Nuclear Electric’s Contributions to the CONTESSE Testing Framework and its Early Application

Author(s):  
G. Hughes ◽  
D. Pavey ◽  
J. H. R. May ◽  
P. A. V. Hall ◽  
H. Zhu ◽  
...  
2015 ◽  
Vol 156 (15) ◽  
pp. 609-613
Author(s):  
Miklós Somlói ◽  
Emil Toldy-Schedel ◽  
Zoltán Nényei ◽  
Róbert Böszörményi ◽  
János Tomcsányi

Introduction: Extension of electrocardiographic monitoring via loop recorder implantation may increase the diagnostic yield of syncope work-up. Aim: In this retrospective observational study, the authors wanted to evaluate the diagnostic performance of implantable loop recorder in the everyday clinical practice. Method: The authors analyzed the electronically stored data of all patients who underwent loop recorder implantation between 2005 and 2014 in their cardiology department because of recurrent syncope of undetermined origin. Results: There were 52 loop recorder implantations within the study period. During the 167 (±136) days of monitoring, 36 (69.2%) diagnostic events occurred. In two-thirds of events, (46.2% of all monitored patients) a specific arrhythmia diagnosis was reached, allowing definitive treatment in these cases. In this selected population, there was no correlation between age, presence of known high-risk predictors, or accompanying trauma, and the mechanism of syncope. Conclusions: The high diagnostic rate of implantable loop recorder in the everyday clinical practice is in accordance with the findings in prospective clinical studies. This observation supports the early application of loop recorder in the diagnostic algorithm of syncope. Orv. Hetil., 2015, 156(15), 609–613.


2021 ◽  
Vol 108 (Supplement_3) ◽  
Author(s):  
M Osorio Capitan ◽  
S Rose ◽  
I Novo Sukia ◽  
B Herrero de la Parte ◽  
I Ruiz Montesinos ◽  
...  

Abstract INTRODUCTION Chemotherapy hinders liver function and probably its regenerating capacity, forcing to delay it after surgery. Our objective has been to verify this effect in an experimental model and to see if a hepatotrophic agent can prevent it. MATERIAL AND METHODS Four groups of 6 WAG/RijHsd rats (males, 3-4 months) were submitted to ligation of the portal branch to the left lateral and left paramedian lobes. They were sacrificed 36 h later to quantify the percentage of liver corresponding to the ligated lobes (weight), the number of hepatocyte’s nuclei (nº/100 µm2) and their mean size (µm2). One group received no treatment (control); another folic acid (2.5 mg/kg ip, during surgery); other 5-Fluorouracil (5-FU 50 mg/kg ip 48 h before); and the fourth received folic&5-FU. RESULTS The animals treated with folic acid showed a greater number of hepatocyte’s nuclei (24.4 ± 2.77 vs 15.2 ± 1.51) and their mean size was also greater (121 ± 2.34 vs 111 ± 1.8). However, the reduction in weight of the ligated parenchyma was less than in control group (33.4 ± 1.08 vs 29.5 ± 1.08). 5-FU did not modify the number of nuclei (15.6 ± 18.4), although they were smaller in size (104 ± 1.7). The addition of folic acid to 5-FU increased the number of nuclei (21.7 ± 2.8) and normalized their size (111 ± 3.2). CONCLUSIONS 5-FU exerts a depressant effect on livers regeneration, and folic acid overcomes it. Thus, folic acid could allow early application of chemotherapy without affecting liver regeneration.


2021 ◽  
Author(s):  
Nihan Şık ◽  
Hüseyin Bahadır Şenol ◽  
Aykut Çağlar ◽  
Durgül Yılmaz ◽  
Murat Duman

2021 ◽  
Vol 1 ◽  
pp. 3199-3208
Author(s):  
Emanuel Balzan ◽  
Pierre Vella ◽  
Philip Farrugia ◽  
Edward Abela ◽  
Glenn Cassar ◽  
...  

AbstractResearch funded projects are often concerned with the development of proof-of-concept products. Consequently, activities related to verification and validation testing (VVT) are often not considered in depth, even though various design iterations are carried out to refine an idea. Furthermore, the introduction of additive manufacturing (AM) has facilitated, in particular, the development of bespoke medical products. End bespoke products, which will be used by relevant stakeholders (e.g. patients and clinicians) are fabricated with the same manufacturing technologies used during prototyping. As a result, the detailed design stage of products fabricated by AM is much shorter. Therefore, to improve the market-readiness of bespoke medical devices, testing must be integrated within the development from an early stage, allowing better planning of resources. To address these issues, in this paper, a comprehensive VVT framework is proposed for research projects, which lack a VVT infrastructure. The framework builds up on previous studies and methods utilised in industry to enable project key experts to capture risks as early as the concept design stage.


Sign in / Sign up

Export Citation Format

Share Document