation oncologist together by CT and MRI separately. T2 weighted MR images and tomography findings were combined and the LC volume, mean diameter and the longest axis length were measured after contouring. Subsequently, patients were divided into two groups according to seroma in LC and the above-mentioned parameters were compared. Results: We did not find any statistically significant difference in the LC volume, mean diameter and length at the longest axis between CT and MRI but based on the presence or absence of seroma, statistically significant differences were found in the LC volumes and the length at the longest axis of LC volumes. Conclusion: We believe that the supine MRI in the same position with CT will be more effective for radiotherapy planning, particularly in patients without a seroma in the surgical cavity.


2020 ◽  
Vol 27 (6) ◽  
pp. 1854-1861 ◽  
Author(s):  
Barbara L. Smith ◽  
Conor R. Lanahan ◽  
Michelle C. Specht ◽  
Bridget N. Kelly ◽  
Carson Brown ◽  
...  

Abstract Background Obtaining tumor-free margins is critical to prevent recurrence after lumpectomy for breast cancer. Unfortunately, current approaches leave positive margins that require second surgeries in 20–40% of patients. We assessed the LUM Imaging System for real-time, intraoperative detection of residual tumor. Methods Breast lumpectomy cavity walls and excised specimens were assessed with the LUM Imaging System after 1 mg/kg intravenous LUM015, a protease-activatable fluorescent agent. Fluorescence at potential sites of residual tumor in lumpectomy cavity walls was evaluated intraoperatively with a sterile hand-held probe, with real-time predictive results displayed on a monitor intraoperatively, and later correlated with histopathology. Results In vivo lumpectomy cavities and excised specimens were imaged after LUM015 injection in 45 women undergoing breast cancer surgery. Invasive ductal and lobular cancers and intraductal cancer (DCIS) were included. A total of 570 cavity margin surfaces in 40 patients were used for algorithm development. Image analysis and display took approximately 1 s per 2.6-cm-diameter circular margin surface. All breast cancer subtypes could be distinguished from adjacent normal tissue. For all imaged cavity surfaces, sensitivity for tumor detection was 84%. Among 8 patients with positive margins after standard surgery, sensitivity for residual tumor detection was 100%; 2 of 8 were spared second surgeries because additional tissue was excised at sites of LUM015 signal. Specificity was 73%, with some benign tissues showing elevated fluorescent signal. Conclusions The LUM015 agent and LUM Imaging System allow rapid identification of residual tumor in the lumpectomy cavity of breast cancer patients and may reduce rates of positive margins.


2019 ◽  
Vol 105 (1) ◽  
pp. S102-S103
Author(s):  
A. Kuczmarska-Haas ◽  
J.S. Witt ◽  
A. Burr ◽  
D.M. Francis ◽  
S.A. Rosenberg ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document