Praci Institutu elektrodinamiki Nacionalanoi akademii nauk Ukraini
Latest Publications


TOTAL DOCUMENTS

227
(FIVE YEARS 120)

H-INDEX

3
(FIVE YEARS 2)

Published By Co. Ltd. Ukrinformnauka

1727-9895

Author(s):  
B.A. Kromplyas ◽  
◽  
A.S. Levytskyi ◽  
Ie.O. Zaitsev ◽  
◽  
...  

In this paper smart shield panel electrical operating parameters meters of energy generating facilities functionality is analysis. The list of functions of measuring instruments supplemented, which allowed increasing their operational characteristics. Methods and results of realization of these functions given for the panel board intellectualized voltage meter of alternating current. The structural scheme of the developed panel board intellectualized meter is described and its main technical characteristics are given.A method of mobile calibration of the device is proposed, in which a calibration signal source with a separate fixed value is used, and the calibration process itself is controlled from the device keyboard. A modernized detailed and simplified calibration algorithm is present. Ref. 12, fig. 5, tabl. 2.


Author(s):  
P.V. Shymaniuk ◽  
◽  
V.O. Miroshnyk ◽  

A comparative analysis of clustering methods was performed to identify gaps and anomalous values in the data. Data from the northwestern region of the United States were used for evaluation. According to the analysis results, it was found that the use of the DBSCAN method leads to a much smaller number of false positives. An algorithm for two-stage data validation using clustering and time series decomposition methods is proposed. Ref.9, fig. 3, tables 3.


Author(s):  
V.O. Bereka ◽  
◽  
I.P. Kondratenko ◽  

A technique for calculating the parameters of a magnetic switch as an element of a generator of short high-voltage pulses of tension to coordinate its compatible work with a water treatment chamber by dint of pulse barrier discharge is shown. The expediency and efficiency of using such a switch as an element that, by shunting, the discharge chamber, discharges the barrier to the arrival of the next voltage pulse has been confirmed. It is proved that with the accepted geometrical dimensions of the discharge chamber and the amplitude of the pulse voltage, provided that the magnetic switch is present that it is possible to increase the practical use of electricity by ~ 40% due to that which was accumulated in the dielectric barrier in one discharge. Ref.10, fig. 5.


Author(s):  
I.V. Volkov ◽  
◽  
V.V. Golubev ◽  
V.I. Zozulev ◽  
◽  
...  

The article considers the properties of the most commonly used two-and multilevel inverter topologies used in systems for converting electricity from several primary power sources into the required high-quality output voltage for low-voltage networks and high-voltage consumers. However, a common disadvantage of most known multilevel converters is the increasing complexity of power structures, an increase in the number of primary power sources, power elements, and the cost of devices as the number of their voltage levels increases. Two schemes of alternative three-level autonomous voltage inverters with a high-frequency autotransformer with a midpoint and an example of constructing their digital control system are proposed. The analysis of their work on PSpice models in the OrCAD design system is carried out. The possibility of obtaining six voltage sublevels with fewer power elements and increased output voltage quality is shown, compared to the corresponding cascade multilevel inverters. The advantages and applications of autotransformer bridge voltage inverters in terms of energy and functionality compared to well-known multilevel inverters are presented. Ref. 8, fig. 7.


Author(s):  
V.V. Kuchanskyy ◽  
◽  
O.V. Savytskyi ◽  

The self-excitation phenomenon of generators connected to an unloaded power line is considered. Accordingly, the selected values of the conductivity of the controlled shunt reactors, following the control range (especially in the overload mode), avoid the occurrence of self-excitation of the generators. The physical analysis of the processes occurring at self-excitation of the synchronous generator is given, and the calculated models are developed. It is established that in the case of artificial support along the entire length of the voltage line at the nominal value using controlled compensating devices, the transmission will have properties characteristic of relatively short lines (up to 500 km) regardless of its geometric length. It is determined that the length of the line section at the ends of which the DC voltage is maintained is much less than 500 km. Therefore, less than the natural voltage along the section length will exceed the nominal value at the transmitted power, and the line will have excess reactive power. Consumption in intermediate compensation devices (compensation current must be inductive). Ref.8, fig. 4, tables 4.


