Experimental study on the pulse water mist fire suppression system performance in a confined space

Author(s):  
P. Y. Lun ◽  
Q. Zhang ◽  
X. K. Li
2021 ◽  
Vol 15 (2) ◽  
Author(s):  
Wira Setiawan ◽  
Distyan Kotanjungan

Based on statistical data in recent years, there are still quite a number of ship accidents due to fires, including on passenger ships. The water mist system is a fire suppression system that allows it to be used in the engine room with the advantage that it can keep the heat production rate low during the extinguishing process and can be operated earlier than the CO2 system. The research is conducted by using fire dynamic simulator in the engine room of a 300 GT ferry ro-ro passenger to compare the heat release rate of fire without an extinguishing system, an existing CO2 system, and a water mist system. The result shows that the CO2 fire suppression system reduces the heat release rate more rapidly to the decay phase at 375 seconds while the water mist takes more than 900 seconds. However, the fully developed phase of the water mist suppression system occurs more quickly than CO2 because the sprinklers are activated shortly after a fire occurs. Unlike water mist, the CO2 system is activated at 60 seconds so that the pre-combustion, growth, flashover, and fully developed phases are at the same HRR and time as the natural one.


2013 ◽  
Vol 790 ◽  
pp. 53-56
Author(s):  
Chen Jian ◽  
Xu Yan Ying ◽  
Wang Na

This paper presents an experimental study of fire suppression effectiveness with water mist containing FeCl2 additives.The investigation focuses on suppression effectiveness under various FeCl2 additives concentrations,working pressures and nozzle different height above the fire source . The experimental results show that: there is a significant impact on fire suppression effectiveness when adding FeCl2 to water mist. There is an optimum additive concentration of extinguishing fire, corresponding to the shortest extinguishing time, the least amount of water, the highest efficiency of extinguishing fire. The nozzle working pressures and nozzle position have effect on the performance of the water mist extinguishing: the greater the pressure is, the shorter water mist fire extinguishing time is. Under the same experimental conditions, the closer the water mist nozzles are to the oil pan, the shorter extinguishing time is.


2007 ◽  
Vol 92 (5) ◽  
pp. 747-751 ◽  
Author(s):  
Jianghong Liu ◽  
Jun Qin ◽  
Xin Huang ◽  
Guangxuan Liao

2011 ◽  
Vol 14 (2) ◽  
Author(s):  
Danardono A. Sumarsono ◽  
Yulianto S. Nugroho ◽  
Mariance , ◽  
I Gede Wahyu W. Ariasa

2017 ◽  
Vol 170 ◽  
pp. 344-351 ◽  
Author(s):  
Fitri Pancawardani ◽  
Dwi Arini ◽  
Randy Putra Yunindar ◽  
Mohamad Lutfi Ramadhan ◽  
Fahri Ali Imran ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document