Principal Subspace Analysis Based BCG Artifact Removal in Single Channel EEG Signal Measured Inside MRI Scanner

Author(s):  
Tahir Rasheed ◽  
Young-Koo Lee ◽  
Sungyoung Lee
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ajay Kumar Maddirala ◽  
Kalyana C Veluvolu

AbstractIn recent years, the usage of portable electroencephalogram (EEG) devices are becoming popular for both clinical and non-clinical applications. In order to provide more comfort to the subject and measure the EEG signals for several hours, these devices usually consists of fewer EEG channels or even with a single EEG channel. However, electrooculogram (EOG) signal, also known as eye-blink artifact, produced by involuntary movement of eyelids, always contaminate the EEG signals. Very few techniques are available to remove these artifacts from single channel EEG and most of these techniques modify the uncontaminated regions of the EEG signal. In this paper, we developed a new framework that combines unsupervised machine learning algorithm (k-means) and singular spectrum analysis (SSA) technique to remove eye blink artifact without modifying actual EEG signal. The novelty of the work lies in the extraction of the eye-blink artifact based on the time-domain features of the EEG signal and the unsupervised machine learning algorithm. The extracted eye-blink artifact is further processed by the SSA method and finally subtracted from the contaminated single channel EEG signal to obtain the corrected EEG signal. Results with synthetic and real EEG signals demonstrate the superiority of the proposed method over the existing methods. Moreover, the frequency based measures [the power spectrum ratio ($$\Gamma $$ Γ ) and the mean absolute error (MAE)] also show that the proposed method does not modify the uncontaminated regions of the EEG signal while removing the eye-blink artifact.


Author(s):  
Muhammad Afif Hendrawan ◽  
Pramana Yoga Saputra ◽  
Cahya Rahmad

Nowadays, biometric modalities have gained popularity in security systems. Nevertheless, the conventional commercial-grade biometric system addresses some issues. The biggest problem is that they can be imposed by artificial biometrics. The electroencephalogram (EEG) is a possible solution. It is nearly impossible to replicate because it is dependent on human mental activity. Several studies have already demonstrated a high level of accuracy. However, it requires a large number of sensors and time to collect the signal. This study proposed a biometric system using single-channel EEG recorded during resting eyes open (EO) conditions. A total of 45 EEG signals from 9 subjects were collected. The EEG signal was segmented into 5 second lengths. The alpha band was used in this study. Discrete wavelet transform (DWT) with Daubechies type 4 (db4) was employed to extract the alpha band. Power spectral density (PSD) was extracted from each segment as the main feature. Linear discriminant analysis (LDA) and support vector machine (SVM) were used to classify the EEG signal. The proposed method achieved 86% accuracy using LDA only from the third segment. Therefore, this study showed that it is possible to utilize single-channel EEG during a resting EO state in a biometric system.


Fractals ◽  
2009 ◽  
Vol 17 (04) ◽  
pp. 473-483
Author(s):  
BEHZAD AHMADI ◽  
BAHAREH ZAGHARI ◽  
RASSOUL AMIRFATTAHI ◽  
MOJTABA MANSOURI

This paper proposes an approach for quantifying Depth of Anesthesia (DOA) based on correlation dimension (D2) of electroencephalogram (EEG). The single-channel EEG data was captured in both ICU and operating room while different anesthetic drugs, including propofol and isoflurane, were used. Correlation dimension was computed using various optimized parameters in order to achieve the maximum sensitivity to anesthetic drug effects and to enable real time computation. For better analysis, application of adaptive segmentation on EEG signal for estimating DOA was evaluated and compared to fixed segmentation, too. Prediction probability (PK) was used as a measure of correlation between the predictors and BIS index to evaluate the proposed methods. Appropriate correlation between DOA and correlation dimension is achieved while choosing (D2) parameters adaptively in comparison to fixed parameters due to the nonstationary nature of EEG signal.


Sign in / Sign up

Export Citation Format

Share Document