Monte Carlo Determinations of Optimal Photon Energies for XRF Analysis of Iodine in Vivo

1981 ◽  
pp. 371-376 ◽  
Author(s):  
T. Grönberg ◽  
S. Mattsson
Keyword(s):  
1980 ◽  
Vol 24 ◽  
pp. 371-376
Author(s):  
T. Grönberg ◽  
S. Mattsson

After the pioneering work of HOFFER et al. on fluorescent scanning of natural iodine in the thyroid, several authors have suggested the use of X-ray fluorescence analysis to follow in vivo the distribution and elimination of stable tracers injected prior to the investigation. The normal method of performing such studies is to inject iodine containing contrast media and then follow the variation in iodine concentration by in vivo measurements over the organ or tissue of interest.A theoretical treatment of the application of X-ray fluorescence in in vivo studies has been made by TINNEY by means of analytical calculations.


2019 ◽  
Vol 59 ◽  
pp. 30-36 ◽  
Author(s):  
Joel Poder ◽  
Dean Cutajar ◽  
Susanna Guatelli ◽  
Marco Petasecca ◽  
Andrew Howie ◽  
...  

2009 ◽  
Vol 96 (5) ◽  
pp. 558-567 ◽  
Author(s):  
Stephanie Lamart ◽  
Eric Blanchardon ◽  
Andrey Molokanov ◽  
Gary H. Kramer ◽  
David Broggio ◽  
...  

1998 ◽  
Vol 49 (5-6) ◽  
pp. 673-676 ◽  
Author(s):  
R.P. Hugtenburg ◽  
J.R. Turner ◽  
D.M. Mannering ◽  
B.A. Robinson

1990 ◽  
pp. 297-301 ◽  
Author(s):  
U. Nilsson ◽  
L. Ahlgren ◽  
J-O. Christoffersson ◽  
S. Mattsson
Keyword(s):  

2021 ◽  
Author(s):  
Eric Da Silva

A hydroxyaptite [HAp; Ca5(PO4)3OH] phantom material was developed with the goal of improving the calibration protocol of the 125I-induced in vivo X-ray fluorescence (IVXRF) system of bone strontium quantification with further application to other IVXRF bone metal quantification systems, particulary those associated with bone lead quantification. It was found that calcium can be prepared pure of inherent contamination from strontium (and other elements) through a hydroxide precipitation producing pure Ca(OH)2, thereby, allowing for the production of a blank phantom which has not been available previously. The pure Ca(OH)2 can then be used for the preparation of pure CaHPO4 ⋅ 2H2O. A solid state pure HAp phantom can then be prepared by reaction of Ca(OH)2 and CaHPO4 ⋅ 2H2O mixed as to produce a Ca/P mole ratio of 1.67, that in HAp and the mineral phase of bone, in the presence of a setting solution prepared as to raise the total phosphate concentration of the solution by increasing the solubility CaHPO4 ⋅ 2H2O and thereby precipitating HAp. The procedure can only be used to prepare phantoms in which doping with the analyte does not disturb the Ca/P ratio substantially. In cases in which phantoms are to be prepared with high concentrations of strontium, the cement mixture can be modified as to introduce strontium in the form of Sr(OH)2 ⋅ 8H2O as to maintain a (Ca + Sr)/P ratio of 1.67. It was found by both X-ray diffraction spectrometry and Raman spectroscopy studies that strontium substitutes for calcium as in bone when preparing phantoms by this route. The necessity for the blank bone phantoms was assessed through the first blank bone phantom measurement and Monte Carlo simulations. It was found that for the 125I-induced IVXRF system of bone strontium quantification, the source, 125I brachytherapy seeds may be contributing coherently and incoherently scattered zirconium X-rays to the measured spectra, thereby requiring the use of the blank bone phantom as a means of improving the overall quantification methodology. Monte Carlo simulations were employed to evaluate any improvement by the introduction of HAp phantoms into the coherent normalization-based calibration procedure. It was found that HAp phantoms remove the need for a coherent conversion factor (CCF) thereby potentially increasing accuracy of the quantification. Further, it was found that in order for soft tissue attenuation corrections to be possible using spectroscopic information alone, HAp along with a suitable soft tissue surrogate material need to be employed. The HAp phantom material was used for the evaluations of portable X-ray analyzer systems for their potential for IVXRF quantification of lead and strontium with a focus on a comparison between tungsten, silver and rhodium target systems. Silver and rhodium target X-ray tube systems were found to be comparable for this quantification.


Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2207
Author(s):  
Anna N. Yaroslavsky ◽  
Amy F. Juliano ◽  
Ather Adnan ◽  
Wayne J. Selting ◽  
Tyler W. Iorizzo ◽  
...  

An in vivo validation study was performed to confirm the accuracy of extraoral photobiomodulation therapy (PBMT) dosimetry determined by modelling. The Monte Carlo technique was utilized to calculate the fluence rate and absorbed power of light delivered through multi-layered tissue. Optical properties used during Monte Carlo simulations were taken from the literature. Morphological data of four study volunteers were acquired using magnetic resonance imaging (MRI) scans. Light emitting diode (LED) coupled to a power meter were utilized to measure transmitted power through each volunteer’s cheek, in vivo. The transmitted power determined by Monte Carlo modelling was compared to the in vivo measurements to determine the accuracy of the simulations. Experimental and simulation results were in good agreement for all four subjects. The difference between the mean values of the measured transmission was within 12% from the respective transmission obtained using Monte Carlo simulations. The results of the study indicate that Monte Carlo modelling is a robust and reliable method for light dosimetry.


Sign in / Sign up

Export Citation Format

Share Document