A combining signal amplification of atom transfer radical polymerization and redox polymerization for visual biomolecules detection

2014 ◽  
Vol 52 (19) ◽  
pp. 2791-2799 ◽  
Author(s):  
Dequan Zhuang ◽  
Heyun Shen ◽  
Guodong Liu ◽  
Changyuan Yu ◽  
Jing Yang
2018 ◽  
Vol 18 (3) ◽  
pp. 537 ◽  
Author(s):  
Melahat Göktaş ◽  
Guodong Deng

Poly(methyl methacrylate)-b-poly(N-isopropylacrylamide) [PMMA-b-PNIPAM] block copolymers were obtained by a combination of redox polymerization and atom transfer radical polymerization (ATRP) methods in two steps. For this purpose, PMMA macroinitator (ATRP-macroinitiator) was synthesized by redox polymerization of methyl methacrylate and 3-bromo-1-propanol using Ce(NH4)2(NO3)6 as a catalyst. The synthesis of PMMA-b-PNIPAM block copolymers was carried out by means of ATRP of ATRP-macroinitiator and NIPAM at 60 °C. The block copolymers were obtained in high yield and high molecular weight. The characterization of products was accomplished by using multi instruments and methods such as nuclear magnetic resonance spectroscopy, Fourier transform infrared spectroscopy, gel permeation chromatography, and thermogravimetric analysis.


2021 ◽  
Vol 188 (4) ◽  
Author(s):  
Lihe Jian ◽  
Xiaolan Wang ◽  
Lulu Hao ◽  
Yanju Liu ◽  
Huaixia Yang ◽  
...  

AbstractThe cytokeratin fragment antigen 21-1 (CYFRA 21-1) protein is a critical tumor biomarker tightly related to non-small cell lung cancer (NSCLC). Herein, we prepared an effective electrochemiluminescence (ECL) immunosensor for CYFRA 21-1 detection using electrochemically mediated atom transfer radical polymerization (eATRP). The CYFRA 21-1 antigen was fixed on the electrode surface by constructing a sandwich type antibody-antigen-antibody immune system. The sensitivity of ECL was improved by using the eATRP reaction. In this method, eATRP was applied to CYFRA 21-1 detection antibody with N-acryloyloxysuccinimide as functional monomer. This is the first time that ECL and eATRP signal amplification technology had been combined. Under the optimized testing conditions, the immunosensor showed a good linear relation in the range from 1 fg mL−1 to 1 μg mL−1 at a limit of detection of 0.8 fg mL−1 (equivalent to ~ 134 molecules in a 10 μL sample). The ECL immunosensing system based on eATRP signal amplification technology provided a new way for rapid diagnosis of lung cancer by detecting CYFRA 21-1. Graphical abstract


2010 ◽  
Vol 43 (9) ◽  
pp. 4133-4139 ◽  
Author(s):  
Jun Kamada ◽  
Kaloian Koynov ◽  
Cathrin Corten ◽  
Azhar Juhari ◽  
Jeong Ae Yoon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document