inversion pulse
Recently Published Documents


TOTAL DOCUMENTS

84
(FIVE YEARS 10)

H-INDEX

14
(FIVE YEARS 1)

2022 ◽  
Vol 24 (1) ◽  
Author(s):  
Rui Guo ◽  
Hossam El-Rewaidy ◽  
Salah Assana ◽  
Xiaoying Cai ◽  
Amine Amyar ◽  
...  

Abstract Purpose To develop and evaluate MyoMapNet, a rapid myocardial T1 mapping approach that uses fully connected neural networks (FCNN) to estimate T1 values from four T1-weighted images collected after a single inversion pulse in four heartbeats (Look-Locker, LL4). Method We implemented an FCNN for MyoMapNet to estimate T1 values from a reduced number of T1-weighted images and corresponding inversion-recovery times. We studied MyoMapNet performance when trained using native, post-contrast T1, or a combination of both. We also explored the effects of number of T1-weighted images (four and five) for native T1. After rigorous training using in-vivo modified Look-Locker inversion recovery (MOLLI) T1 mapping data of 607 patients, MyoMapNet performance was evaluated using MOLLI T1 data from 61 patients by discarding the additional T1-weighted images. Subsequently, we implemented a prototype MyoMapNet and LL4 on a 3 T scanner. LL4 was used to collect T1 mapping data in 27 subjects with inline T1 map reconstruction by MyoMapNet. The resulting T1 values were compared to MOLLI. Results MyoMapNet trained using a combination of native and post-contrast T1-weighted images had excellent native and post-contrast T1 accuracy compared to MOLLI. The FCNN model using four T1-weighted images yields similar performance compared to five T1-weighted images, suggesting that four T1 weighted images may be sufficient. The inline implementation of LL4 and MyoMapNet enables successful acquisition and reconstruction of T1 maps on the scanner. Native and post-contrast myocardium T1 by MOLLI and MyoMapNet was 1170 ± 55 ms vs. 1183 ± 57 ms (P = 0.03), and 645 ± 26 ms vs. 630 ± 30 ms (P = 0.60), and native and post-contrast blood T1 was 1820 ± 29 ms vs. 1854 ± 34 ms (P = 0.14), and 508 ± 9 ms vs. 514 ± 15 ms (P = 0.02), respectively. Conclusion A FCNN, trained using MOLLI data, can estimate T1 values from only four T1-weighted images. MyoMapNet enables myocardial T1 mapping in four heartbeats with similar accuracy as MOLLI with inline map reconstruction.


Author(s):  
Markus Henningsson ◽  
Carl-Johan Carlhäll ◽  
Tino Ebbers ◽  
Johan Kihlberg

Abstract Objective To evaluate systolic flow-sensitive alternating inversion recovery (FAIR) during rest and exercise stress using 2RR (two cardiac cycles) or 1RR intervals between inversion pulse and imaging. Materials and methods 1RR and 2RR FAIR was implemented on a 3T scanner. Ten healthy subjects were scanned during rest and stress. Stress was performed using an in-bore ergometer. Heart rate, mean myocardial blood flow (MBF) and temporal signal-to-noise ratio (TSNR) were compared using paired t tests. Results Mean heart rate during stress was higher than rest for 1RR FAIR (85.8 ± 13.7 bpm vs 63.3 ± 11.1 bpm; p < 0.01) and 2RR FAIR (83.8 ± 14.2 bpm vs 63.1 ± 10.6 bpm; p < 0.01). Mean stress MBF was higher than rest for 1RR FAIR (2.97 ± 0.76 ml/g/min vs 1.43 ± 0.6 ml/g/min; p < 0.01) and 2RR FAIR (2.8 ± 0.96 ml/g/min vs 1.22 ± 0.59 ml/g/min; p < 0.01). Resting mean MBF was higher for 1RR FAIR than 2RR FAIR (p < 0.05), but not during stress. TSNR was lower for stress compared to rest for 1RR FAIR (4.52 ± 2.54 vs 10.12 ± 3.69; p < 0.01) and 2RR FAIR (7.36 ± 3.78 vs 12.41 ± 5.12; p < 0.01). 2RR FAIR TSNR was higher than 1RR FAIR for rest (p < 0.05) and stress (p < 0.001). Discussion We have demonstrated feasibility of systolic FAIR in rest and exercise stress. 2RR delay systolic FAIR enables non-contrast perfusion assessment during stress with relatively high TSNR.


2021 ◽  
Vol 8 ◽  
Author(s):  
W. Trent Franks ◽  
Ben P. Tatman ◽  
Jonah Trenouth ◽  
Józef R. Lewandowski

Order parameters are a useful tool for quantifying amplitudes of molecular motions. Here we measure dipolar order parameters by recoupling heteronuclear dipole-dipole couplings under fast spinning. We apply symmetry based recoupling methods to samples spinning under magic angle at 60 kHz by employing a variable flip angle compound inversion pulse. We validate the methods by measuring site-specific 15N-1H order parameters of a microcrystalline protein over a small temperature range and the same protein in a large, precipitated complex with antibody. The measurements of the order parameters in the complex are consistent with the observed protein undergoing overall motion within the assembly.


