Predicting need for pacemaker implantation early and late after transcatheter aortic valve implantation

Author(s):  
Anthony J. Mazzella ◽  
Mason Sanders ◽  
Hannan Yang ◽  
Quefeng Li ◽  
John P. Vavalle ◽  
...  
Author(s):  
Helge Möllmann ◽  
David M. Holzhey ◽  
Michael Hilker ◽  
Stefan Toggweiler ◽  
Ulrich Schäfer ◽  
...  

Abstract Background Transcatheter aortic valve implantation (TAVI) has become standard treatment for elderly patients with symptomatic severe aortic valve stenosis. The ACURATE neo AS study evaluates 30-day and 1-year clinical and hemodynamic outcomes in patients treated with the ACURATE neo2 valve. Methods The primary endpoint of this single-arm multicenter study is 30-day all-cause mortality. Other key endpoints include device performance, echocardiographic measures assessed by an independent core laboratory, and VARC-2 clinical efficacy and safety endpoints through 12 months. Results The study enrolled 120 patients (mean age 82.1 ± 4.0 years; 67.5% female, mean baseline STS score 4.8 ± 3.8%). The VARC-2 composite safety endpoint at 30 days occurred in 13.3% of patients. All-cause mortality was 3.3% at 30 days and 11.9% at 1 year. The 30-day stroke rate was 2.5% (disabling stroke 1.7%); there were no new strokes between 30 days and 12 months. The rate of permanent pacemaker implantation was 15.0% (18/120) at 30 days and 17.8% (21/120) at 1 year. No patients required re-intervention for valve-related dysfunction and there were no cases of valve thrombosis or endocarditis. Patients demonstrated significant improvement in mean aortic valve gradient (baseline 38.9 ± 13.1 mmHg, 1 year 7.8 ± 3.5 mmHg; P < 0.001 in a paired analysis). In the overall population, paravalvular leak was evaluated at 1 year as none/trace in 60.5%, mild in 37.0%, and moderate in 2.5%; no patients had severe PVL. Conclusions One-year outcomes from the ACURATE neo AS study support the safety and performance of TAVI with the ACURATE neo2 valve. Graphic Abstract


2021 ◽  
Author(s):  
James Carey ◽  
Anthony Buckley ◽  
Stephen O'Connor ◽  
Mark Hensey

Transcatheter aortic valve implantation and implantation of other transcatheter heart valves, generally requires insertion of a temporary venous pacemaker. Implantation of a temporary venous pacemaker adds complexity, time and risk to the procedure. Guidewire modification to allow pacing is increasingly popular, however it requires technical expertise and provides unipolar pacing resulting in high thresholds and potential capture loss. The Wattson temporary pacing guidewire is a novel device which offers guidewire support for valve delivery and concomitant bipolar pacing. It may offer a safe and effective solution to guidewire pacing for transcatheter aortic valve implantation and other transcatheter heart valve implantations. Herein, we review the literature surrounding left ventricular guidewire pacing along with the features and clinical data of the Wattson wire.


Author(s):  
Adam Penkalla ◽  
Joerg Kempfert ◽  
Axel Unbehaun ◽  
Semih Buz ◽  
Thorsten Drews ◽  
...  

Objective In this report, we assess the outcome of transcatheter aortic valve implantation (TAVI) in nonagenarians at our institution during a 6-year period. Methods Between April 2008 and July 2014, 40 patients with a mean ± SD age of 91.8 ± 2.3 years (range, 90–98 years) underwent TAVI. Thirty-three patients (82.5%) received transapical TAVI, and seven patients (17.5%) received transfemoral TAVI. Baseline characteristics were as follows: mean ± SD EuroSCORE II, 23.9 ± 14.21; mean ± SD Society of Thoracic Surgeons mortality score, 24.2 ± 11.4; mean ± SD SYNTAX score, 7.6 ± 9.3; mean ± SD NYHA class, 3.5 ± 0.5; mean ± SD transvalvular gradient, 46.8 ± 17.8 mm Hg; mean ± SD aortic valve area, 0.7 ± 0.2 cm2. Results Intraoperative mortality was 2.5% and 30-day all-cause mortality was 10%. The actuarial survival rates at 1 and 5 years were 58.6% and 30.4%, respectively. Seven patients (17.5%) underwent simultaneous elective TAVI and percutaneous coronary intervention. Three patients (7.5%) were operated on with the use of cardiopulmonary bypass. No conversion to open surgery occurred. In transesophageal echocardiography assessment, no moderate or severe prosthetic aortic valve regurgitation was observed. Four patients (10%) had postoperative acute renal failure stage 3 and needed new dialysis (P = 0.125). Three patients (7.5%) had a disabling stroke. Periprocedural myocardial infarction occurred in one patient (2.5%). Seven patients (17.5%) needed postoperative pacemaker implantation. Male sex and renal insufficiency were found to be predictors of mortality in univariable analysis. Conclusions Transcatheter aortic valve implantation can be performed in nonagenarians despite very high preoperative risk scores and substantial multimorbidity, with acceptable outcomes.


Author(s):  
Shahram Lotfi ◽  
Guido Dohmen ◽  
Andreas Götzenich ◽  
Marcus Haushofer ◽  
Jan Wilhelm Spillner ◽  
...  

Objective Transcatheter aortic valve implantation (TAVI) has become a therapeutic option for high-risk or nonoperable patients with severe symptomatic aortic valve stenosis. The best known and most frequently implanted prostheses are the CoreValve and SAPIEN prostheses. We report our experiences and analyze the results of our TAVI program. Methods A total of 357 patients underwent transfemoral (TF) and transapical (TA) TAVI in our center between January 2008 and October 2012. The procedure was performed in 190 patients with CoreValve, in 155 patients with SAPIEN, and in 12 patients with ACURATE TA prostheses. Transfemoral access was used in 190 patients. In 167 patients, TA access was used. The mean age was 80.2 ± 6.4 years. All patients were nonoperable or had a high risk for a conventional aortic valve replacement. The mean logistic EuroSCORE I was 25.92 ± 14.51%. The TF/CoreValve (190 patients) and TA/SAPIEN (155 patients) groups showed significant difference in the patients’ mean age (81.7 ± 6.3 years vs. 79.5 ± 6.6 years, P = 0.002) and in mean logistic EuroSCORE I (22.16 ± 13.05% vs. 31.04 ± 16.40, P < 0.001). Results The overall 30-day mortality (357 patients) was 9.80% (TF, 8.42%; TA, 11.37%); overall 1-year mortality (275 patients), 21.45% (TF, 23.74%; TA, 19.12%); overall 2-year mortality (199 patients), 29.15% (TF, 35.96%; TA, 23.64%); overall 3-year mortality (133 patients), 37.59% (TF, 43.86%; TA, 32.89%); and overall 4-year mortality (38 patients), 39.47% (TF, 45%; TA, 33.33%). The rate of pacemaker implantation after TAVI was significantly higher in the CoreValve group than in the SAPIEN group: 44.74% (85/190 patients) versus 6.45% (10/155 patients), P < 0.001. Stroke rate was higher in the TF-CoreValve group than in the TA-SAPIEN group: 4.21% versus 0.64%, P = 0.045. Conclusions Outcomes after TAVI were, in our population of nonoperable and high-risk patients, encouraging. The differences in midterm outcomes between the TF-CoreValve TAVI and the TA-SAPIEN TAVI were not significant.


Sign in / Sign up

Export Citation Format

Share Document