HaptiTrack: A Novel Device for the Evaluation of Tactile Sensitivity in Active and in Passive Tasks

2021 ◽  
pp. 617-621
Author(s):  
Simone Ciotti ◽  
Matteo Bianchi ◽  
Davide Doria ◽  
Francesco Lacquaniti ◽  
Alessandro Moscatelli
Author(s):  
Domenico Pagliara ◽  
Maria Lucia Mangialardi ◽  
Stefano Vitagliano ◽  
Valentina Pino ◽  
Marzia Salgarello

Abstract Background After anterolateral thigh (ALT) flap harvesting, skin graft of the donor site is commonly performed. When the defect width exceeds 8 cm or 16% of thigh circumference, it can determine lower limb function impairment and poor aesthetic outcomes. In our comparative study, we assessed the functional and aesthetic outcomes related to ALT donor-site closure with split-thickness skin graft compared with thigh propeller flap. Methods We enrolled 60 patients with ALT flap donor sites. We considered two groups of ALT donor-site reconstructions: graft group (30 patients) with split-thickness skin graft and flap group (30 patients) with local perforator-based propeller flap. We assessed for each patient the range of motion (ROM) at the hip and knee, tension, numbness, paresthesia, tactile sensitivity, and gait. Regarding the impact on daily life activities, patients completed the lower extremity functional scale (LEFS) questionnaire. Patient satisfaction for aesthetic outcome was obtained with a 5-point Likert scale (from very poor to excellent). Results In the propeller flap group, the ROMs of hip and knee and the LEFS score were significantly higher. At 12-month follow-up, in the graft group, 23 patients reported tension, 19 numbness, 16 paresthesia, 22 reduction of tactile sensitivity, and 5 alteration of gait versus only 5 patients experienced paresthesia and 7 reduction of tactile sensitivity in the propeller flap group. The satisfaction for aesthetic outcome was significantly higher in the propeller flap group. Conclusion In high-tension ALT donor-site closure, the propeller perforator flap should always be considered to avoid split-thickness skin graft with related functional and aesthetic poor results.


2019 ◽  
Vol 9 (9) ◽  
pp. 608-613
Author(s):  
Dr. Swapna Lingaldinna,Dr. Himabindu Singh,Mona Sharma*

Objective: To measure the accuracy of a novel device in detecting Bradycardia andDesaturation (B&D) events and to determine its efficacy in resolving apneas innewborns with comparison to standard monitor (which only detects B&D eventsand alerts).Design: This was a prospective observational study.Setting: Sick Newborn Care Unit of a large tertiary referral hospital in Hyderabad,India.Methods: 31 newborns were provided with a novel device, which monitored oxygensaturation and pulse rate and alarmed when values dropped below a set thresholdwhich is referred as an event, henceforth. The novel device also provided footstimulation in response to above-mentioned events. When the monitor alarmed, anurse attended to the baby to confirm whether the baby was breathing and whetherthe event had been resolved by the device. If the event had not resolved, appropriateaction as per the standard-of-care was performed.Results: The novel device “ApneBootTM” positively detected B&D events 94.03% oftimes as compared to the standard reference monitor. 56 of 67 observed B&D eventswere visually confirmed to be apneas, indicating that 83.6% of B&D eventscoincided with apneas. Of the 56 apneic events, 50 were central apneas, of which 35were resolved by the novel device, making the device’s efficacy of apnea resolution70%.Conclusion: The results of the study indicate that this novel device “ApneBootTM”is very effective in detecting and alarming B&D events, which coincides with theapnea, and resolving it by providing foot stimulation.Keywords: Novel Device, Neonatal Apnea, Low Birth Weight, Body Temperature,Kangaroo Mother Care, Community Health,


