Magnetical hollow fiber bar collection of extract in homogenous ionic liquid microextraction of triazine herbicides in water samples

2017 ◽  
Vol 409 (10) ◽  
pp. 2569-2579 ◽  
Author(s):  
Kun Wang ◽  
Jia Jiang ◽  
Mingqin Kang ◽  
Dan Li ◽  
Shuang Zang ◽  
...  
2019 ◽  
Vol 57 (10) ◽  
pp. 950-960
Author(s):  
Youyi Wu ◽  
Jingwen Zhou ◽  
Xuedong Wang ◽  
Zhanen Zhang ◽  
Shiqian Gao

Abstract Ionic liquid-based hollow-fiber liquid–liquid–liquid microextraction (IL-HF-LLLME) coupled to capillary electrophoresis (CE) has been developed for the determination of six sulfonamides (SAs) in aquaculture waters. A series of extraction parameters was optimized to enhance the extraction efficiency, which included type and pore size of hollow fiber, type and composition of extraction solvent, pH value of donor phase, the concentration of acceptor phase and the mass ratio of donor phase to acceptor phase along with extraction temperature and time. Under optimal conditions, the IL-HF-LLLME-CE method provided a wide liner range for six SAs from 2 to 1,000 μg L−1 (r2 ≥ 0.9995), the limits of the detection from 0.25 to 0.48 and the enrichment factors from 122 to 230, respectively. Relative standard deviations for intra- and interday precision were 1.4–5.3% and 1.8–7.5% (n = 5), respectively. The proposed method was successfully applied for the determination of trace-level SAs in seven real-world aquaculture water samples with good recoveries (80.4–100.7%). Also, sulfamerazine and sulfamethoxazole were detected at the level of 0.52–1.60 μg L−1 in two water samples. Due to its good sensitivity, simple operation, short analysis time and eco-friendliness, the developed method has a great application potential in analysis of trace SA residues in aquaculture waters.


2013 ◽  
Vol 675 ◽  
pp. 260-263 ◽  
Author(s):  
Du Shu Huang ◽  
Ya Shun Chen ◽  
He Ping Yan ◽  
Na Wu ◽  
Wei Liu ◽  
...  

A novel method for determination of organochlorine pesticides residuals (2,4-DDT and 4,4-DDT) in water samples through hollow fiber membrane-liquid phase microextraction using ionic liquid material as extractant coupled with high performance liquid chromatography has been developed. The effect of extraction parameters including pH of the feed solution, stirring rate and extraction time was investigated. The proposed method provided enrichment efficiency of 323 and 289 for 2,4-DDT and 4,4-DDT respectively. The method had good linear range of 0.5-50 μg /L and the limits of detection of the pesticides were 0.1 μg /L.


RSC Advances ◽  
2016 ◽  
Vol 6 (97) ◽  
pp. 95283-95291 ◽  
Author(s):  
Lu Hu ◽  
Heng Qian ◽  
Xiaoling Yang ◽  
Songqing Li ◽  
Sanbing Zhang ◽  
...  

Dispersion liquid–liquid microextraction based on the solidification of a floating ionic liquid.


Sign in / Sign up

Export Citation Format

Share Document