scholarly journals Experimental Evaluation of the Effectiveness of Aspiration-Based Techniques to Treat Different Types of Acute Thromboembolic Occlusions in the Femoropopliteal Vascular System Using an In Vitro Flow Model

Author(s):  
Schekeb Aludin ◽  
Philipp Jost Schäfer ◽  
Christoph Borzikowsky ◽  
Olav Jansen ◽  
Julian Pfarr ◽  
...  

Abstract Purpose In this in vitro study, the effectiveness and safety of four aspiration-based techniques for thrombectomy are evaluated for three types of thrombi in a flow model simulating the femoropopliteal segment. Material and Methods Red, white, and mixed thrombi were produced in a standardized manner and used to simulate occlusion of a superficial femoral artery using a pulsatile flow model. Four techniques were compared: aspiration alone, aspiration + stent retriever, exposing thrombus to laser by an excimer laser system and a laser catheter + aspiration, and aspiration + mechanical fragmentation by a separator. Rate of first-pass recanalization, embolic events, and number of embolized fragments > 1 mm were compared. Results Aspiration alone, stent retriever, laser, and separator differed in rates of first-pass recanalization (53.3%; 86.6%; 20%; and 100%) and embolic events (40%; 93.3%; 73.3%; and 60%). Number of embolized fragments was lowest with aspiration and higher with separator, laser, and stent retriever. Rates of first-pass-recanalization (75%; 75%; and 45%) and embolic events (65%; 60%; and 75%) differed for red, white, and mixed thrombi. The mixed thrombus caused the highest number of embolized fragments, which was particularly high using the stent retriever. Conclusion Additional use of mechanical techniques significantly enhances the effectiveness of thrombectomy but simultaneously provokes more embolism. Laser seems to negatively alter the structure of a thrombus and thus diminishes the effectiveness, while provoking embolism. All techniques had lowest effectiveness, but highest embolism with the mixed thrombus. This was particularly striking when a stent retriever was used with the mixed thrombus.

Polymers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1660
Author(s):  
Sevda Mihailova Yantcheva

The development of composite materials is subject to the desire to overcome polymerization shrinkage and generated polymerization stress. An indicator characterizing the properties of restorative materials, with specific importance for preventing secondary caries, is the integrity and durability of marginal sealing. It is a reflection of the effects of polymerization shrinkage and generated stress. The present study aimed to evaluate and correlate marginal integrity and micropermeability in second-class cavities restored with three different types of composites, representing different strategies to reduce polymerization shrinkage and stress: nanocomposite, silorane, and bulk-fill composite after a ten-month ageing period. Thirty standardized class ΙΙ cavities were prepared on extracted human molars. Gingival margins were 1 mm apical to the cementoenamel junction. Cavities were randomly divided into three groups, based on the composites used: FiltekUltimate-nanocomposite; Filtek Silorane LS-silorane; SonicFill-bulk-fill composite. All specimens were subjected to thermal cycles after that, dipped in saline for 10-mounds. After ageing, samples were immersed in a 2% methylene blue. Thus prepared, they were covered directly with gold and analyzed on SEM for assessment of marginal seal. When the SEM analysis was completed, the teeth were included into epoxy blocks and cut longitudinally on three slices for each cavity. An assessment of microleakage on stereomicroscope followed. Results were statistically analyzed. For marginal seal evaluation: F.Ultimate and F.Silorane differ statistically with more excellent results than SonicFill for marginal adaptation to the gingival margin, located entirely in the dentin. For microleakage evaluation: F.Ultimate and F.Silorane differ statistically with less microleakage than SonicFill. Based on the results obtained: a strong correlation is found between excellent results for marginal adaptation to the marginal gingival ridge and micropermeability at the direction to the axial wall. We observe a more significant influence of time at the gingival margin of the cavities. There is a significant increase in the presence of marginal fissures (p = 0.001). A significant impact of time (p < 0.000) and of the material (p < 0.000) was found in the analysis of the microleakage.


2002 ◽  
Vol 28 (1) ◽  
pp. 95-99 ◽  
Author(s):  
Carole Burillon ◽  
Laurent Kodjikian ◽  
Gérard Pellon ◽  
Annie Martra ◽  
Jean Freney ◽  
...  

2021 ◽  
Vol 34 (2) ◽  
pp. 254-260
Author(s):  
Alexander Schmidt ◽  
Jan-Wilhelm Billig ◽  
Maximiliane Schlenz ◽  
Bernd Wöstmann

2021 ◽  
Vol 24 (6) ◽  
pp. 828
Author(s):  
A Robaian ◽  
A Maawadh ◽  
ZI Alghomlas ◽  
AM Alqahtani ◽  
TA Alothman ◽  
...  

2012 ◽  
Vol 23 (1) ◽  
pp. 43 ◽  
Author(s):  
Priya Subramaniam ◽  
KR Maheshwar Reddy ◽  
Uma Eswara

2020 ◽  
Author(s):  
Julius J Schmidt ◽  
Gabriele Eden ◽  
Malin-Theres Seffer ◽  
Manuela Winkler ◽  
Jan T Kielstein

Abstract Background In August 2019, the European Union licensed the first ever haemoperfusion device aimed to reduce pathogens in the blood. The core of the adsorber consists of ultra-high molecular weight polyethylene beads with endpoint-attached heparin. These beads utilize pathogen inherent adhesion mechanisms to reduce pathogen load. So far, it is unknown whether the device has an effect on anti-infective drug concentrations. The aim of this study was to investigate the in vitro adsorption of multiple anti-infective drugs from human plasma. Methods In this in vitro study, 18 anti-infective drugs were administered to human donor plasma and pumped through the heparin-coated pathogen adsorber (Seraph® 100 Microbind®Affinity Blood Filter; ExThera Medical Corp., Martinez, CA, USA) at a plasma flow rate of 250 mL/min for 60 min. Pre- and post-adsorber plasma samples were quantified after 5, 15, 30 and 60 min. Results We found a reduction ratio (RR) in anti-infective plasma levels between −1% and 62%. This decrease occurred mainly in the first 5 min of the experiment (RR0–5 −4 to 62%). Mean plasma clearance rates ranged between –11.93 mL/min (fluconazole) and 4.86 mL/min (clindamycin). The highest RRs were measured for aminoglycosides (tobramycin 62% and gentamycin 59%). Conclusions The elimination of anti-infective drugs by the Seraph is neglectable in all but 2 of 18 of the investigated substances. Aminoglycosides may be adsorbed by the device during their first pass.