Effects of Electric Current Application on the Evoked Spinal Cord Potentials in Dogs

Author(s):  
T. Kano ◽  
A. Hashiguchi
2018 ◽  
Author(s):  
Jennifer M. Miller ◽  
Roche C. de Guzman

AbstractControlled drug delivery systems such as the stimulation-based biomaterial scaffolds for sequestration and release of drugs offer safety and regulated therapeutic approach. In this study, the drug:para-aminobenzoic acid (PABA) was absorbed into a crosslinked chitosan and poly(caprolactone) (PCL) hydrogel and its release kinetics quantified under different conditions. It was experimentally-observed that the higher the pH (or the more basic the pH), the slower the PABA saturation release trended over time. At the acidic environment of pH 4, PABA was released the fastest, and enhanced by the degradation of chitosan-PCL gel. When a constant electric current of 0.6 mA sa applied, PABA release was induced at pH 10. However, at pH 7, PABA was stably-bound to the chitosan-PCL matrix, with or without the external current. The selective sequestration of PABA at basic pH and its stimulated release via electric current application can be further explored for clinical translatability.


1974 ◽  
Vol 41 (2) ◽  
pp. 217-223 ◽  
Author(s):  
Sanford J. Larson ◽  
Anthony Sances ◽  
Donald H. Riegel ◽  
Glenn A. Meyer ◽  
Donald E. Dallmann ◽  
...  

✓ In 18 patients with cancer and intractable pain, capacitatively coupled pulses of 0.25 msec duration were delivered transcutaneously at 100 Hz to sets of five in-line electrodes implanted subdurally over the dorsal columns. Averaged somatosensory-evoked potentials were recorded from scalp electrodes before, during, and after application of current. All but one patient experienced relief of pain during stimulation, persisting for as long as several hours afterward. Eleven patients developed hyperactive deep reflexes, pathological reflexes, and decreased perception of joint rotation, pain, and touch below the level of current application. Somatosensory-evoked potential amplitudes were markedly reduced. All neurological findings returned to control values within 1 hour after each of repeated applications of current. Histological examination of spinal cord sections from four cancer patients showed no changes secondary to long-term current application. Similar currents were applied to the spinal cord of 15 monkeys with chronically implanted bipolar recording or stimulating electrodes over the lower, middle, and upper thoracic cord, in nucleus ventralis posterior lateralis (VPL), and over the sensory motor cortex (SMC). With application of current, the responses in VPL and SMC to peripheral stimulation were abolished. Evoked potential responses were abolished between bipolar stimulating electrodes and bipolar recording electrodes separated by the five in-line electrodes used to supply the 100 Hz current. However, when both stimulating and recording electrodes were either above or below the five in-line electrode set, evoked responses were unaffected. The findings indicate that applied currents blocked neuronal transmission by producing local changes in the cord. The prolonged alteration of cerebral evoked potentials and relief of pain, however, could also be related to involvement of supraspinal neurons.


2002 ◽  
Vol 14 (8) ◽  
pp. 471 ◽  
Author(s):  
R. T. Tecirlioglu ◽  
O. Lacham-Kaplan ◽  
A. O. Trounson

The effects of electric current (in vivo and in vitro) and seminal plasma on epididymal and ejaculated sperm obtained from C57BL × CBA and C57BL/6J mice were investigated by studying motility parameters, fertilization and embryo development. Electroejaculates were obtained by applying a series of computer-generated sinusoidal alternating currents (0.25–3.0 V at 50 Hz) delivered for 1, 2 and 3 s with 1-s rest periods using a four-electrode rectal probe for 4 min. Epididymal sperm obtained from the same mice were either subjected to electric current in vitro in a Plexiglass chamber or incubated in a medium containing seminal plasma for 2 h. In vitro electric current application and incubation in a medium containing seminal plasma significantly (P<0.01) decreased sperm motility. Neither electroejaculates nor epididymal spermatozoa incubated with seminal plasma could fertilize oocytes by conventional IVF (P<0.001), whereas sperm subjected to in vitro electric current had lost little of their ability to fertilize oocytes. Following transfer of embryos generated by intracytoplasmic sperm injection (ICSI), the number of live pups obtained from electroejaculated sperm (10.2%; 6/59) was significantly (P<0.01) lower than from epididymal sperm (50.0%; 22/42). Electroejaculation using a rectal probe had little effect on motility and fertilization capacity of mouse epididymal sperm, whereas the presence of seminal plasma decreased motility and prevented fertilization.


Author(s):  
Vladislav Eltishchev ◽  
Sergei Mandrykin ◽  
Ilya Kolesnichenko

Abstract The electro-vortex flow of liquid metal in a cylindrical cell, placed into external vertical magnetic field, in case of axial electric current application is studied numerically and experimentally. The results are compared to those previously obtained in case of a localized electric current application. In the absence of the external magnetic field, the comparison shows no qualitative change in the flow structure. In presence of the external magnetic field, a poloidal motion is suppressed. A critical magnetic field of poloidal suppression is shown to be approximately 50% higher in case of axial electric current application.


1956 ◽  
Vol 185 (2) ◽  
pp. 325-331 ◽  
Author(s):  
Warren S. Rehm

Using the chambered gastric segment preparation it was found that application of current from serosa to mucosa resulted in an increase in H+ ion production and a decrease in Cl– ion secretion. Following the application of current from serosa to mucosa the secretory rate was essentially the same as before current application. Application of current from mucosa to serosa resulted in a decrease in H+ ion secretion and during the first 10-minute period sometimes an increase and sometimes a decrease in Cl– ion output. With continued application currents from mucosa to serosa, both the H+ ion and Cl– ion secretory rates continued to decline. Following cessation of current from mucosa to serosa the secretory rate was less than before current application. The implications of these findings are discussed in the light of a theory of HCl formation.


Sign in / Sign up

Export Citation Format

Share Document