Quality Control of Platelet Concentrates during Storage using different Forms of Agitation Measuring the Platelet Activation

Author(s):  
M. K. Siemensen ◽  
V. Wilckens ◽  
F. Duka ◽  
M. M. Magens ◽  
P. Kuehnl ◽  
...  
PLoS ONE ◽  
2017 ◽  
Vol 12 (2) ◽  
pp. e0172265 ◽  
Author(s):  
Cécile H. Kicken ◽  
Mark Roest ◽  
Yvonne M. C. Henskens ◽  
Bas de Laat ◽  
Dana Huskens

Author(s):  
K. Gutensohn ◽  
U. Cassens ◽  
C. Peters ◽  
I. Ganschow ◽  
W. Zeller ◽  
...  

1995 ◽  
Vol 21 (S 02) ◽  
pp. 91-95 ◽  
Author(s):  
Markus Böck ◽  
Joachim Groh ◽  
Anle Glaser ◽  
Klaus Storck ◽  
Michael Kratzer ◽  
...  

Quality control of platelet concentrates (PC) is an important prerequisite for good transfusion praxis. However, direct measurement of platelet function is complex, since available methods (e.g. aggregometry, serotonin release) are time consuming and require special equipment. Therefore a test system is needed, which is easy to handle, fast, and achieves reliable results. The present paper compares the results of conventional platelet function tests with those of a modified in-vitro bleeding test (IVBT) (Thrombostat 4000) in liquid-stored and cryopreserved PCs. A high correlation between aggregometry, serotonin release, GMP 140 expression upon stimulation, and IVBT was demonstrated. Therefore IVBT seems to be a good alternative to the conventional platelet function tests for quality control of PCs. In addition, a good correlation between the results of IVBT of patients’ blood after PC transfusion and IVBT of patients blood before transfusion supplemented with platelets of the respective PC could be found. Therefore IVBT seems to be able to predict PC transfusion success. However, since these data were obtained in a small sample undergoing bone marrow transplantation, further studies are needed to verify this hypothesis.


1993 ◽  
Vol 16 (5_suppl) ◽  
pp. 130-134 ◽  
Author(s):  
F. Schooneman

The Excel Cell Separator produced by Dideco represents a good compromise between automation and Platelet efficiency. Platelet activation is a phenomenon that we can find with the concentrates of all cell separators. Although, the complement activation of Excel is extremely lower in comparison with the same data obtained using all the other cell separators, the 5-day storage is acceptable. It will be important to research the bacteriological controls. Like the pH of the platelet bags, because in certain cases it was too low. For the future it will be interesting to study the possibility to predict the quantity of platelets collected having a system that is adaptable with the donor parameters.


Transfusion ◽  
1990 ◽  
Vol 30 (7) ◽  
pp. 634-638 ◽  
Author(s):  
R Fijnheer ◽  
RN Pietersz ◽  
D Korte ◽  
CW Gouwerok ◽  
WJ Dekker ◽  
...  

2013 ◽  
Vol 40 (2) ◽  
pp. 101-107 ◽  
Author(s):  
Josef Neumüller ◽  
Claudia Meisslitzer-Ruppitsch ◽  
Adolf Ellinger ◽  
Margit Pavelka ◽  
Christof Jungbauer ◽  
...  

Blood ◽  
2008 ◽  
Vol 112 (11) ◽  
pp. 996-996
Author(s):  
Valery Leytin ◽  
David J. Allen ◽  
Asuman Mutlu ◽  
Sergiy Mykhaylov ◽  
Elena Lyubimov ◽  
...  

Abstract Platelet storage lesion is a serious problem limiting clinical use of platelet concentrates (PC) after extended and long-term storage. Platelet activation is a well-known manifestation of platelet storage lesion. However, over the last decade, platelet apoptosis has been also recognized in stored PCs and in platelets following exposure to thrombin, calcium ionophores, anti-platelet antibodies and very high shear stresses. The aim of this study was to elucidate the contribution of platelet activation and apoptosis to the platelet storage lesion during conventional (Days 2–5), extended (Days 6–8) and long-term (Days 11–16) PC storage. We prepared seven prestorage-leukoreduced PC by the platelet-rich plasma (PRP) method, stored PC for 2–16 days at 22°C, and used flow cytometry for determining platelet activation as P-selectin (CD62) exposure and platelet apoptosis as depolarization of mitochondrial inner membrane potential (ΔΨm), activation of executioner caspase-3, exposure of phosphatidylserine (PS) and release of apoptotic platelet fragments microparticles (MP). Platelet activation and apoptotic responses were also determined in fresh (Day 0) PRP using thrombin titration. We found a significant increase of platelet activation under conventional PC storage for 2–5 days (38.6 ± 3.1% CD62 positive cells, P < 0.0001). With extended (Days 6–8) storage, platelet activation was increased to 66.5 ± 5.3% and reached the maximal level of 92.0 ± 1.1% after 11–12 storage days (P < 0.0001). In contrast, ΔΨm depolarization and caspase-3 activation did not increase in comparison with Day 0 platelets, even after PC storage for 12 days (P > 0.05) and storage for 13–16 days was required for significant triggering these apoptotic events (P < 0.05-0.0001). Similarly, although we observed a slight increase of PS exposure (5–10%) and MP release (9–11%) during PC storage for 2–12 days, incubation for 13–16 days was required for a stronger (30–60%) stimulation of these apoptotic manifestations (P < 0.001-0.0001). Paired comparison between the effects of PC storage on CD62 exposure and apoptotic events clearly demonstrated for all storage times a significantly higher level of platelet activation than levels of ΔΨm depolarization, caspase-3 activation, PS exposure and MP release (P < 0.01-0.0001). Furthermore, we found that when fresh (Day 0) PRP was treated with different thrombin doses, ranging from 0.05 to 10 U/ml, a much higher maximal level of platelet activation (~90%) was reached, in comparison to the level of apoptosis (30–40%), and 100- to 200-fold lower dose of thrombin were required for maximal induction of activation (0.05–0.1 U/ml) than for stimulation of apoptosis (10 U/ml). Taken together, these data indicate that (i) during PC storage, platelet activation is triggered much earlier than platelet apoptosis, (ii) platelet activation rather than apoptosis contributes most to the platelet storage lesion during conventional (Days 2–5) and extended (Days 6–8) PC storage whereas during long-term (Days 13–16) storage both responses are involved in platelet deterioration, and (iii) platelet activation and apoptosis are different phenomena; they may be induced by different mechanisms and/or require quite different levels of triggering stimuli.


Sign in / Sign up

Export Citation Format

Share Document