Propagation of three-dimensional acoustic perturbations in channels of variable cross sectional area at frequencies near the cutoff frequency

1981 ◽  
Vol 15 (6) ◽  
pp. 912-920 ◽  
Author(s):  
A. A. Osipov
2020 ◽  
Vol 0 (4) ◽  
pp. 19-24
Author(s):  
I.M. UTYASHEV ◽  
◽  
A.A. AITBAEVA ◽  
A.A. YULMUKHAMETOV ◽  
◽  
...  

The paper presents solutions to the direct and inverse problems on longitudinal vibrations of a rod with a variable cross-sectional area. The law of variation of the cross-sectional area is modeled as an exponential function of a polynomial of degree n . The method for reconstructing this function is based on representing the fundamental system of solutions of the direct problem in the form of a Maclaurin series in the variables x and λ. Examples of solutions for various section functions and various boundary conditions are given. It is shown that to recover n unknown coefficients of a polynomial, n eigenvalues are required, and the solution is dual. An unambiguous solution was obtained only for the case of elastic fixation at one of the rod’s ends. The numerical estimation of the method error was made using input data noise. It is shown that the error in finding the variable crosssectional area is less than 1% with the error in the eigenvalues of longitudinal vibrations not exceeding 0.0001.


Author(s):  
Mohammad J. Izadi

A CFD study of a 3 Dimensional flow field around two bodies (Two Canopies of a Parachutes) as two bluff bodies in an incompressible fluid (Air) is modeled here. Formations of these two bodies are top-to-top (One on the top of the other) with respect to the center of each other. One canopy with a constant cross sectional area with a vent of air at its apex, and the other with a variable cross sectional area with no vent is studied here. Vertical distances of these two bodies are varied form zero to half, equal, double and triple radius of the body with a vent on it. The flow condition is considered to be 3-D, unsteady, turbulent, and incompressible. The vertical distances between the bluff bodies, cross sectional area, and also vent ratio of bluff bodies are varied here. The drag forces with static pressures around the two bodies are calculated. From the numerical results, it can be seen that, the drag coefficient is constant on the range of zero to twenty percent of the vent ratio and it decreases for higher vent ratios for when the upper parachute is smaller than the lower one, and it increases for when the upper parachute is larger than the lower one. Both Steady and Unsteady cases gave similar results especially when the distance between the canopies is increased.


Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7764
Author(s):  
Ho-Jae Lee ◽  
Eun-A Seo ◽  
Won-Woo Kim ◽  
Jun-Mo Yang ◽  
Jae-Heum Moon

In this study, we experimentally analyzed the deformation shape of stacked layers developed using three-dimensional (3D) printing technology. The nozzle traveling speed was changed to 80, 90, 100, and 110 mm/s when printing the layers to analyze its effect on layer deformation. Furthermore, the cross-sectional area and the number of layers were analyzed by printing five layers with overall dimensions of 1000 (w) × 2200 (l) × 50 (h) mm (each layer was 10 mm high) using Vernier calipers. Moreover, we analyzed the interface and cross-sectional area of layers that are difficult to confirm visually using X-ray computed tomography (X-ray CT) analysis. As a result of measuring the deformation at the center of the layer, it was confirmed that the deformation was greater for lower nozzle traveling speeds. Consequently, the X-ray CT analysis verified that the layer had the same cross-sectional area irrespective of the layer printing order at the same nozzle travel speed, even if the layer was deformed.


Author(s):  
Mohammad J. Izadi

In this paper, a 3-D flow field around two bluff bodies in an incompressible fluid is modeled [1]. Formations of these two bodies are top to top (One on the top of the other) with respect to the center of each other. The lower on has a constant cross sectional area with a vent of air at its apex and the upper one has a variable cross sectional area with no vent on it. The vertical distances between the bluff bodies, the cross sectional area, and also the vent ratio of bluff bodies are varied here. Vertical distances of these two bodies are varied form zero to half, equal, double and triple the radius of the body with a vent on it (lower body). Flow condition is considered 3D, steady, turbulent, and incompressible. The drag force on each body and also the pressure around the two bodies are calculated. From the numerical results, it can be seen that, the drag force is constant over the range of zero to twenty percent of the vent ratios and for higher vent ratios when the upper bluff body is smaller than the lower one the drag force decreased, and it increased when the upper bluff body is larger than the lower one.


Author(s):  
Sui Lin

Freezing or melting processes, using substances with variable thermal properties, taking place in a body with variable cross-sectional area, are considered. The method of obtaining the similarity solution involves three steps, 1) transformation of the position coordinate, 2) description of the temperature field, and 3) consideration of the temperature distribution in the neighbourhood of the phase boundary. It reduces the system of equations in the neighbourhood of the phase boundary to one that is independent of the cross-sectional area. The solution of this system is a universal function and is applicable to bodies with different cross-sectional areas. A theorem for calculating the rate of propagation of the phase boundary in a body of variable cross-sectional area from that in a body of constant cross-sectional area is obtained.


Sign in / Sign up

Export Citation Format

Share Document