scholarly journals Noninvasive Fetal Electrocardiography: Models, Technologies, and Algorithms

Author(s):  
Reza Sameni
PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0256115
Author(s):  
Carlijn Lempersz ◽  
Lore Noben ◽  
Sally-Ann B. Clur ◽  
Edwin van den Heuvel ◽  
Zhouzhao Zhan ◽  
...  

Introduction A fetal anomaly scan in mid-pregnancy is performed, to check for the presence of congenital anomalies, including congenital heart disease (CHD). Unfortunately, 40% of CHD is still missed. The combined use of ultrasound and electrocardiography might boost detection rates. The electrical heart axis is one of the characteristics which can be deduced from an electrocardiogram (ECG). The aim of this study was to determine reference values for the electrical heart axis in healthy fetuses around 20 weeks of gestation. Material and methods Non-invasive fetal electrocardiography was performed subsequent to the fetal anomaly scan in pregnant women carrying a healthy singleton fetus between 18 and 24 weeks of gestation. Eight adhesive electrodes were applied on the maternal abdomen including one ground and one reference electrode, yielding six channels of bipolar electrophysiological measurements. After removal of interferences, a fetal vectorcardiogram was calculated and then corrected for fetal orientation. The orientation of the electrical heart axis was determined from this normalized fetal vectorcardiogram. Descriptive statistics were used on normalized cartesian coordinates to determine the average electrical heart axis in the frontal plane. Furthermore, 90% prediction intervals (PI) for abnormality were calculated. Results Of the 328 fetal ECGs performed, 281 were included in the analysis. The average electrical heart axis in the frontal plane was determined at 122.7° (90% PI: -25.6°; 270.9°). Discussion The average electrical heart axis of healthy fetuses around mid-gestation is oriented to the right, which is, due to the unique fetal circulation, in line with muscle distribution in the fetal heart.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Istvan Peterfi ◽  
Lorand Kellenyi ◽  
Andras Szilagyi

Objective. The aim of the study was to develop a complex electrophysiological measurement system (hardware and software) which uses the methods of electrophysiology and provides significant information about the intrauterine status of the fetus, intending to obtain true-to-form, morphologically evaluated fetal ECG from transabdominal maternal lead.Results. The present method contains many novel ideas that allow creating true-to-form noninvasive fetal ECG in the third trimester of the pregnancy in 80% of the cases. Such ideas are the telemetric data collection, the “cleanse” of the real time recording from the maternal ECG, and the use of the cardiotocograph (CTG) that allows identifying the fetal heart events. The advantage of this developed system is that it does not require any qualified staff, because both the extraction of the information from the abdominal recording and the processing of the data are automatic.Discussion. Although the idea of a noninvasive fetal electrocardiography is more than 100 years old still there is no simple, effective, and cheap method available that would enable an extensive use. This developed system can be used in the third trimester of the pregnancy efficiently. It can produce true-to-form fetal ECGs with amplitude less than 10 µV.


2020 ◽  
Vol 13 ◽  
pp. 51-73 ◽  
Author(s):  
Radana Kahankova ◽  
Radek Martinek ◽  
Rene Jaros ◽  
Khosrow Behbehani ◽  
Adam Matonia ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document