scholarly journals Device for respiration activity measurement enables the determination of oxygen transfer rates of microbial cultures in shaken 96‐deepwell microtiter plates

Author(s):  
Robert Dinger ◽  
Clemens Lattermann ◽  
David Flitsch ◽  
Jan P. Fischer ◽  
Udo Kosfeld ◽  
...  
2000 ◽  
Vol 66 (6) ◽  
pp. 2641-2646 ◽  
Author(s):  
Wouter A. Duetz ◽  
Lorenz Rüedi ◽  
Robert Hermann ◽  
Kevin O'Connor ◽  
Jochen Büchs ◽  
...  

ABSTRACT Miniaturized growth systems for heterogeneous culture collections are not only attractive in reducing demands for incubation space and medium but also in making the parallel handling of large numbers of strains more practicable. We report here on the optimization of oxygen transfer rates in deep-well microtiter plates and the development of a replication system allowing the simultaneous and reproducible sampling of 96 frozen glycerol stock cultures while the remaining culture volume remains frozen. Oxygen transfer rates were derived from growth curves of Pseudomonas putida and from rates of oxygen disappearance due to the cobalt-catalyzed oxidation of sulfite. Maximum oxygen transfer rates (38 mmol liter−1 h−1, corresponding to a mass transfer coefficient of 188 h−1) were measured during orbital shaking at 300 rpm at a shaking diameter of 5 cm and a culture volume of 0.5 ml. A shaking diameter of 2.5 cm resulted in threefold-lower values. These high oxygen transfer rates allowed P. putida to reach a cell density of approximately 9 g (dry weight) liter−1 during growth on a glucose mineral medium at culture volumes of up to 1 ml. The growth-and-replication system was evaluated for a culture collection consisting of aerobic strains, mainly from the generaPseudomonas, Rhodococcus, andAlcaligenes, using mineral media and rich media. Cross-contamination and excessive evaporation during vigorous aeration were adequately prevented by the use of a sandwich cover of spongy silicone and cotton wool on top of the microtiter plates.


1983 ◽  
Vol 50 (02) ◽  
pp. 563-566 ◽  
Author(s):  
P Hellstern ◽  
K Schilz ◽  
G von Blohn ◽  
E Wenzel

SummaryAn assay for rapid factor XIII activity measurement has been developed based on the determination of the ammonium released during fibrin stabilization. Factor XIII was activated by thrombin and calcium. Ammonium was measured by an ammonium-sensitive electrode. It was demonstrated that the assay procedure yields accurate and precise results and that factor XIII-catalyzed fibrin stabilization can be measured kinetically. The amount of ammonium released during the first 90 min of fibrin stabilization was found to be 7.8 ± 0.5 moles per mole fibrinogen, which is in agreement with the findings of other authors. In 15 normal subjects and in 15 patients suffering from diseases with suspected factor XIII deficiency there was a satisfactory correlation between the results obtained by the “ammonium-release-method”, Bohn’s method, and the immunological assay (r1 = 0.65; r2= 0.70; p<0.01). In 3 of 5 patients with paraproteinemias the values of factor XIII activity determined by the ammonium-release method were markedly lower than those estimated by the other methods. It could be shown that inhibitor mechanisms were responsible for these discrepancies.


1974 ◽  
Author(s):  
S. Koncar-Djurdjevic ◽  
M. Mitrovic ◽  
S. Cvijovic ◽  
G. Popovic ◽  
Dimitrije Voronjec

Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1566
Author(s):  
Elena Fabris ◽  
Michela Bulfoni ◽  
Alessandro Nencioni ◽  
Emanuele Nencioni

Introduction: Alpha-galactosidase (α-Gal) is an enzyme responsible for the hydrolyzation of glycolipids and glycoprotein commonly found in dietary sources. More than 20% of the general population suffers from abdominal pain or discomfort caused by intestinal gas and by indigested or partially digested food residuals. Therefore, α-Gal is used in dietary supplements to reduce intestinal gases and help complex food digestion. Marketed enzyme-containing dietary supplements must be produced in accordance with the Food and Drug Administration (FDA) regulations for Current Good Manufacturing Practice (cGMPs). Aim: in this work we illustrated the process used to develop and validate a spectrophotometric enzymatic assay for α-Gal activity quantification in dietary supplements. Methods: The validation workflow included an initial statistical-phase optimization of materials, reagents, and conditions, and subsequently a comparative study with another fluorimetric assay. A final validation of method performance in terms of specificity, linearity, accuracy, intermediate-precision repeatability, and system precision was then executed. Results and conclusions: The proven method achieved good performance in the quantitative determination of α-Gal activity in commercial food supplements in accordance with the International Council for Harmonisation of Technical Requirements for Pharmaceuticals (ICH) guidelines and is suitable as a rapid in-house quality control test.


Sign in / Sign up

Export Citation Format

Share Document