Author(s):  
A.A. Shcherba ◽  
◽  
O.D. Podoltsev ◽  
Y.V. Peretiatko ◽  
V.M. Zolotarov ◽  
...  

Based on the theory of thermal circuits, a computer model of an induction channel furnace has been developed, which is used to obtain industrial copper wire rods in the mode of continuous casting. The model allows calculating the established electrothermal processes considering the flows of cold and molten metal in its core. In the developed thermal model, it is proposed to consider the convection fluxes of heat in the metal using controlled current sources. The temperature distribution in the active zone of the channel furnace is calculated, and the influence of the mass flow of metal at the inlet and outlet of the furnace on the non-uniformity of temperature distribution in the active zone is shown. The obtained results allow determining the required electric power of the furnace at different values ​​of the flow rate of the metal that moves continuously through its core while heating to a given temperature. The developed model is relatively easy to implement, using the Matlab/Simulink package, and allows online to estimate the melt temperature in different zones depending on the electric power consumed by the furnace and the metal consumption at the outlet of the furnace, as well as to determine rational modes of its operation. Ref. 7, fig. 4.


Author(s):  
I.M. Kucheriava ◽  

In the article, the magnetic and thermal field distributions generated by underground two-circuit extra-high voltage power cable line in the environment, particularly near the cables and flat aluminum shield, which is located at a different distance from the cables and has different thicknesses, are analyzed. The unique features of the magnetic field and temperature distributions inside the shield are computed and studied. For the cases under consideration, the Joule losses in the external shield do not exceed 3% of the losses in the cables. The primary electromagnetic characteristics are compared for the aluminum shield (shielding efficiency is 1,94) and the shield with lower conductivity (shielding efficiency is equal to 1,2). As shown, the thicker shield helps to increase the ampacity of the cable line owing to lower heating. The actual operating current of the cable line under consideration depends on the distance of the shield from the cables owing to the relation between their maximum temperature and this distance. Ref. 15, fig. 7, table.


Author(s):  
M.S. Seheda ◽  
◽  
O.M. Ravlyk ◽  
Z.M. Bakhor ◽  
A.Ya. Yatseyko ◽  
...  

The results of the study of overvoltages during arc single-phase earth faults of intermittent nature in the 35 kV electric network with isolated neutral are presented. Computer simulations of transients in the electrical network have obtained the maximum multiplicities of overvoltages at the point of occurrence of single-phase arc earth faults, which exceed theoretically expected according to known theories of the occurrence and development of overvoltages. The change of the overvoltage level on the 35 kV busbars of the network substations, electrically connected to the place of occurrence of the single-phase earth fault, and the influence of the cable line on the overvoltage multiplicity are shown. Ref. 12, fig. 3, table.


Author(s):  
E.V. Parus ◽  
◽  
I.V. Blinov ◽  
D.O. Olefir ◽  
◽  
...  

The article presents a simulation model for estimating the economic effect of the energy storage systems providing the balancing electricity to the Transmission System Operator in the balancing market segment. The model simulates the serial charge and discharge of storage (i.e., sequential provision of unloading and loading services). Peculiarities of considering the cost of purchase, installation, and maintenance of energy storage systems with reduction both to the guaranteed service life and the guaranteed resource of charge/discharge cycles are given. An example of the application of the simulation model for estimating the economic effect and payback period of energy storage systems in the provision of electricity balancing services in the balancing market segment is shown. Ref. 15.


Author(s):  
A.A. Shcherba ◽  
◽  
A.D. Podoltsev ◽  
I.M. Kucheriava ◽  
V.M. Zolotarev ◽  
...  

The model for the computation of thermal processes in induction heating installations with moving ingots is developed using equivalent thermal circuits. The controlled current sources as additional elements in the model are used to take into account the convective heat transfer along the moving ingot. The model is implemented in the program Matlab/Simulink and makes it possible to determine the temperature distribution along the ingot under steady-state heating conditions. The results are compared with data obtained by the alternative method which is based on the electromagnetic and thermal field theory and realized in the Comsol program. As shown the computational results by two methods concerning the temperature distribution along the ingot are in good agreement. The existing advantages and shortcomings of the used approaches are discussed. Ref. 8, fig. 3, table.


Sign in / Sign up

Export Citation Format

Share Document