2021 ◽  
Author(s):  
Markus Henningsson ◽  
Carl-Johan Carlhäll ◽  
Tino Ebbers ◽  
Johan Kihlberg

Abstract Objective: To evaluate systolic flow-sensitive alternating inversion recovery (FAIR) during rest and exercise stress using 2RR (two cardiac cycles) or 1RR intervals between inversion pulse and imaging. Materials and Methods: 1RR and 2RR FAIR was implemented on a 3T scanner. Ten healthy subjects were scanned during rest and stress. Stress was performed using an in-bore ergometer. Heart rate, mean myocardial blood flow (MBF) and temporal signal-to-noise ratio (TSNR) were compared using paired t-tests. Results: Mean heart rate during stress was higher than rest for 1RR FAIR (85.8±13.7bpm vs 63.3±11.1bpm; p<0.01) and 2RR FAIR (83.8±14.2bpm vs 63.1±10.6bpm; p<0.01). Mean stress MBF was higher than rest for 1RR FAIR (2.97±0.76ml/g/min vs 1.43±0.6 ml/g/min; p<0.01) and 2RR FAIR (2.8±0.96 ml/g/min vs 1.22±0.59 ml/g/min; p<0.01). Resting mean MBF was higher for 1RR FAIR than 2RR FAIR (p<0.05), but not during stress. TSNR was lower for stress compared to rest for 1RR FAIR (4.52±2.54 vs 10.12±3.69; p<0.01) and 2RR FAIR (7.36±3.78 vs 12.41±5.12; p<0.01). 2RR FAIR TSNR was higher than 1RR FAIR for rest (p<0.05) and stress (p<0.001). Discussion: We have demonstrated feasibility of systolic FAIR in rest and exercise stress. 2RR delay systolic FAIR enables non-contrast perfusion assessment during stress with relatively high TSNR.


2021 ◽  
Vol 51 (5) ◽  
pp. 840-846
Author(s):  
Franz Wolfgang Hirsch ◽  
Jens Frahm ◽  
Ina Sorge ◽  
Christian Roth ◽  
Dirk Voit ◽  
...  

AbstractThe recent development of highly undersampled radial gradient echo sequences in combination with nonlinear inverse image reconstruction now allows for MRI examinations in real time. Image acquisition times as short as 20 ms yield MRI videos with rates of up to 50 frames per second with spin density, T1- and T2-type contrast. The addition of an initial 180° inversion pulse achieves accurate T1 mapping within only 4 s. These technical advances promise specific advantages for studies of infants and young children by eliminating the need for sedation or anesthesia. Our preliminary data demonstrate new diagnostic opportunities ranging from dynamic studies of speech and swallowing processes and body movements to a rapid volumetric assessment of brain cerebrospinal fluid spaces in only few seconds. Real-time MRI of the heart and blood flow can be performed without electrocardiogram gating and under free breathing. The present findings support the idea that real-time MRI will complement existing methods by providing long-awaited diagnostic options for patients in early childhood. Major advantages are the avoidance of sedation or anesthesia and the yet unexplored potential to gain insights into arbitrary body functions.


2019 ◽  
Vol 33 (1) ◽  
pp. 95-102 ◽  
Author(s):  
Junji Takahashi ◽  
Yuki Ohmoto-Sekine ◽  
Takashi Yoshida ◽  
Mitsue Miyazaki

Abstract Objective We evaluated image quality differences between axial and coronal non-contrast-enhanced renal three-dimensional (3D) magnetic resonance angiography (MRA) acquisitions, using time-spatial labeling inversion pulse (Time-SLIP) with flow-in balanced steady-state free precession (bSSFP). Materials and methods Axial and coronal images were acquired in 128 subjects using non-contrast-enhanced 3D-MRA with Time-SLIP flow-in bSSFP on a clinical 1.5-T MRI system. Visualization of source and maximum intensity projection (MIP) images of renal arteries were compared between the axial and coronal acquisitions using a four-point scale. For quantitative analysis, vessel-to-background contrast ratios of aorta and renal arteries were calculated. Results Both acquisitions yielded similarly excellent quality. In source image evaluation, coronal acquisitions showed significantly more motion degradation (p < 0.01) than did axial acquisitions. In MIP image evaluation, coronal acquisitions yielded superior image quality, less motion degradation, and better visualization of the number of renal branches than did axial acquisition. The renal artery to background signal contrast was greater in coronal than in axial acquisitions (p < 0.01). Conclusion Coronal acquisition provides superior contrast between the renal arteries and background and allows more persistent visualization than axial acquisitions in non-contrast-enhanced MRA using flow-in bSSFP with Time-SLIP. First-line screening of renal non-contrast-enhanced MRA should involve coronal acquisition.


Author(s):  
Amr Ahmed Mubarak ◽  
Ghada Elsaed Awad ◽  
Mohamed Adel Eltomey ◽  
Mahmoud Abd Elaziz Dawoud

Abstract Background To study the ability of non-contrast MR portography using time-spatial labeling inversion pulse (T-SLIP) as a non-invasive contrast-free imaging modality to delineate different portal vein pathological conditions. The study included 25 patients with known history of portal vein disease and another 25 age-matched patients with normal portal vein. Both groups were examined by respiratory-triggered non-contrast MR portography using time-spatial labeling inversion pulse technique. Image quality was assessed first, and findings of diagnostic scans were compared to color duplex ultrasonography and selectively in those with diseased portal vein to portal-phase images of dynamic contrast-enhanced MRI. Results Significant relation was found between breathing regularity and image quality in T-SLIP sequence, with diagnostic scans sensitivity and specificity of 89.29% and 86.21%, respectively, for diagnosis of different portal vein pathological conditions. Conclusions Non-contrast MR portography is a useful technique for diagnosis of portal vein pathology in carefully selected patients.


Sign in / Sign up

Export Citation Format

Share Document