The stretched quadrupole ion trap: Implications for the Mathieuau andqu parameters and experimental mapping of the stability diagram

1992 ◽  
Vol 6 (12) ◽  
pp. 760-764 ◽  
Author(s):  
Jodie V. Johnson ◽  
Randall E. Peddeer ◽  
Richard A. Yost ◽  
R. E. March
2005 ◽  
Vol 11 (1) ◽  
pp. 15-21 ◽  
Author(s):  
Kwenga F. Sichilongo ◽  
Bert C. Lynn

Real-time experiments involving fragmentation of the precursor molecular ion of n-butylbenzene ( m/z 134) to produce product ions C7H+7 ( m/z 91) and C7H+8 ( m/z 92), were used to observe the motion of ions in a commercial quadrupole ion trap. Initially, ghost resonance peaks were observed for excitation of the precursor ion at qz values of 0.4 and 0.5 on the qz axis of the stability diagram. Further experiments involving the generation of two-dimensional contour plots confirmed that these ghost peaks, which were in agreement with mathematical equations describing the motion of ions in a quadrupole field, arose due to waveboard artifacts. Two-dimensional contour surface plots showed non-linear secular frequency canyons from a qz value of 0.5 to higher values corresponding with higher drive radio frequency (rf) voltages on the stability diagram. This observation confirmed that ions are subjected to non-linear effects in this mass scan range. The octapole and hexapole field lines were observed at qz values of 0.65 and 0.78, respectively.


2017 ◽  
Vol 23 (5) ◽  
pp. 254-271 ◽  
Author(s):  
Sarkhosh S Chaharborj ◽  
Abbas Moameni

In this article, fractional calculus has been applied to study the motion of ions in a three-dimensional radio frequency quadrupole ion trap; we have called this arrangement a fractional quadrupole ion trap. The main purpose of the article is to show that by controlling the fractional parameter of a trapped ion, one can gain a more efficient mass separation. In what follows, we will see that with decreasing the fractional parameter, we can achieve a smaller first stability region. Note that a small stability diagram will result in a good and acceptable mass separation. Various methods can be proposed to obtain a desired ion acceleration with a sufficient accuracy for good mass separation, which is similar to the one obtained by a fractional ion trap. Some of these methods are using the effects of a damping force, a magnetic field or both on the confinement of particles in the quadrupole ion trap. The first stability regions are plotted for all of the aforementioned methods, and simulation results are provided to compare them with those for the fractional case.


2013 ◽  
Vol 336 ◽  
pp. 47-52 ◽  
Author(s):  
Steffi Bandelow ◽  
Gerrit Marx ◽  
Lutz Schweikhard

2019 ◽  
Vol 55 (94) ◽  
pp. 14139-14142 ◽  
Author(s):  
Bernardo Monteiro ◽  
Nuno A. G. Bandeira ◽  
Célia Lourenço ◽  
Ana F. Lucena ◽  
José M. Carretas ◽  
...  

The diverse gas-phase reactivity of [LnO2(NO3)2]− complexes with water (Ln = Ce, Pr, Nd), examined in a quadrupole ion trap and complemented by ab initio computations, illuminates the chemical stability of Pr in the unusual +5 oxidation state.


2021 ◽  
Vol 217 (1) ◽  
Author(s):  
J. Simcic ◽  
D. Nikolić ◽  
A. Belousov ◽  
D. Atkinson ◽  
C. Lee ◽  
...  

AbstractTo date, a variety of different types of mass spectrometers have been utilized on missions to study the composition of atmospheres of solar system bodies, including Venus, Mars, Jupiter, Titan, the moon, and several comets. With the increasing interest in future small probe missions, mass spectrometers need to become even more versatile, lightweight, compact, and sensitive.For in situ exploration of ice giant atmospheres, the highest priority composition measurements are helium and the other noble gases, noble gas isotopes, including 3He/4He, and other key isotopes like D/H. Other important but lower priority composition measurements include abundances of volatiles C, N, S, and P; isotopes 13C/12C, 15N/14N, 18O/17O/16O; and disequilibrium species PH3, CO, AsH3, GeH4, and SiH4. Required measurement accuracies are largely defined by the accuracies achieved by the Galileo (Jupiter) probe Neutral Mass Spectrometer and Helium Abundance Detectors, and current measurement accuracies of solar abundances.An inherent challenge of planetary entry probe mass spectrometers is the introduction of material to be sampled (gas, solid, or liquid) into the instrument interior, which operates at a vacuum level. Atmospheric entry probe mass spectrometers typically require a specially designed sample inlet system, which ideally provides highly choked, nearly constant mass-flow intake over a large range of ambient pressures. An ice giant descent probe would have to operate for 1-2 hours over a range of atmospheric pressures, possibly covering 2 or more orders of magnitude, from the tropopause near 100 mbar to at least 10 bars, in an atmospheric layer of depth beneath the tropopause of about 120 km at Neptune and about 150 km at Uranus.The Jet Propulsion Laboratory’s Quadrupole Ion Trap Mass Spectrometer (QITMS) is being developed to achieve all of these requirements. A compact, wireless instrument with a mass of only 7.5 kg, and a volume of 7 liters (7U), the JPL QITMS is currently the smallest flight mass spectrometer available for possible use on planetary descent probes as well as small bodies, including comet landers and surface sample return missions. The QITMS is capable of making measurements of all required constituents in the mass range of 1–600 atomic mass units (u) at a typical speed of 50 mass spectra per second, with a sensitivity of up to $10^{13}$ 10 13  counts/mbar/sec and mass resolution of $m/\Delta m=18000$ m / Δ m = 18000 at m/q = 40. (Throughout this paper we use the unit of m/q = u/e for the mass-to-charge ratio, where atomic mass unit and elementary charge are $1~\text{u} = 1.66\times 10^{-27}~\text{kg}$ 1 u = 1.66 × 10 − 27 kg and $1\text{e} = 1.6\times 10^{-19}$ 1 e = 1.6 × 10 − 19 C, respectively.) The QITMS features a novel MEMS-based inlet system driven by a piezoelectric actuator that continuously regulates gas flow at inlet pressures of up to 100 bar.In this paper, we present an overview of the QITMS capabilities, including instrument design and characteristics of the inlet system, as well as the most recent results from laboratory measurements in different modes of operation, especially suitable for ice giant atmospheres exploration.


2000 ◽  
Vol 194 (2-3) ◽  
pp. 225-234 ◽  
Author(s):  
Carsten Weil ◽  
J.Mitchell Wells ◽  
H Wollnik ◽  
R.Graham Cooks