High-performance thin-layer chromatography of metal complexes ofmeso-tetrakis(p-tolyl)porphyrin on cellulose and silica gel

1984 ◽  
Vol 18 (8) ◽  
pp. 441-444 ◽  
Author(s):  
M. Kobayashi ◽  
K. Saitoh ◽  
N. Suzuki
INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (12) ◽  
pp. 42-48
Author(s):  
P. J. Patel ◽  
◽  
D. A Shah ◽  
F. A. Mehta ◽  
U. K. Chhalotiya

A simple, sensitive and precise high performance thin layer chromatographic (HPTLC)method has been developed for the estimation of ondansetron (OND) and ranitidine (RAN) in combination. The method was employed on thin layer chromatography (TLC) and aluminium plates were precoated with silica gel 60 F254 as the stationary phase, while the solvent system was methanol. The Rf values were observed to be 0.5 ± 0.02, and 0.3 ± 0.02 for OND and RAN, respectively. The separated spots were densitometrically analyzed in absorbance mode at 299 nm. This method was linear in the range of 25-300 ng/band for OND and 50-600 ng/band for RAN. The limits of detection for OND and RAN were found to be 3.47 and 1.83 ng/band, respectively. The limits of quantification for OND and RAN were found to be 10.53 and 5.55 ng/band, respectively. The proposed method was validated with respect to linearity, accuracy, precision and robustness. The method was successfully applied to the estimation of OND and RAN in combined dosage form.


2005 ◽  
Vol 88 (5) ◽  
pp. 1537-1543 ◽  
Author(s):  
Caitlin Sullivan ◽  
Joseph Sherma

Abstract A new quantitative method using silica gel high-performance thin-layer chromatography plates with channels and a concentration zone, manual application of standards and samples, development with methanol–ethyl acetate (15 + 85) mobile phase, and ultraviolet absorption densitometry is reported for the determination of caffeine in diuretic pharmaceutical preparations. Tablet and capsule products containing potassium salicylate, acetaminophen, and salicylamide as active ingredients were analyzed to test the applicability of the new method, and precision, accuracy, linearity, limits of detection and quantitation, and selectivity were validated. The milligrams of caffeine in each tablet ranged from 48.0 to 51.0, and the milligrams in each capsule from 37.9 to 40.3. Within-day precision was 1.48 and 1.78% (n = 6), and interday precision 0.723 and 1.26% (n = 5) for analysis of 2 tablets and 2 capsules, respectively. Accuracy validation of the tablet and capsule results produced errors of 1.0 and 1.9% for spiked blank analyses and 2.6 and 3.5% for standard addition analyses, respectively. A comparative study using a caffeine standard solution and a multicomponent analgesic tablet solution containing caffeine, acetaminophen, and acetylsalicylic acid showed that manual application on the concentration zone, instrumental application on the concentration zone, and instrumental application on the silica gel gave quite similar results in terms of number of theoretical plates, resolution, limit of detection, and linearity.


Sign in / Sign up

Export Citation Format

Share Document