Staged External Fixation Protocol in Treatment of Complex Limb Trauma

Author(s):  
A. Lerner ◽  
S. Kalfa
2020 ◽  
Author(s):  
Khalil Amri ◽  
Ahmed Tounsi ◽  
Achraf Oueslati ◽  
Mouhamed Ben Salah ◽  
Rim Dhahri ◽  
...  

Abstract Background: In conflicting areas, orthopaedic surgeons adopted this concept of damage control orthopaedic (DCO) to face limb fracture due to ballistic trauma because of the gravity of the hurts, the limitation of equipment, and precarious conditions of asepsis. They use external fixation as an initial treatment at the nearest health centre. They delay the definitive treatment to be realized in better conditions. Our study aims to assess the outcome of the damage control orthopaedic (DCO) strategy in military ballistic limb trauma according to the experience of the Military Hospital of Tunisia.Materials and methods: This study is a retrospective study on patients who were hospitalized for a limb ballistic fracture. It includes military patients treated urgently with primary external fixation at the nearest health centre. We adapted the Gustilo classification to describe wound opening, the Winquist and Hansen classification to define fracture comminution and the grading system for bone loss to evaluate bone loss. Then, all victims were evacuated secondary to the military hospital to receive the definitive treatments. The conversion to internal osteosynthesis had taken place according to some criteria. They were the absence of local sepsis, a haemoglobin level (> 10 g/dl), a serum protein level (> 50 g/l) and negative or falling CRP kinetics. We studied the delay of conversion from external fixation to internal osteosynthesis, bone healing time and complications.Result: Our study included 32 patients, all men, with a mean age of 31 years. The average follow-up was 33.2 months. Eighty-eight percent of trauma concerned the lower limb. The average delay for conversion from external fixation to internal osteosynthesis was 7.8 days. Bone union was achieved in 26 cases, with an average delay of 4.23 months. The observed general complications were anaemia, pulmonary embolism and rhabdomyolysis. Local complications were essentially sepsis on osteosynthesis material and pseudarthrosis. These complications were significantly associated with a type III Gustilo skin opening, a type III and IV Winquist fracture comminution, a type II and III Grading system for bone loss, and a delay in conversion from external fixation to internal osteosynthesis.Conclusion: DCO is a global strategy that involves all measures participating in the acceleration of wound healing and fighting against infection. These measures shorten the delay of conversion from external fixation into internal osteosynthesis, which constitutes a key parameter in the management of limb fracture due to ballistic trauma.


2020 ◽  
Author(s):  
Amri Khalil ◽  
Tounsi Ahmed ◽  
Oueslati Achraf ◽  
Ben Salah Mouhamed ◽  
Dhahri Rim ◽  
...  

Abstract Background: In conflict areas, orthopaedic surgeon adopted this concept of damage control orthopaedic (DCO) to face limb fracture due to ballistic trauma because of the gravity of the hurts, the limitation of equipment, and precarious conditions of asepsis. They use external fixation as an initial treatment at the nearest health centre. And they delay the definitive treatment to be realized in better conditions. Our study aims to assess the outcome of damage control orthopaedic (DCO) strategy in military ballistic limb trauma according to the experience of the Military Hospital of Tunisia. Materials and methods: This study is a retrospective study on patients who were hospitalized for a limb ballistic fracture. It includes military patients treated urgently with primary external fixation at the nearest health centre. We adapted Gustilo classification to describe the wound opening, Winquist and Hansen classification to define the fracture comminution and Grading system for bone loss to evaluate the bone loss. Then all victims were evacuated secondary, to the Military hospital to receive the definitive treatments. The conversion to internal osteosynthesis had taken place according to some criteria. They were the absence of local sepsis, a haemoglobin level (> 10 g/dl), a serum protein level (> 50 g/l) and a negative or falling CRP kinetics. We studied the delay of conversion from external fixation to an internal osteosynthesis, bone healing time and complications. Result: Our study included 32 patients, all men, mean age was 31 years. The average follows up was 33,2 months. 88% of trauma concerned lower limb. The average delay for conversion from external fixation to internal osteosynthesis was 7,8 days. The bone union was achieved in 26 cases, with an average delay of 4.23 months. Observed general complications were anaemia, pulmonary embolism and rhabdomyolysis. Local complications were essentially sepsis on osteosynthesis material and pseudarthrosis. These complications were significantly associated with a type III of Gustilo skin opening, a type III and IV of the Winquist fracture comminutions, a type II and III of the Grading system for bone loss, and the delay for conversion from external fixation to internal osteosynthesis. Conclusion: DCO is a global strategy which involves all measures participating in the acceleration of the wound healing and fighting against the infection. These measures shorten the delay of conversion from external fixation into an internal osteosynthesis, which constitutes a key parameter in the management of limb fracture due to ballistic trauma.


2020 ◽  
Vol 99 (8) ◽  

Introduction: The study compares the results of open reduction using volar locking plates with ligamentotaxis by external fixation in fractures of distal radius type 2R3C according to AO classification. Methods: A retrospective study evaluating the results of osteosynthesis in patients with distal radius fractures type 2R3C according to AO classification, operated until December 2018. The ORIF method with volar locking plates (LCP) was used in 54 patients, and closed reduction with ligamentotaxis using external fixation (EF) was used in 33 patients. The mean age of the patients was 46.7 years in the LCP group and 59.6 years in the EF group. All were evaluated for their X-ray and functional outcomes and according to the Green and O’Brien score at 6 and 12 months after surgery. Results: According to X-rays at 12 months in the LCP group, the mean sagittal tilt was 10.13°, the mean radial inclination was 23.89°, and the mean radial length was 11.84 mm. In the EF group, the mean sagittal tilt was 6.32°, the mean radial inclination was 24.78°, and the mean radial length was 9.89 mm. According to the Green and O’Brien score, we recorded a mean score of 84.44 points in the LCP group at 12 month; we achieved good and excellent results in 83.33% of the patients and no poor result was observed. In the EF group the final mean score was 77.27; good and excellent results were achieved in 45.46% of the patients and a poor result in one patient. Conclusion: Based on the results in our group of patients, the internal type osteosynthesis using LCP implants can be recommended as a first-choice technique in the treatment of 2R3C fractures according to AO classification.


2013 ◽  
Vol 22 (04) ◽  
pp. 316-320 ◽  
Author(s):  
Robert K. Lark ◽  
John S. Lewis Jr. ◽  
Tyler Steven Watters ◽  
Robert D. Fitch

2020 ◽  
Author(s):  
Hongfeng Sheng ◽  
Weixing Xu ◽  
Bin Xu ◽  
Hongpu Song ◽  
Di Lu ◽  
...  

UNSTRUCTURED The retrospective study of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures provides a theoretical basis for the application of this technology. The paper collected 28 patients with tibiofibular fractures from the Department of Orthopaedics in our hospital from March 2015 to June 2018. After the treatment, the follow-up evaluation of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures and concurrency the incidence of the disease, as well as the efficacy and occurrence of the internal fixation of the treatment of tibial fractures in our hospital. The results showed that Taylor's three-dimensional external fixator was superior to orthopaedics in the treatment of tibiofibular fractures in terms of efficacy and complications. To this end, the thesis research can be concluded as follows: Taylor three-dimensional external fixation in the treatment of tibiofibular fractures is more effective, and the incidence of occurrence is low, is a new technology for the treatment of tibiofibular fractures, it is worthy of clinical promotion.


Sign in / Sign up

Export Citation Format

Share Document