Full-Scale Experimental Study on Fire Suppression Performance of a Water Mist System for Large Shipboard Machinery Spaces

2016 ◽  
pp. 877-886
Author(s):  
Xiaowei Wu ◽  
Shouxiang Lu
2012 ◽  
Vol 30 (2) ◽  
pp. 138-157 ◽  
Author(s):  
Na Meng ◽  
Longhua Hu ◽  
Shuai Liu ◽  
Long Wu ◽  
Longfei Chen ◽  
...  

2013 ◽  
Vol 790 ◽  
pp. 53-56
Author(s):  
Chen Jian ◽  
Xu Yan Ying ◽  
Wang Na

This paper presents an experimental study of fire suppression effectiveness with water mist containing FeCl2 additives.The investigation focuses on suppression effectiveness under various FeCl2 additives concentrations,working pressures and nozzle different height above the fire source . The experimental results show that: there is a significant impact on fire suppression effectiveness when adding FeCl2 to water mist. There is an optimum additive concentration of extinguishing fire, corresponding to the shortest extinguishing time, the least amount of water, the highest efficiency of extinguishing fire. The nozzle working pressures and nozzle position have effect on the performance of the water mist extinguishing: the greater the pressure is, the shorter water mist fire extinguishing time is. Under the same experimental conditions, the closer the water mist nozzles are to the oil pan, the shorter extinguishing time is.


2001 ◽  
Author(s):  
G. Su ◽  
J. G. Quintiere ◽  
N. Schultz

Abstract The objective of the project is to develop water mist extinguishments design by scaling. The report describes the requirement and criteria of scaling fire, scale model, and the results of suppression for a developing water mist system design. The Maritime Safety Committee Draft Circular, MSC 914 is used as a basis test to evaluate a water mist design. A series of three full-scale tests related to MSC 914 were performed: fire only, fire with steel trailers, and fire with steel trailers and combustible commodities. A simulation was accordingly studied. Then, a scaled water mist design was tested in the scale model to find the characteristics needed for suppression in terms of pressure, water flow rate, droplet size, and the spray momentum. Based on these characteristics, a candidate nozzle will be selected for the full-scale MSC 914 test. The results so far show that the water mist system can effectively suppress the fire in scaled MSC 914 model. The full-scale MSC 914 is scheduled for September 2001. Therefore, the final answer is still pending until then. Scaling results are confirmed for temperatures, heat flux and flow for the MSC 914 fire without water add in.


2012 ◽  
Vol 166-169 ◽  
pp. 2804-2809 ◽  
Author(s):  
Jian Chen

Abstract. The effects of flow coefficients, working pressures and different spray distances on extinguishing cooking oil fires by water mist were studied by experiment. The results show that the fire suppression effectiveness is increased with the increase of flow coefficient and working pressure, spray distance also affects the fire extinguishment efficiency of water mist. Reasonable conditions and designing parameters for practical engineering application of water mist are suggested.