2020 ◽  
Author(s):  
Andrés Herane-Vives

BACKGROUND “Short-term” samples are not the most appropriate for reflecting Chronic Cortisol Concentration (CCC). Although hair is used for reflecting the systemic cortisol level over “long-term”, its use appears clinically problematic. Local stress and non-stress related factors may release a circumscribed cortisol secretion that is accumulated in hair. Non-stressful earwax extraction methods may provide a more accurate specimen to measure CCC. OBJECTIVE Correlate cortisol levels using hair, serum and earwax samples METHODS Earwax from both ears of 37 controls were extracted using a clinical procedure commonly associated with local pain. One month later, earwax from the left ear side was extracted using the same procedure, and earwax from the right ear side was comfortably extracted, using an earwax self-sampling device. Participants also provided one centimetre of hair that represented the retrospective month of cortisol output, and one serum sample that reflected the effect of systemic stressors on cortisol levels. Earwax (ECC), Hair (HCC) and Serum (SCC) Cortisol Concentration were correlated and compared. Confounders´ effect on cortisol levels were studied. RESULTS Serum showed the largest and hair the lowest cortisol concentration (p<0.01). Left-ECC was larger than Right-ECC (p=0.03). Right-ECC was the only sample unaffected by confounders (all p>0.05). Right-ECC and HCC showed the only significant association (r=0.39; p=0.03). CONCLUSIONS The self-sampling device did not represent a local stressor for the ceruminous glands. It provided the cortisol level with the least likely to be affected by confounding factors over the previous month. ECC using the novel device may constitute another accurate, but more suitable and affordable specimen for measuring CCC.


2005 ◽  
Vol 41 (5) ◽  
pp. 233-236 ◽  
Author(s):  
Nathan R. Selden ◽  
Susan R. Durham ◽  
Gregory J. Anderson ◽  
Dana A.V. Braner

Open Ceramics ◽  
2021 ◽  
pp. 100089
Author(s):  
Oscar Santoliquido ◽  
Francesco Camerota ◽  
Alice Rosa ◽  
Alberto Ortona

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yuta Seki ◽  
Daisuke Nakashima ◽  
Yasuyuki Shiraishi ◽  
Toshinobu Ryuzaki ◽  
Hidehiko Ikura ◽  
...  

AbstractThe lactate threshold (LT1), which is defined as the first rise in lactate concentration during incremental exercise, has not been non-invasively and conveniently determined in a clinical setting. We aimed to visualize changes in lactate concentration in sweat during exercise using our wearable lactate sensor and investigate the relationship between the lactate threshold (LT1) and ventilatory threshold (VT1). Twenty-three healthy subjects and 42 patients with cardiovascular diseases (CVDs) were enrolled. During exercise, the dynamic changes in lactate values in sweat were visualized in real-time with a sharp continuous increase up to volitional exhaustion and a gradual decrease during the recovery period. The LT1 in sweat was well correlated with the LT1 in blood and the VT1 (r = 0.92 and 0.71, respectively). In addition, the Bland–Altman plot described no bias between the mean values (mean differences: − 4.5 and 2.5 W, respectively). Continuous monitoring of lactate concentrations during exercise can provide additional information for detecting the VT1.


2021 ◽  
Vol 92 (4) ◽  
pp. 045106
Author(s):  
R. I. Kosheleva ◽  
T. D. Karapantsios ◽  
M. Kostoglou ◽  
A. Ch. Mitropoulos

Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4027
Author(s):  
Timo Lauteslager ◽  
Michal Maslik ◽  
Fares Siddiqui ◽  
Saad Marfani ◽  
Guy D. Leschziner ◽  
...  

Respiratory rate (RR) is typically the first vital sign to change when a patient decompensates. Despite this, RR is often monitored infrequently and inaccurately. The Circadia Contactless Breathing Monitor™ (model C100) is a novel device that uses ultra-wideband radar to monitor RR continuously and un-obtrusively. Performance of the Circadia Monitor was assessed by direct comparison to manually scored reference data. Data were collected across a range of clinical and non-clinical settings, considering a broad range of user characteristics and use cases, in a total of 50 subjects. Bland–Altman analysis showed high agreement with the gold standard reference for all study data, and agreement fell within the predefined acceptance criteria of ±5 breaths per minute (BrPM). The 95% limits of agreement were −3.0 to 1.3 BrPM for a nonprobability sample of subjects while awake, −2.3 to 1.7 BrPM for a clinical sample of subjects while asleep, and −1.2 to 0.7 BrPM for a sample of healthy subjects while asleep. Accuracy rate, using an error margin of ±2 BrPM, was found to be 90% or higher. Results demonstrate that the Circadia Monitor can effectively and efficiently be used for accurate spot measurements and continuous bedside monitoring of RR in low acuity settings, such as the nursing home or hospital ward, or for remote patient monitoring.