Evaluation of the seismic performance of a code-conforming reinforced-concrete frame building—from seismic hazard to collapse safety and economic losses

2007 ◽  
Vol 36 (13) ◽  
pp. 1973-1997 ◽  
Author(s):  
Christine A. Goulet ◽  
Curt B. Haselton ◽  
Judith Mitrani-Reiser ◽  
James L. Beck ◽  
Gregory G. Deierlein ◽  
...  
2018 ◽  
Vol 195 ◽  
pp. 02017
Author(s):  
Isyana Ratna Hapsari ◽  
Senot Sangadji ◽  
Stefanus Adi Kristiawan

Masonry infilled reinforced concrete frames are a structural system commonly used for low-to-mid-rise buildings. Generally, this type of structure is modelled as an open frame neglecting the strength and stiffness contribution of the masonry infilled panel. In order to describe realistic behaviour under lateral loading, this paper evaluates the seismic performance of the building by modelling the contribution of masonry as a compression strut acting diagonally in the panel. The non-linear static procedure is employed by subjecting the building to pushover loads. The performance of the building is then analysed based on the obtained capacity curve. Seismic performance is assessed in terms of building fragility which is the conditional probability of exceeding certain damage state for a given ground shaking intensity. Fragility functions eventually are expressed as series of log-normal curves of both the open and masonry infilled reinforced concrete frame. Based on this study, the infilled frame can resist a maximum load of 20.3x103 kN, while the open frame is only able to withstand a maximum load of 15.2x103 kN. From the fragility curve, it can be concluded that the probability of the infilled frame to reach a certain damage state is lower than that of the open frame.


2011 ◽  
Vol 255-260 ◽  
pp. 2421-2425
Author(s):  
Qiu Wei Wang ◽  
Qing Xuan Shi ◽  
Liu Jiu Tang

The randomness and uncertainty of seismic demand and structural capacity are considered in demand-capacity factor method (DCFM) which could give confidence level of different performance objectives. Evaluation steps of investigating seismic performance of steel reinforced concrete structures with DCFM are put forward, and factors in calculation formula are modified based on stress characteristics of SRC structures. A regular steel reinforced concrete frame structure is analyzed and the reliability level satisfying four seismic fortification targets are calculated. The evaluation results of static and dynamic nonlinear analysis are compared which indicates that the SRC frame has better seismic performance and incremental dynamic analysis could reflect more dynamic characteristics of structures than pushover method.


1999 ◽  
Vol 26 (5) ◽  
pp. 606-617 ◽  
Author(s):  
A C Heidebrecht ◽  
N Naumoski

This paper describes an investigation into the seismic performance of a six-storey ductile moment-resisting frame structure located in Vancouver and designed and detailed in accordance with the seismic provisions of the National Building Code of Canada (1995). Both pushover and dynamic analyses are conducted using an inelastic model of the structure as designed and detailed. The structural performance of a number of design variations is evaluated using interstorey drift and member curvature ductility response as performance measures. All frames studied are expected to perform at an operational level when subjected to design level seismic excitations and to meet life safe performance criteria at excitations of twice the design level.Key words: seismic, building, frames, ductile, design, performance, reinforced concrete, code.


2020 ◽  
Vol 10 (20) ◽  
pp. 7061 ◽  
Author(s):  
Kyong Min Ro ◽  
Min Sook Kim ◽  
Young Hak Lee

Buildings constructed with non-seismic details are at risk of damage and collapse when an earthquake occurs due to a lack of strength, stiffness, and ductility. For reinforced concrete (RC) moment-resisting frames, seismic retrofitting methods that can enhance strength or ductility should be applied. However, such strategies have many disadvantages related to constructability, serviceability, securing integrity, and cost. In this paper, a welded concrete-filled steel tube (WCFST) system was examined in order to resolve the problems of the existing seismic retrofitting methods for RC moment-resisting frames. To evaluate the seismic performance of the proposed system, two specimens, one with non-seismic details and another reinforced with a WCFST seismic system, were manufactured for the cyclic loading tests. As a result of the experiments, the specimen retrofitted with the WCFST system showed maximum load, effective stiffness, and energy dissipation capacity values approximately 3, 2, and 2.5 times greater, respectively, than those obtained from the existing reinforced concrete frame specimen. The experimental results indicate that the proposed WCFST system is expected to be effective at improving the seismic performance by enhancing both the strength of the existing reinforced concrete frame structures and the dissipation of the seismic energy.


Sign in / Sign up

Export Citation Format

Share Document