scholarly journals Application of the Superposition Technique in Conduction Heat Transfer for Analysing Arrays of Shallow Boreholes in Ground Source Heat Pump Systems

Author(s):  
Carlos Naranjo-Mendoza ◽  
Muyiwa A. Oyinlola ◽  
Andrew J. Wright ◽  
Richard M. Greenough
2013 ◽  
Vol 724-725 ◽  
pp. 909-915
Author(s):  
Ping Fang Hu ◽  
Zhong Yi Yu ◽  
Fei Lei ◽  
Na Zhu ◽  
Qi Ming Sun ◽  
...  

A vertical U-tube ground heat exchanger can be utilized to exchange heat with the soil in ground source heat pump systems. The outlet temperature of the working fluid through the U-tube not only accounts for heat transfer capacity of a ground heat exchanger, but also greatly affects the operational efficiency of heat pump units, which is an important characteristic parameter of heat transfer process. It is quantified by defining a thermal effectiveness coefficient. The performance evaluation is performed with a three dimensional numerical model using a finite volume technique. A dynamic simulation was conducted to analyze the thermal effectiveness as a function of soil thermal properties, backfill material properties, separation distance between the two tube legs, borehole depth and flow velocity of the working fluid. The influence of important characteristic parameters on the heat transfer performance of vertical U-tube ground heat exchangers is investigated, which may provide the references for the design of ground source heat pump systems in practice.


2013 ◽  
Vol 76 ◽  
pp. 956-970 ◽  
Author(s):  
Luigi Schibuola ◽  
Chiara Tambani ◽  
Angelo Zarrella ◽  
Massimiliano Scarpa

2014 ◽  
Vol 945-949 ◽  
pp. 2820-2824 ◽  
Author(s):  
Li Bai ◽  
Peng Xuan Wang

For the case of ground-source heat pump in severe cold regions in winter, the heat transfer situation of the ground and ground heat exchanger was dynamically simulated according to the statistics of a project in Changchun to analysis the change of the ground heat, which provided references for the initial design and operation and management of the ground-coupled heat pump in severe cold regions.


2013 ◽  
Vol 700 ◽  
pp. 231-234
Author(s):  
Lian Yang ◽  
Yong Hong Huang ◽  
Liu Zhang

There are many ground source heat pumps in engineering construction application. However, Research on heat exchanger models of single-hole buried vertical ground source heat pump mostly focuses on single U-tube ground heat exchangers other than double U-tube ones in China currently. Compared with single U-tubes, double U-tubes have the heat transfer particularity of asymmetry. Therefore, the use of the traditional single tube models would have large error in the simulation of the actual double U-tube heat exchangers. This paper frames a three-dimensional heat transfer model for the vertical single-hole buried double u-tube heat exchanger in a ground source heat pump system. The model considers the performance of U-bube material and uses a dual coordinate system and makes the control elemental volumes superimposed.


2011 ◽  
Vol 48-49 ◽  
pp. 304-307 ◽  
Author(s):  
Xiao Bin Zhang ◽  
Wei Bing Zhu ◽  
Si Peng Tan

The heat transfer capability of the underground geothermal heat exchanger (GHE) is influenced by groundwater advection, and heat conduction and groundwater heat advection is coupled. Based on porous medium theory, the GHE’s mathematical model under coupled heat conduction and advection is established with correspond simplifications. Through numerical simulation, the performance of the GHE with groundwater advection is analyzed. The GHE’s heat transfer effect in winter in the continuous operation mode(COM) and the intermittent operation mode(IOM) is compared, furthermore the soil recovering effect in IOM is analyzed, finally the heat recovering time which the soil demands in a system running period is researched. It supplies theory support and technology accumulation for the application of ground-source heat pump (GSHP).


2012 ◽  
Vol 204-208 ◽  
pp. 4349-4355
Author(s):  
Man Fu Yan ◽  
Jiu Hai Wang

To solve the problem of enhancing the heat transfer capability of antifreeze mixture in a ground source heat pump system, the existing Transductive Support Vector Machine (TSVM) model was updated into an improved TSVM model. Also, a new method of mixed antifreeze heat transfer capability classification was given in the paper by analyzing antifreeze [1] heat transfer capability of the ground source heat pump system and applying the improved TSVM model.


2014 ◽  
Vol 889-890 ◽  
pp. 1347-1352
Author(s):  
Hong Wen Jin ◽  
Qing Shen Fang

The rock soil thermal conductivity is the most important design parameter for the ground source heat pump system. Based on the equation applied for the heat transfer between the geothermal heat exchanger and its surrounding rock soil, a quasi-three dimensional heat conduction model showing the heat transfer inside the borehole of the U-tube was established to determine the thermal conductivity of the deep-layer rock soil. The results obtained show that the average thermal conductivity got through calculation and actual determination in a tube-embedding region of the ground source heat pump engineering were 1.895 and 1.955W/(m·°C), respectively. The soil layer, which has a great thermal conductivity and a strong integrated heat transfer capability, is suitable for the use of the ground source heat pump system with the tubes embedded underground. The soil layer, with a body temperature of 19 °C and a higher initial temperature, is suitable for the heat extraction from underground in winter. The deviation between the calculation and the determination of the average thermal conductivity in the abovementioned region was 0.06, which could meet the required precision, indicating that the results from the calculation could be used for design.


Sign in / Sign up

Export Citation Format

Share Document