Seismic performance of ductile medium height reinforced concrete frame buildings designed in accordance with the provisions of the 1995 National Building Code of Canada

1999 ◽  
Vol 26 (5) ◽  
pp. 606-617 ◽  
Author(s):  
A C Heidebrecht ◽  
N Naumoski

This paper describes an investigation into the seismic performance of a six-storey ductile moment-resisting frame structure located in Vancouver and designed and detailed in accordance with the seismic provisions of the National Building Code of Canada (1995). Both pushover and dynamic analyses are conducted using an inelastic model of the structure as designed and detailed. The structural performance of a number of design variations is evaluated using interstorey drift and member curvature ductility response as performance measures. All frames studied are expected to perform at an operational level when subjected to design level seismic excitations and to meet life safe performance criteria at excitations of twice the design level.Key words: seismic, building, frames, ductile, design, performance, reinforced concrete, code.

2011 ◽  
Vol 255-260 ◽  
pp. 2421-2425
Author(s):  
Qiu Wei Wang ◽  
Qing Xuan Shi ◽  
Liu Jiu Tang

The randomness and uncertainty of seismic demand and structural capacity are considered in demand-capacity factor method (DCFM) which could give confidence level of different performance objectives. Evaluation steps of investigating seismic performance of steel reinforced concrete structures with DCFM are put forward, and factors in calculation formula are modified based on stress characteristics of SRC structures. A regular steel reinforced concrete frame structure is analyzed and the reliability level satisfying four seismic fortification targets are calculated. The evaluation results of static and dynamic nonlinear analysis are compared which indicates that the SRC frame has better seismic performance and incremental dynamic analysis could reflect more dynamic characteristics of structures than pushover method.


2020 ◽  
Vol 10 (20) ◽  
pp. 7061 ◽  
Author(s):  
Kyong Min Ro ◽  
Min Sook Kim ◽  
Young Hak Lee

Buildings constructed with non-seismic details are at risk of damage and collapse when an earthquake occurs due to a lack of strength, stiffness, and ductility. For reinforced concrete (RC) moment-resisting frames, seismic retrofitting methods that can enhance strength or ductility should be applied. However, such strategies have many disadvantages related to constructability, serviceability, securing integrity, and cost. In this paper, a welded concrete-filled steel tube (WCFST) system was examined in order to resolve the problems of the existing seismic retrofitting methods for RC moment-resisting frames. To evaluate the seismic performance of the proposed system, two specimens, one with non-seismic details and another reinforced with a WCFST seismic system, were manufactured for the cyclic loading tests. As a result of the experiments, the specimen retrofitted with the WCFST system showed maximum load, effective stiffness, and energy dissipation capacity values approximately 3, 2, and 2.5 times greater, respectively, than those obtained from the existing reinforced concrete frame specimen. The experimental results indicate that the proposed WCFST system is expected to be effective at improving the seismic performance by enhancing both the strength of the existing reinforced concrete frame structures and the dissipation of the seismic energy.


2019 ◽  
Vol 2019 ◽  
pp. 1-17 ◽  
Author(s):  
Syed Azmat Ali Shah ◽  
Junaid Shah Khan ◽  
Syed Muhammad Ali ◽  
Khan Shahzada ◽  
Waqar Ahmad ◽  
...  

Half-scaled reinforced concrete frame of two storeys and two bays with unreinforced masonry (URM) infill walls was subjected to base excitation on a shake table for seismic performance evaluation. Considering the high seismic hazard Zone IV of Pakistan, reinforcement detailing in the RC frame is provided according to special moment resisting frames (SMFRs) requirement of Building Code of Pakistan Seismic-Provisions (BCP SP-2007). The reinforced concrete frame was infilled with in-plane solid masonry walls in its interior frame, in-plane masonry walls with door and window openings in the exterior frame, out-of-plane solid masonry wall, and masonry wall with door and window openings in its interior frame. For seismic capacity qualification test, the structure was subjected to three runs of unidirectional base excitation with increasing intensity. For system identification, ambient-free vibration tests were performed at different stages of experiment. Seismic performance of brick masonry infill walls in reinforced concrete frame structures was evaluated. During the shake table test, performance of URM infill walls was satisfactory until design ground acceleration was 0.40g with a global drift of 0.23%. The test was continued till 1.24g of base acceleration. This paper presents key findings from the shake table tests, including the qualitative damage observations and quantitative force-displacement, and hysteretic response of the test specimen at different levels of excitation. Experimental results of this test will serve as a benchmark for validation of numerical and analytical models.


2012 ◽  
Vol 594-597 ◽  
pp. 1680-1683
Author(s):  
Hai Tao Wan ◽  
Yu Qing Yuan

Reinforced concrete ( RC) frame structure is one type of building structure which is widely used in China. Damage of some reinforced concrete frame structures under the earthquake is caused by the damage of RC beams, So RC beams are an essential seismic members. The paper introduces the design of RC beam specimen, mechanical properties of materials, production of RC beam specimen, test method, loading device, loading system, the contents of measurement and data acquisition in detail. From the above analysis, it is obvious that the test is the most effective means of studying the seismic performance of beam.


Author(s):  
Taochun Yang ◽  
Yanjun Li ◽  
Xiaohui Zhai

In order to study the degradation law and seismic performance of reinforced concrete frame structure with the extension of service time under normal service environment, the multi-scale modeling of corroded reinforced concrete frame is carried out by using the general finite element analysis software ABAQUS. The correctness of the multi-scale modeling method is verified by the experimental data of corroded reinforced concrete members and single frame. The pushover analysis and elastic-plastic time history analysis of a four story reinforced concrete frame structure are carried out by using a multi-scale model. Then the seismic response and damage of RC frame structures with different service time are compared. The experimental results show that the established seismic performance model of reinforced concrete frame structure is more practical in practical application and can meet the research requirements.


Sign in / Sign up

Export Citation Format

Share Document