Voltage Control of Static Var Compensator for a Remote System Interconnected by Long-Distance AC Cables

2013 ◽  
Vol 186 (3) ◽  
pp. 19-30
Author(s):  
Yuji Tamura ◽  
Shinji Takasaki ◽  
Yasuyuki Miyazaki ◽  
Hideo Takeda ◽  
Shoichi Irokawa ◽  
...  
2011 ◽  
Vol 131 (11) ◽  
pp. 896-904
Author(s):  
Yuji Tamura ◽  
Shinji Takasaki ◽  
Yasuyuki Miyazaki ◽  
Hideo Takeda ◽  
Shoichi Irokawa ◽  
...  

Energies ◽  
2019 ◽  
Vol 12 (4) ◽  
pp. 742 ◽  
Author(s):  
Gen Li ◽  
Wei Liu ◽  
Tibin Joseph ◽  
Jun Liang ◽  
Ting An ◽  
...  

With the increasing demand of transmitting bulk-power over long-distance, the ultra high-voltage direct-current (UHVDC) transmission systems become an attractive option. Nowadays, not only the line commutated converter (LCC) based systems, but also the modular multilevel converter (MMC) based systems have reached UHVDC levels. The converter stations of UHVDC systems normally utilize two series-connected valve-groups to reduce the difficulties of device manufacturing and transportation. This high-voltage and low-voltage valve-group configuration allows the UHVDC systems to achieve a full-voltage to half-voltage operation which increases the flexibility of the systems. However, the existing research only focuses on the full-voltage to half-voltage control of LCC-UHVDC systems. The control strategies for hybrid LCC/MMC UHVDC systems are underresearched. Moreover, the approaches to reduce the load-shedding caused by the full-voltage to half-voltage control for both LCC and hybrid LCC/MMC based UHVDC systems have not been investigated. In this paper, full-voltage to half-voltage control strategies for both LCC and hybrid LCC/MMC based UHVDC systems have been proposed. Moreover, to avoid load-shedding caused by the half-voltage operation, a power rescheduling method that re-sets the power references of the half-voltage operating and full-voltage operating poles has been proposed. The proposed full-voltage to half-voltage control strategies and power rescheduling method can achieve a stable and fast control process with a minimum power loss. The proposed methods have been verified through the time-domain simulations conducted in PSCAD/EMTDC.


Author(s):  
Nor Adni Binti Mat Le ◽  
W Mohd Nazmi bin W Musa ◽  
Nurlida Binti Ismail ◽  
Nurul Huda binti Ishak ◽  
Nur Ashida binti Salim

One of the major causes of voltage instability in power system is the reactive power limit. Therefore, this paper aims to analyze the effect of Static Var Compensator (SVC) on voltage stability of a power system. There are many ways to control the voltage, but in this paper only focus on the SVC and IEEE-9 buses. The SVC circuit and IEEE-9 buses were designed and modelled in Power World. The Newton Raphson method was applied to compute the load flow solution. Then, the reactive power (Q) was injected to SVC and the effect of SVC on IEEE 9-buses were studied. The analysis of voltage control was considered the conditions of fault occurred at the bus. The simulation results obtained in Power World demonstrate that the improvement voltage in the IEEE 9-buses when the Q was injected into SVC circuit. Besides, the QV curve was plotted to show the sensitivity and variation bus voltages with respect to the Q injection.


2016 ◽  
Vol 839 ◽  
pp. 54-58 ◽  
Author(s):  
Piyadanai Pachanapan ◽  
Phudit Inthai

A micro static var compensator (µSVC) is introduced in this work to prevent the over-voltage problems in radial distribution networks with high number of rooftop photovoltaic (PV) connections. The µSVC is aimed to use in the PV system that has the fixed-power factor inverter, which cannot provide the active voltage controllability. The µSVC is a small shunt compensator installed parallel with the PV system and providing the automatic reactive power support to deal with the dynamic voltage variations at the point of common coupling. Two reactive power control methods, Q(P) and Q(V), can be employed into each µSVC depending on the location of PV systems. Moreover, the coordinated reactive power control among µSVCs, without communication system requirement, is presented for enhancing the Volt-Var controllability to the group of PV systems located in the same feeder. The dynamic voltage control performances are examined on simulation in DIgSILENT PowerFactory software. The results showed that the proposed control method can mitigate the rise of voltage level sufficiently.


Sign in / Sign up

Export Citation Format

Share Document