Thermal Design and Performance Analysis of a Cross Flow Heat Exchanger Using Plain and Almond Dimple Tubes

2019 ◽  
pp. 725-743
Author(s):  
Yogesh Pradeep Bhatt ◽  
Ashutosh Arun Joglekar ◽  
Dattatray B. Hulwan
Author(s):  
Kiran Lankalapalli ◽  
Ahmed ElSawy ◽  
Stephen Idem

A steady state sensible performance analysis of multi-pass cross-flow finned-tube heat exchangers is reported. The investigation considers various flow circuiting, such as counter cross-flow, parallel cross-flow, and cross-flow where the tube-side flow is in parallel. A previously developed matrix approach is used to evaluate the heat exchanger performance in each tube pass. The equations required to model the thermal performance of these configurations are presented, and the thermal performance is compared for each type of flow circuiting. Thereafter a parametric study on cross-flow heat exchanger performance is performed by varying physically significant parameters such as number of transfer units (NTU) and capacity rate ratios, and the graphical results for each type of flow circuiting are presented both for both two-pass and three-pass arrangements. A consistent criterion is proposed for each case, wherein increasing the NTU beyond a certain threshold value does not significantly improve heat exchanger thermal performance.


Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5489
Author(s):  
Karthik Silaipillayarputhur ◽  
Tawfiq Al-Mughanam

All process industries involve the usage of heat exchanger equipment and understanding its performance during the design phase is very essential. The present research work specifies the performance of a pure cross flow heat exchanger in terms of dimensionless factors such as number of transfer units, capacity rate ratio, and heat exchanger effectiveness. Steady state sensible heat transfer was considered in the analysis. The matrix approach that was established in the earlier work was used in the study. The results were depicted in the form of charts, tables, and performance equations. It was observed that indeterminately increasing the number of transfer units past a threshold limit provided very marginal improvement in the performance of a pure cross flow heat exchanger. Likewise, flow pattern in a heat exchanger is usually assumed either as mixed or unmixed. However, due to various operating conditions, partially mixed conditions do exist. This work considers partially mixed conditions in the tube side of the heat exchanger. The correction factor for heat exchanger effectiveness was developed to accommodate partially mixed flow conditions in the pure cross flow heat exchanger.


2018 ◽  
Author(s):  
Bharath P ◽  
Doddamani Hithaish ◽  
Saravanan Venkatesh ◽  
C K Umesh

Sign in / Sign up

Export Citation Format

Share Document