Estimation of Mobilized Shaft Resistance of Bored Piles from Pile Load Test

2021 ◽  
pp. 639-649
Author(s):  
Gouthami Manthena ◽  
Srinivas Kadali ◽  
Madhav Madhira
2020 ◽  
Vol 26 (2) ◽  
pp. 144-158
Author(s):  
ALI MAJID AL-KINANI ◽  
Mahmood D. Ahmed

 Bored piles settlement behavior under vertical loaded is the main factor that affects the design requirements of single or group of piles in soft soils. The estimation of bored pile settlement is a complicated problem because it depends upon many factors which may include ground conditions, validation of bored pile design method through testing and validation of theoretical or numerical prediction of the settlement value. In this study, a prototype single and bored pile group model of arrangement (1*1, 1*2 and 2*2) for total length to diameter ratios (L/D) is 13.33 and clear spacing three times of diameter, subjected to vertical axial loads. The bored piles model used for the test was 2000 mm in length, and 150 mm in diameter has been constructed in soft clayey soils.  Furthermore, different theoretical methods have been used for the estimation of bored pile settlement, such as Poulos and Vesic's methods and then their comparison with the pile load test data based on the quick pile load test as presented in (ASTM-D1143, 2007).   In general, the theoretical method for estimation the bored pile settlement by Poulos and Vesic's gives higher value of the settlement for the single and group bored pile compared to the pile settlement results obtained from field pile load test data. Therefore, it is not recommended to be used for soft clayey soils. On the other hand, Hansen’s 90% and Butler and Hoy’s results may be considered reliable interpretation method to compute the settlement of single and group bored pile.  


2017 ◽  
Vol 107 ◽  
pp. 00033
Author(s):  
Ľubomír Prekop
Keyword(s):  

2015 ◽  
Vol 813-814 ◽  
pp. 1126-1130
Author(s):  
G. Kesavan ◽  
S.S. Chandrasekaran

The maximum load carrying capacity of bored piles is a complex problem because it is a function of a number of factors, these factors include methods of soil exploration, ground water condition, types of grading of concrete, quantity and quality of concrete. The knowledge of Geotechnical test is important for the most economical design of the piles. This paper describes some important aspects of field investigation, design and construction of in-situ bored pile foundation, field pile load test of experience gained from the construction of the pile at a site in Aathoor in Tamil Nadu, India. The site was fully sandy soil from existing ground level. The design of bored pile under axial compression was done using Empirical formula, pile load test and by using PLAXIS 2D software. Results were compared with vertical load and settlement in this site.


1985 ◽  
Vol 22 (4) ◽  
pp. 592-599
Author(s):  
R. G. Horvath

A multiple loading testing method is suggested, which permits testing a single drilled pier foundation under three different conditions of load support. The pier may be tested under conditions of combined shaft and end-bearing resistance, end-bearing resistance only, and shaft resistance only. The advantages of this multiple loading test method include observation of the load-transfer and displacement behaviours of the pier under these three different support conditions and verification of the values obtained for the components of load support, i.e., shaft and end-bearing resistance, all from a single test pier.A special base load cell capable of performing a different function during each cycle of loading is required. A suitable load cell, consisting of a series of Freyssi flatjacks, and the method of operation are described.A multiple loading test procedure was used successfully as part of a field investigation program on full-scale pier sockets in weak shale. Data on the load-displacement behaviour of the pier tested using the multiple loading method are reported. Information concerning piers tested using conventional single loading methods are provided for comparison.The multiple loading test results were in good agreement with results obtained from conventional testing methods. Thus the multiple loading test method provides an economical means of obtaining a large amount of design information for drilled pier foundation systems, using a single test pier. Key words: field load test, multiple loading, drilled piers and caissons, shaft resistance, end-bearing resistance, combined shaft and end-bearing resistances, base load cell, shale.


2011 ◽  
Vol 243-249 ◽  
pp. 4402-4407
Author(s):  
Yong Hong Miao ◽  
Guo Jun Cai ◽  
Song Yu Liu

Six methods to determine axial pile capacity directly based on piezocone penetration test (CPTU) data are presented and evaluated. Analyses and evaluation were conducted on three types piles that were failed during pile load testing. The CPT methods, as well as the CPTU methods, were used to estimate the load carrying capacities of the investigated piles (Qp ). Pile load test were used to determine the measured load carrying capacities (Qm). The pile capacities determined using the different methods were compared with the measured pile capacities obtained from the pile load tests. Two criteria were selected as bases of evaluation: the best fit line for Qp versus Qm and the arithmetic mean and standard deviation for the ratio Qp /Qm. Results of the analyses showed that the best methods for determining pile capacity are the CPTU methods.