cochlear duct length
Recently Published Documents


TOTAL DOCUMENTS

50
(FIVE YEARS 35)

H-INDEX

7
(FIVE YEARS 2)

Author(s):  
Flavia Di Maro ◽  
Marco Carner ◽  
Andrea Sacchetto ◽  
Davide Soloperto ◽  
Daniele Marchioni

Abstract Purpose The aim of this study is to evaluate speech perception outcomes after a frequency reallocation performed through the creation of an anatomically based map obtained with Otoplan®, a tablet-based software that allows the cochlear duct length to be calculated starting from CT images. Methods Ten postlingually deafened patients who underwent cochlear implantation with MED-EL company devices from 2015 to 2019 in the Tertiary referral center University Hospital of Verona have been included in a retrospective study. The postoperative CT scans were evaluated with Otoplan®; the position of the intracochlear electrodes was obtained, an anatomical mapping was carried out and then it was submitted to the patients. All patients underwent pure tonal and speech audiometry before and after the reallocation and the audiological results were processed considering the Speech Recognition Threshold (SRT), the Speech Awareness Threshold (SAT) and the Pure Tone Average (PTA). The differences in the PTA, SAT and SRT values before and after the reallocation were determined. The results were statistically processed using the software Stata with a significance value of α < 0.05. Results The mean values of SRT (61.25 dB versus 51.25 dB) and SAT (49 dB versus 41 dB) were significantly lower (p: 0.02 and p: 0.04, respectively) after the reallocation. No significant difference was found between PTA values (41.5 dB versus 39.25 dB; p: 0.18). Conclusions Our preliminary results demonstrate better speech discrimination and rapid adaptation in implanted postlingually deaf patients after anatomic mapping and subsequent frequency reallocation.


Author(s):  
M.B. Eser ◽  
B. Atalay ◽  
M.B. Dogan ◽  
N. Gündüz ◽  
M.T. Kalcioglu

Author(s):  
Shayna P. Cooperman ◽  
Ksenia A. Aaron ◽  
Ayman Fouad ◽  
Emma Tran ◽  
Nikolas H. Blevins ◽  
...  

Author(s):  
Tabita Breitsprecher ◽  
Anandhan Dhanasingh ◽  
Marko Schulze ◽  
Markus Kipp ◽  
Rami Abu Dakah ◽  
...  

Abstract Objectives Knowledge about cochlear duct length (CDL) may assist electrode choice in cochlear implantation (CI). However, no gold standard for clinical applicable estimation of CDL exists. The aim of this study is (1) to determine the most reliable radiological imaging method and imaging processing software for measuring CDL from clinical routine imaging and (2) to accurately predict the insertion depth of the CI electrode. Methods Twenty human temporal bones were examined using different sectional imaging techniques (high-resolution computed tomography [HRCT] and cone beam computed tomography [CBCT]). CDL was measured using three methods: length estimation using (1) a dedicated preclinical 3D reconstruction software, (2) the established A-value method, and (3) a clinically approved otosurgical planning software. Temporal bones were implanted with a 31.5-mm CI electrode and measurements were compared to a reference based on the CI electrode insertion angle measured by radiographs in Stenvers projection (CDLreference). Results A mean cochlear coverage of 74% (SD 7.4%) was found. The CDLreference showed significant differences to each other method (p < 0.001). The strongest correlation to the CDLreference was found for the otosurgical planning software-based method obtained from HRCT (CDLSW-HRCT; r = 0.87, p < 0.001) and from CBCT (CDLSW-CBCT; r = 0.76, p < 0.001). Overall, CDL was underestimated by each applied method. The inter-rater reliability was fair for the CDL estimation based on 3D reconstruction from CBCT (CDL3D-CBCT; intra-class correlation coefficient [ICC] = 0.43), good for CDL estimation based on 3D reconstruction from HRCT (CDL3D-HRCT; ICC = 0.71), poor for CDL estimation based on the A-value method from HRCT (CDLA-HRCT; ICC = 0.29), and excellent for CDL estimation based on the A-value method from CBCT (CDLA-CBCT; ICC = 0.87) as well as for the CDLSW-HRCT (ICC = 0.94), CDLSW-CBCT (ICC = 0.94) and CDLreference (ICC = 0.87). Conclusions All approaches would have led to an electrode choice of rather too short electrodes. Concerning treatment decisions based on CDL measurements, the otosurgical planning software-based method has to be recommended. The best inter-rater reliability was found for CDLA-CBCT, for CDLSW-HRCT, for CDLSW-CBCT, and for CDLreference. Key Points • Clinically applicable calculations using high-resolution CT and cone beam CT underestimate the cochlear size. • Ten percent of cochlear duct length need to be added to current calculations in order to predict the postoperative CI electrode position. • The clinically approved otosurgical planning software-based method software is the most suitable to estimate the cochlear duct length and shows an excellent inter-rater reliability.


Author(s):  
Mehmet Bilgin Eser ◽  
Basak Atalay ◽  
Mahmut Bilal Dogan ◽  
Nesrin Gündüz ◽  
Mahmut Tayyar Kalcioglu

OTO Open ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 2473974X2110453
Author(s):  
Johannes Taeger ◽  
Franz Tassilo Müller-Graff ◽  
Lukas Ilgen ◽  
Phillip Schendzielorz ◽  
Rudolf Hagen ◽  
...  

Objective Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). Study Design Retrospective data analyses of 42 cochleae. Setting Tertiary care medical center. Methods Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. Results CDL values were significantly shorter in MRI by MPR ( d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR ( d = 1.67 mm) and ECA ( d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI ( d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). Conclusion In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established.


2021 ◽  
Author(s):  
Björn Spahn ◽  
L Ilgen ◽  
Franz-Tassilo Müller-Graff ◽  
P Schendzielorz ◽  
J Taeger ◽  
...  