External Fixation and Osteogenesis Progress Tracking Out in Use to Control Condition and Mechanical Environment of the Broken Bone Adhesion Zone

2007 ◽  
pp. 211-215
Author(s):  
D. Kołodziej ◽  
D. Jasińska-Choromańska
2020 ◽  
Vol 99 (8) ◽  

Introduction: The study compares the results of open reduction using volar locking plates with ligamentotaxis by external fixation in fractures of distal radius type 2R3C according to AO classification. Methods: A retrospective study evaluating the results of osteosynthesis in patients with distal radius fractures type 2R3C according to AO classification, operated until December 2018. The ORIF method with volar locking plates (LCP) was used in 54 patients, and closed reduction with ligamentotaxis using external fixation (EF) was used in 33 patients. The mean age of the patients was 46.7 years in the LCP group and 59.6 years in the EF group. All were evaluated for their X-ray and functional outcomes and according to the Green and O’Brien score at 6 and 12 months after surgery. Results: According to X-rays at 12 months in the LCP group, the mean sagittal tilt was 10.13°, the mean radial inclination was 23.89°, and the mean radial length was 11.84 mm. In the EF group, the mean sagittal tilt was 6.32°, the mean radial inclination was 24.78°, and the mean radial length was 9.89 mm. According to the Green and O’Brien score, we recorded a mean score of 84.44 points in the LCP group at 12 month; we achieved good and excellent results in 83.33% of the patients and no poor result was observed. In the EF group the final mean score was 77.27; good and excellent results were achieved in 45.46% of the patients and a poor result in one patient. Conclusion: Based on the results in our group of patients, the internal type osteosynthesis using LCP implants can be recommended as a first-choice technique in the treatment of 2R3C fractures according to AO classification.


2013 ◽  
Vol 22 (04) ◽  
pp. 316-320 ◽  
Author(s):  
Robert K. Lark ◽  
John S. Lewis Jr. ◽  
Tyler Steven Watters ◽  
Robert D. Fitch

2020 ◽  
Author(s):  
Hongfeng Sheng ◽  
Weixing Xu ◽  
Bin Xu ◽  
Hongpu Song ◽  
Di Lu ◽  
...  

UNSTRUCTURED The retrospective study of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures provides a theoretical basis for the application of this technology. The paper collected 28 patients with tibiofibular fractures from the Department of Orthopaedics in our hospital from March 2015 to June 2018. After the treatment, the follow-up evaluation of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures and concurrency the incidence of the disease, as well as the efficacy and occurrence of the internal fixation of the treatment of tibial fractures in our hospital. The results showed that Taylor's three-dimensional external fixator was superior to orthopaedics in the treatment of tibiofibular fractures in terms of efficacy and complications. To this end, the thesis research can be concluded as follows: Taylor three-dimensional external fixation in the treatment of tibiofibular fractures is more effective, and the incidence of occurrence is low, is a new technology for the treatment of tibiofibular fractures, it is worthy of clinical promotion.


2020 ◽  
Vol 48 (4) ◽  
pp. 030006052092040
Author(s):  
Yao Lu ◽  
Teng Ma ◽  
Cheng Ren ◽  
Zhong Li ◽  
Liang Sun ◽  
...  

Objective To evaluate the effectiveness of bone transport involving circular external fixation and locking plate application for the treatment of segmental tibial defects. Methods A retrospective review of 12 patients with segmental tibial defects who underwent bone transport with circular external fixation and locking plate application. We evaluated external fixation time, external fixation index, time to achieve union, and complications. Clinical results were assessed using the Association for the Study and Application of the Methods of Ilizarov (ASAMI) score. Generic health-related outcome was assessed using the 36-Item Short-Form Health Survey questionnaire (SF-36). Results The mean follow-up was 25.8 months, and the mean defect size was 6.7 cm. All of the patients achieved union at the distraction callus and docking site. The average external fixation time was 299.5 days. The mean external fixation index was 16.5 days/cm, and the mean healing index was 44.9 days/cm. The functional outcomes were excellent in eight cases and good in four. The average SF-36 score was 92. Conclusion Bone transport with external fixation and locking plate application may be a promising method for the treatment of segmental tibial defects.


Sign in / Sign up

Export Citation Format

Share Document