electromagnetic guidance
Recently Published Documents


TOTAL DOCUMENTS

47
(FIVE YEARS 6)

H-INDEX

11
(FIVE YEARS 0)

2021 ◽  
Vol 158 ◽  
pp. S49-S51
Author(s):  
A. Cantin ◽  
M. Lavallée ◽  
É. Poulin ◽  
W. Foster ◽  
L. Beaulieu

2021 ◽  
Vol 216 (4) ◽  
pp. 981-988
Author(s):  
Giuseppe Gullo ◽  
Anaïs Colin ◽  
Pierre Frossard ◽  
Anne Marie Jouannic ◽  
Jean François Knebel ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Namo Kim ◽  
Hyun Il Kim ◽  
Do-Hyeong Kim ◽  
Dahee Park ◽  
Sei Han Song ◽  
...  

Abstract Background Radial artery cannulation can cause complications such as haematoma formation or thrombosis due to its small diameter. Recently, a novel ultrasound device equipped with an electromagnetic guidance system was introduced, showing the path and alignment of the needle during the procedure. The aim of this study was to investigate the effects of this novel system on both success and complication rates during radial artery cannulation under ultrasound guidance. Methods In this randomized controlled trial, 76 adults scheduled for neurosurgery requiring radial artery cannulation were recruited. In group E (n = 38), radial artery cannulation was performed using the electromagnetic guidance ultrasound system, whereas in group C (n = 38), the procedure was performed using conventional ultrasound guidance. The success rates of cannulation on the first attempt, cannulation times, number of attempts, and incidence of complications were compared between the two groups. Results There was a significant difference in the success rates on the first attempt between the two groups (group C = 78.9% vs. group E = 94.7%, P = 0.042). Incidences of posterior wall puncture and haematoma formation (group C = 8 vs. group E = 1; P = 0.028) were significantly lower in group E than in group C. The median cannulation time for successful attempts was comparable between groups. Conclusions Use of the novel electromagnetic guidance system resulted in a better success rate on the first attempt and a lower incidence of complications during radial artery cannulation. Trial registration This study was registered at http://cris.nih.go.kr (registration number: KCT0002476).


2020 ◽  
Author(s):  
D Gröner ◽  
A Seitel ◽  
M Eisenmann ◽  
B Pekdemir ◽  
L. Aguilera Saiz ◽  
...  

2018 ◽  
Vol 53 ◽  
pp. 22
Author(s):  
Iris Naudin ◽  
Nellie Della Schiava ◽  
Richard Moreau ◽  
Arnaud Leleve ◽  
Minh Tu Pham ◽  
...  

2018 ◽  
Vol 20 (2) ◽  
pp. 128-133 ◽  
Author(s):  
Céline Monard ◽  
Mathilde Lefèvre ◽  
Fabien Subtil ◽  
Vincent Piriou ◽  
Jean-Stephane David

Objectives: To confirm the feasibility of intracavitary electrocardiogram guidance to verify tip’s position during insertion of peripherally inserted central catheter and to identify clinical factors or intracavitary electrocardiogram patterns associated with aberrant tip’s position. Methods: A prospective study was conducted in our university hospital after authorization of the ethics committee. All patients addressed for peripherally inserted central catheter insertion were included and received the insertion using intracavitary electrocardiogram and electromagnetic guidance. Side of insertion and three electrocardiogram factors were collected: visualization of P-wave at baseline (sinusal rhythm), acquisition of the maximal P-wave and the negative deflection. All patients had a systematic post-procedural chest X-ray. One of the investigators assessed all chest X-ray, blinded to the results of intracavitary electrocardiogram, and confirmed whether the tip’s position on chest X-ray matched with the intracavitary electrocardiogram information or if the tip was malpositioned on chest X-ray (mismatch with intracavitary electrocardiogram or aberrant position). Factors associated with malposition were described. Results: From January 2015 to April 2015, 330 patients were eligible, 5 had an uninterpretable chest X-ray, and 14 were non-sinusal at baseline. Our main analysis population included 311 patients. We observed a mismatch between intracavitary electrocardiogram and chest X-ray estimate of the tip’s position in 3 cases (1%) and an aberrant tip’s position occurred in 3 cases (1%). Incidence of malposition was higher in the group of patients with non-sinusal rhythm (14%) and when the catheter was inserted on the left side (7%). Conclusion: This study confirmed the feasibility of intracavitary electrocardiogram for peripherally inserted central catheter positioning and the limits of chest X-ray. Insertion on left side may represent risk factor for aberrant position but our study lacked power to establish a statistical link.


Author(s):  
Fernanda Mantuan Dala Rosa de Oliveira ◽  
Ismael Chiamenti ◽  
José Luís Fabris ◽  
Marcia Muller ◽  
Hypolito José Kalinowski

Sign in / Sign up

Export Citation Format

Share Document