In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography

1995 ◽  
Vol 11 (4) ◽  
pp. 223-231 ◽  
Author(s):  
Sabee Molloi ◽  
Atila Ersahin ◽  
James Hicks ◽  
James Wallis
2021 ◽  
Vol 10 (12) ◽  
pp. 2721
Author(s):  
Nobuto Nakanishi ◽  
Shigeaki Inoue ◽  
Rie Tsutsumi ◽  
Yusuke Akimoto ◽  
Yuko Ono ◽  
...  

Ultrasound has become widely used as a means to measure the rectus femoris muscle in the acute and chronic phases of critical illness. Despite its noninvasiveness and accessibility, its accuracy highly depends on the skills of the technician. However, few ultrasound phantoms for the confirmation of its accuracy or to improve technical skills exist. In this study, the authors created a novel phantom model and used it for investigating the accuracy of measurements and for training. Study 1 investigated how various conditions affect ultrasound measurements such as thickness, cross-sectional area, and echogenicity. Study 2 investigated if the phantom can be used for the training of various health care providers in vitro and in vivo. Study 1 showed that thickness, cross-sectional area, and echogenicity were affected by probe compression strength, probe angle, phantom compression, and varying equipment. Study 2 in vitro showed that using the phantom for training improved the accuracy of the measurements taken within the phantom, and Study 2 in vivo showed the phantom training had a short-term effect on improving the measurement accuracy in a human volunteer. The new ultrasound phantom model revealed that various conditions affected ultrasound measurements, and phantom training improved the measurement accuracy.


1990 ◽  
Vol 24 (3) ◽  
pp. 219-227 ◽  
Author(s):  
Ed Vanbavel ◽  
Trudi Mooij ◽  
Maurice J.M.M. Giezeman ◽  
Jos A.E. Spaan

Radiology ◽  
2011 ◽  
Vol 259 (3) ◽  
pp. 808-815 ◽  
Author(s):  
Andrea S. Klauser ◽  
Ethan J. Halpern ◽  
Ralph Faschingbauer ◽  
Florian Guerra ◽  
Carlo Martinoli ◽  
...  

2002 ◽  
Vol 282 (5) ◽  
pp. H1697-H1702 ◽  
Author(s):  
Hui Di Wang ◽  
Douglas G. Johns ◽  
Shanqin Xu ◽  
Richard A. Cohen

Our purpose was to address the role of NAPDH oxidase-derived superoxide anion in the vascular response to ANG II. Blood pressure, aortic superoxide anion, 3-nitrotyrosine, and medial cross-sectional area were compared in wild-type mice and in mice that overexpress human superoxide dismutase (hSOD). The pressor response to ANG II was significantly less in hSOD mice. Superoxide anion levels were increased twofold in ANG II-treated wild-type mice but not in hSOD mice. 3-Nitrotyrosine increased in aortic endothelium and adventitia in wild-type but not hSOD mice. In contrast, aortic medial cross-sectional area increased 50% with ANG II in hSOD mice, comparable to wild-type mice. The lower pressor response to ANG II in the mice expressing hSOD is consistent with a pressor role of superoxide anion in wild-type mice, most likely because it reacts with nitric oxide. Despite preventing the increase in superoxide anion and 3-nitrotyrosine, the aortic hypertrophic response to ANG II in vivo was unaffected by hSOD.


2019 ◽  
Vol 22 (8) ◽  
pp. 721-728
Author(s):  
Laura H Rayhel ◽  
Jessica M Quimby ◽  
Eric M Green ◽  
Valerie J Parker ◽  
Shasha Bai

Objectives The aim of this study was to evaluate the intra- and inter-rater reliability of epaxial muscle cross-sectional area measurement on feline CT images and to determine the relationship between normalized epaxial muscle area (EMA) and subjective muscle condition score (MCS). Methods Feline transverse CT images including the junction of the 13th thoracic vertebrae/13th rib head were retrospectively reviewed. Right and left epaxial muscle circumference and vertebral body height were measured and an average normalized EMA (ratio of epaxial area:vertebral height) was calculated for each image. Measurements were performed by three individuals blinded to the clinical data and were repeated 1 month later. Intra- and inter-rater reliability of EMA was assessed with concordance correlation coefficient (CCC), and Bland–Altman analysis was performed to assess bias and limits of agreement (LoA) between and within observers at different time points. In cats for which MCS data were available, EMA was compared between differing MCSs via the Kruskal–Wallis test, with Bonferroni-corrected Wilcoxon rank-sum post-hoc analysis. Results In total, 101 CT scans met the inclusion criteria for reliability analysis, 29 of which had muscle condition information available for analysis. Intra-rater EMA CCC ranged from 0.84 to 0.99 with minimal bias (range –0.16 to 0.08) and narrow LoA. Inter-rater EMA CCC ranged from 0.87 to 0.94, bias was larger (range –0.46 to 0.66) and LoA were wider when assessed between observers. Median EMA was significantly lower in cats with severe muscle atrophy (2.76, range 1.28–3.96) than in all other MCS groups ( P <0.0001 for all comparisons). Conclusions and relevance Measurement of EMA on CT showed strong intra-rater reliability, and median EMA measurements were significantly lower in cats with severe muscle wasting, as assessed on physical examination. Further studies correlating EMA to lean muscle mass in cats are needed to determine whether this method may be useful to quantify muscle mass in patients undergoing a CT scan.


1984 ◽  
Vol 57 (5) ◽  
pp. 1399-1403 ◽  
Author(s):  
J. D. MacDougall ◽  
D. G. Sale ◽  
S. E. Alway ◽  
J. R. Sutton

Muscle fiber numbers were estimated in vivo in biceps brachii in 5 elite male bodybuilders, 7 intermediate caliber bodybuilders, and 13 age-matched controls. Mean fiber area and collagen volume density were calculated from needle biopsies and muscle cross-sectional area by computerized tomographic scanning. Contralateral measurements in a subsample of seven subjects indicated the method for estimation of fiber numbers to have adequate reliability. There was a wide interindividual range for fiber numbers in biceps (172,085–418,884), but despite large differences in muscle size both bodybuilder groups possessed the same number of muscle fibers as the group of untrained controls. Although there was a high correlation between average cross-sectional fiber area and total muscle cross-sectional area within each group, many of the subjects with the largest muscles also tended to have a large number of fibers. Since there were equally well-trained subjects with fewer than normal fiber numbers, we interpret this finding to be due to genetic endowment rather than to training-induced hyperplasia. The proportion of muscle comprised of connective and other noncontractile tissue was the same for all subjects (approximately 13%), thus indicating greater absolute amounts of connective tissue in the trained subjects. We conclude that in humans, heavy resistance training directed toward achieving maximum size in skeletal muscle does not result in an increase in fiber numbers.


Sign in / Sign up

Export Citation Format

Share Document