light depolarization
Recently Published Documents


TOTAL DOCUMENTS

48
(FIVE YEARS 4)

H-INDEX

10
(FIVE YEARS 0)

Molecules ◽  
2021 ◽  
Vol 26 (21) ◽  
pp. 6601
Author(s):  
Joanna Bojda ◽  
Ewa Piorkowska ◽  
Grzegorz Lapienis ◽  
Adam Michalski

The influence of macromolecular architecture on shear-induced crystallization of poly(L-lactide) (PLLA) was studied. To this aim, three star PLLAs, 6-arm with Mw of 120 and 245 kg/mol, 4-arm with Mw of 123 kg/mol, and three linear PLLAs with Mw of 121, 240 and 339 kg/mol, were synthesized and examined. The PLLAs were sheared at 170 and 150 °C, at 5/s, 10/s and 20/s for 20 s, 10 s and 5 s, respectively, and then cooled at 10 or 30 °C/min. Shear-induced crystallization during cooling was followed by a light depolarization method, whereas the crystallized specimens were examined by DSC, 2D-WAXS, 2D-SAXS and SEM. The effect of shear depended on the shearing conditions, cooling rate and polymer molar mass but it was also affected by the macromolecular architecture. The shear-induced crystallization of linear PLLA with Mw of 240 kg/mol was more intense than that of the 6-arm polymer with similar Mw, most possibly due to its higher Mz. However, the influence of shear on the crystallization of the star polymers with Mw close to 120 kg/mol was stronger than on that of their linear analog. This was reflected in higher crystallization temperature, as well as crystallinity achieved during cooling.


2020 ◽  
Vol 59 (36) ◽  
pp. 11301
Author(s):  
Kang Zou ◽  
Lijun Miao ◽  
Guofa Wang ◽  
Ran Bi ◽  
Kan Chen ◽  
...  

2016 ◽  
Vol 11 (3) ◽  
Author(s):  
Soad Fadlalla Ali ◽  
Sajid Jamil ◽  
Muhammad Naveed Akhtar ◽  
Muhammad Farooq

Objective: To compare the automated detection of malaria with microscopy. Methods: In this study 250 blood samples submitted for malaria investigation were studied microscopically for malaria parasites. All samples were additionally analyzed for same parameters with automated hematology analyzer, Cell Dyn 3700 (CD3700). The results from the instrument generated as scatter plots (derived by laser light depolarization), were compared with microscopy results. Results: The atypical depolarizing events or positive patterns were observed in 43 out of 250 samples on cell Dyn 3700, while microscopically 3 7 samples were found to b e positive. Three samples positive on microscopy, were found t o b e negative on CD-3700. Compared with microscopy the sensitivity of CD3700 was 92.5% and specificity was 97.3%. Maximum parasitaemia was 6.5%. Conclusions: Automated detection of malaria by CD3700 automated hematology analyzer is feasible for screening purpose in malaria endemic and non-endemic areas.


Author(s):  
D.A. Zimnyakov ◽  
R.A. Zdrajevsky ◽  
S.A. Yuvchenko ◽  
O.V. Ushakova ◽  
O.V. Angelsky ◽  
...  

2015 ◽  
Vol 87 (5) ◽  
pp. 437-445 ◽  
Author(s):  
Maria Rebelo ◽  
Carolina Tempera ◽  
Claudia Bispo ◽  
Claudia Andrade ◽  
Rui Gardner ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document