The Dugdale planning method for high tibial osteotomies underestimates the correction angle compared to the Miniaci method

Author(s):  
Einar Andreas Sivertsen ◽  
Jarle Vik ◽  
Arn Ståle Vålnes Meland ◽  
Tor Kjetil Nerhus
2021 ◽  
Vol 9 (10) ◽  
pp. 232596712110341
Author(s):  
Dong Jin Ryu ◽  
Sung-Sahn Lee ◽  
Eui Yub Jung ◽  
Joo Hwan Kim ◽  
Tae Soo Shin ◽  
...  

Background: Soft tissue laxity around the knee joint has been recognized as a crucial factor affecting correction error during medial open-wedge proximal tibial osteotomy (MOWPTO). Medial laxity in particular, which represents the changes in joint-line convergence angle (JLCA), affects soft tissue correction. Purpose: The purpose of this study was to quantify medial laxity and develop a preoperative planning method that considers medial laxity. Study Design: Cohort study; Level of evidence, 3. Methods: This study retrospectively reviewed 139 knees in 117 patients who underwent navigation-assisted MOWPTO from January 2014 to July 2019 for symptomatic medial compartment osteoarthritis with varus alignment >5°. We compared the results of 2 preoperative planning methods: conventional Miniaci (n = 47) and latent medial laxity reduction (LMLR) (n = 92). We evaluated the incidence of undercorrection, acceptable correction, and overcorrection. The radiologic parameters were analyzed using multiple linear regression with a stepwise selection model to establish an equation for the optimal preoperative planning method. The intraclass correlation coefficients (ICCs) of intraobserver, interobserver, and intermethod reliability were calculated. Results: The Miniaci method showed a higher incidence of overcorrection (55.3%) than the LMLR method (22.8%) at postoperative 6 months ( P = .0006). Multiple linear regression with a stepwise selection model revealed a high correlation coefficient ( R 2 = 0.888) for the following equation: Adjusted planned correction angle = 0.596 + 0.891 × Target correction angle – 0.255 × Δ JLCA valgus. Upon simplification, the following equation showed the highest intermethod ICC value (0.991): Target correction angle – ⅓Δ JLCA valgus, while the Miniaci method showed a relatively low ICC value of 0.875. Conclusion: There was a risk of overcorrection after MOWPTO using the conventional Miniaci method. An equation that considers medial laxity may help during preoperative planning for optimal correction during MOWPTO.


CICTP 2020 ◽  
2020 ◽  
Author(s):  
Yunlin Guan ◽  
Yun Wang ◽  
Xuedong Yan ◽  
Haonan Guo ◽  
Yan Huang

2013 ◽  
Vol 133 (10) ◽  
pp. 746-752 ◽  
Author(s):  
Chihaya Murakami ◽  
Aya Fujiwara ◽  
Shinichi Iwamoto

2006 ◽  
Vol 105 (Supplement) ◽  
pp. 2-4 ◽  
Author(s):  
James G. Douglas ◽  
Robert Goodkin

ObjectIn a substantial number of patients treated at the authors' facility for brain metastases, additional lesions are identified at the time of Gamma Knife surgery (GKS). These lesions are often widely dispersed and may number over 10, which is the maximal number of matrices that can be currently placed for treatment with Leksell Gamma-Plan 4C. The authors describe a simple planning method for GKS in patients with multiple, widely dispersed central nervous system (CNS) metastases.MethodsTwo patients presented with three to five identified recurrent metastases from non–small cell lung carcinoma and breast carcinoma after having received whole-brain radiotherapy. At the time of treatment with GKS in each patient, spoiled-gradient Gd-enhanced magnetic resonance (MR) imaging revealed substantially more metastases than originally thought, which were widely scattered throughout all regions of the brain. The authors simplified the treatment planning approach by dividing the entire CNS contents into six contiguous, nonoverlapping matrices, which allowed for the planning, calculation, and treatment of all lesions.Two patients were successfully treated with GKS for more than 10 CNS metastases by using this simple planning method. Differing peripheral doses to varied-size lesions were delivered by prescribing to different isodose curves within any given matrix when required. Dose–volume histograms showed brain doses as follows: 10% of the total brain volume received 5 to 6.4 Gy; 25% received 3.8 to 4.8 Gy; 50% received 2.7 to 3.1 Gy; and 75% received 2.2 to 2.5 Gy.Conclusions The delineation of more metastases than appreciated on the diagnostic MR imaging is a common occurrence at the time of GKS at the authors' institution. The treatment of multiple (>10), widely dispersed CNS metastases can be simplified by the placement of multiple, contiguous, non-overlapping matrices, which can be employed to treat lesions in all areas of the brain when separate matrices cannot be utilized.


Sign in / Sign up

Export Citation Format

Share Document