scholarly journals Study the flow direction and number of tubes in cross-flow heat exchanger to improve the heat transfer coefficient.

2021 ◽  
Vol 1076 (1) ◽  
pp. 012075
Author(s):  
Shatha Ali Merdan ◽  
Zena khalefa Kadhim
2018 ◽  
Vol 240 ◽  
pp. 02004 ◽  
Author(s):  
Tomasz Bury ◽  
Małgorzata Hanuszkiewicz Drapała

The work is a part of a thermodynamic analysis of a finned cross-flow heat exchanger of the liquid-gas type. The heat transfer coefficients on the liquid and the gas side and the area of the heat transfer are the main parameters describing such a device. The basic problem in computations of such heat exchangers is determination of the coefficient of the heat transfer from the finned surfaces to the gas. The differences in the heat transfer coefficient local values resulting from the non-uniform flow of mediums through the exchanger complicates the analysis additionally. Six Nusselt number relationships are selected as suitable for the considered heat exchanger, and they are used to calculate the heat transfer coefficient for the air temperature ranging from 10°C to 30°C and for the velocity values ranging from 2 m/s to 20 m/s. In the next step, the gas-side heat transfer coefficient is determined by means of numerical simulations using a numerical model of a repetitive fragment of the heat exchanger under consideration. Finally, the Wilson plot method is also used. The work focuses on an analysis of the in-house HEWES code sensitivity to the method of the heat transfer coefficient determination. The authors believe that the analysis may also be useful for the evaluation of different methods of the heat transfer coefficient computation.


Author(s):  
Farah Abdulzahra Taher ◽  
Zena Khalefa Kadhim

The aim of this study to improve the performance of heat exchanger by using the medium integral fins on the cross flow heat exchanger practically, so, two the heat exchangers from copper were manufactures with eight passes for comparison under different boundary conditions. The water flow rate flow inner the tubes with (2, 3, 4, 5, 6) L/min with inlet temperatures (50, 60, 70) oC, as for the air flow rate were passed outer the tubes by speeds (1, 1.7, 2.3) m/sec. The results show that the medium integral finned tube gives more improvement the heat transfer than the smooth tube about 203.97% and 205.1% was enhancement factor. Motivation: The aim is improvement the heat transfer coefficient for cross flow heat exchanger by using medium integral finned tube. Study the effect of various water stream rate, air speed and inlet water temperature on heat transfer coefficient for them, Finding the cases which enhanced heat transfer for various ranges of air and water as well as inlet temperatures and the speed at the entrance. Develop the empirical correlations for (Nua) of smooth and medium integral finned tubes as function of (Pra) and (Rea).


2014 ◽  
Vol 552 ◽  
pp. 55-60
Author(s):  
Zheng Ming Tong ◽  
Peng Hou ◽  
Gui Hua Qin

In this article, we use BR0.3 type plate heat exchanger for experiment,and the heat transfer coefficient of the mixed plate heat exchanger is explored. Through the test platform of plate heat exchanger, a large number of experiments have been done in different mixed mode but the same passageway,and lots experimental data are obtained. By the linear fitting method and the analysis of the data, the main factors which influence the heat transfer coefficient of mixed plate heat exchanger were carried out,and the formula of heat transfer coefficient which fits at any mixed mode plate heat exchanger is obtained, to solve the problem of engineering calculation.The fact , there is no denying that the result which we get has great engineering significance


2010 ◽  
Vol 29-32 ◽  
pp. 132-137 ◽  
Author(s):  
Xue Jiang Lai ◽  
Rui Li ◽  
Yong Dai ◽  
Su Yi Huang

Flower baffle heat exchanger’s structure and design idea is introduced. Flower baffle heat exchanger has unique support structure. It can both enhance the efficiency of the heat transfer and reduce the pressure drop. Through the experimental study, under the same shell side flow, the heat transfer coefficient K which the distance between two flower baffles is 134mm is higher 3%~9% than the one of which the distances between two flower baffles are 163mm,123mm. The heat transfer coefficient K which the distance between two flower baffles is 147mm is close to the one of which the distances between two flower baffles is 134mm. The shell volume flow V is higher, the incremental quantity of heat transfer coefficient K is more. The integrated performance K/Δp of flower baffle heat exchanger which the distance between two flower baffles is 134mm is higher 3%~9% than the one of which the distances between two flower baffles are 163mm,123mm. Therefore, the best distance between two flower baffles exists between 134mm~147mm this experiment.


1998 ◽  
Vol 120 (4) ◽  
pp. 831-838 ◽  
Author(s):  
M. E. Taslim ◽  
G. J. Korotky

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of round-corner, low-aspect-ratio (ARrib = 0.667) ribs. Twelve rib geometries, comprising three rib height-to-channel hydraulic diameters (blockage ratios) of 0.133, 0.167, and 0.25 as well as three rib spacings (pitch-to-height ratios) of 5, 8.5, and 10 were investigated for two distinct thermal boundary conditions of heated and unheated channel walls. A square channel, roughened with low-aspect-ratio ribs on two opposite walls in a staggered manner and perpendicular to the flow direction, was tested. An instrumented copper rib was positioned either in the middle of the rib arrangements or in the furthest upstream location. Both rib heat transfer coefficient and channel friction factor for these low-aspect-ratio ribs were also compared with those of square ribs, reported previously by the authors. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared.


1968 ◽  
Vol 32 (11) ◽  
pp. 1127-1132,a1 ◽  
Author(s):  
Katsuto Okada ◽  
Minobu Ono ◽  
Toshio Tomimum ◽  
Hirotaka Konno ◽  
Shigemori Ohtani

Author(s):  
Florian Hoefler ◽  
Nils Dietrich ◽  
Jens von Wolfersdorf

A confined jet impingement configuration has been investigated in which the matter of interest is the convective heat transfer from the airflow to the passage walls. The geometry is similar to gas turbine applications. The setup is distinct from usual cooling passages by the fact that no crossflow and no bulk flow direction are present. The flow exhausts through two staggered rows of holes opposing the impingement wall. Hence, a complex 3-D vortex system arises, which entails a complex heat transfer situation. The transient Thermochromic Liquid Crystal (TLC) method was used to measure the heat transfer on the passage walls. Due to the nature of the experiment, the fluid as well as the wall temperature vary with location and time. As a prerequisite of the transient TLC technique, the heat transfer coefficient is assumed to be constant over the transient experiment. Therefore, additional measures were taken to qualify this assumption. The linear relation between heat flux and temperature difference could be verified for all measurement sites. This validates the assumption of a constant heat transfer coefficient which was made for the transient TLC experiments. Nusselt number evaluations from all techniques show a good agreement, considering the respective uncertainty ranges. For all sites the Nusselt numbers range within ±9% of the values gained from the TLC measurement.