Determination of Cu, Ni, and Zn in fuel ethanol by FAAS after enrichment in column packed with 2-aminothiazole-modified silica gel

2003 ◽  
Vol 375 (4) ◽  
pp. 574-577 ◽  
Author(s):  
P. S. Roldan ◽  
I. L. Alcântara ◽  
G. R. Castro ◽  
J. C. Rocha ◽  
C. C. F. Padilha ◽  
...  
1998 ◽  
Vol 9 (5) ◽  
pp. 494-498 ◽  
Author(s):  
Luis A. de Melo Gomes ◽  
Pedro de Magalhães Padilha ◽  
José Celso Moreira ◽  
Newton L. Dias Filho ◽  
Yoshitaka Gushikem

2008 ◽  
Vol 891 (1-3) ◽  
pp. 45-49 ◽  
Author(s):  
Xijun Chang ◽  
Haixia Luo ◽  
Yuemei Cui ◽  
Xiangbing Zhu ◽  
Yunhui Zhai ◽  
...  

2013 ◽  
Vol 800 ◽  
pp. 166-172
Author(s):  
Xiong Zhi Wu ◽  
Li Li ◽  
Fei Ping Li ◽  
Wen Ying Jin

A new sorbent (PAMAM4.0GASG) with gallic acid as functional group has been prepared based on G4.0 polyamidoamine dendrimer modified silica gel (PAMAM4.0SG) and characterized with FTIR. It was employed for selective separation, preconcentration and determination of lead in different samples by flame atomic absorption spectrometry (FAAS). Experimental conditions for effective separation and preconcentration of lead were optimized. The preconcentration factor reaches 200 for lead. The relative standard deviation (R.S.D.) under optimum conditions was 2.1% for 5.0 μg ml1 of Pb (II).The relative standard deviation (R.S.D.) was 2.1% for 5.0 μg ml1 of Pb (II). The limit of detection (LOD) of 0.081μg ml1 was achieved with a sample loading flow rate of 4.2 ml min1 and a 10 ml sample volume in the proposed method. The proposed column enrichment method was applied for the preconcentration/separation and determination of Pb (II) in tap water and river water samples successfully.


2005 ◽  
Vol 3 (2) ◽  
pp. 252-262 ◽  
Author(s):  
Mustafa Imamoglu ◽  
Ali Aydin ◽  
Mustafa Dundar

AbstractA preconcentration method of gold, palladium and copper based on the sorption of Au (III), Pd (II) and Cu (II) ions on a column packed with 3-(2-aminoethylamino)propyl bonded silica gel is described. The modified silica gel was synthesized and characterized by FT-IR and C, H, N elemental analysis. At column preconcentration, the effects of parameters such as pH, volume, flow rate, matrix constituents of solutions and type of eluent on preconcentration of gold, palladium and copper were studied. The recoveries of Au (III), Pd (II) and Cu (II) were 98.93±0.51, 98.81±0.36 and 99.21±0.42 % at 95 % confidence level, respectively. The detection limits (δ) of the elements were 0.032, 0.016 and 0.012 μg ml−1, respectively. The preconcentration method was applied for determination of gold and palladium in certified reference material SARM 7B and copper in river and synthetic seawater by FAAS. Gold, palladium and copper were determined with relative error lower than 10 %.


2004 ◽  
Vol 15 (3) ◽  
pp. 366-371 ◽  
Author(s):  
Ilton Luiz de Alcântara ◽  
Paulo dos Santos Roldan ◽  
Maurício A. L. Margionte ◽  
Gustavo R. Castro ◽  
Cilene C. F. Padilha ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document