OBJECTIVE: To investigate the clinical value of dynamic contrast enhanced ultrasound (D-CEUS) in predicting the microvascular invasion (MVI) of hepatocellular carcinoma (HCC). PATIENTS AND METHODS: In this retrospective study, 16 patients with surgery and histopathologically proved HCC lesions were included. Patients were classified according to the presence of MVI: MVI positive group (n = 6) and MVI negative group (n = 10). Contrast enhanced ultrasound (CEUS) examinations were performed within a week before surgery. Dynamic analysis was performed by VueBox ® software (Bracco, Italy). Three regions of interests (ROIs) were set in the center of HCC lesions, at the margin of HCC lesions and in the surrounding liver parenchyma accordingly. Time intensity curves (TICs) were generated and quantitative perfusion parameters including WiR (wash-in rate), WoR (wash-out rate), WiAUC (wash-in area under the curve), WoAUC (wash-out area under the curve) and WiPi (wash-in perfusion index) were obtained and analyzed. RESULTS: All of HCC lesions showed arterial hyperenhancement (100 %) and at the late phase as hypoenhancement (75 %) in CEUS. Among all CEUS quantitative parameters, the WiAUC and WoAUC were higher in MVI positive group than in MVI negative group in the center HCC lesions (P <  0.05), WiAUC, WoAUC and WiPI were higher in MVI positive group than in MVI negative group at the margin of HCC lesions. WiR and WoR were significant higher in MVI positive group. CONCLUSIONS: D-CEUS with quantitative perfusion analysis has potential clinical value in predicting the existence of MVI in HCC lesions.


Author(s):  
Pēteris Priedītis ◽  
Maija Radziņa ◽  
Ilze Štrumfa ◽  
Zenons Narbuts ◽  
Arturs Ozoliņs ◽  
...  

Abstract The aim of the study was to investigate the diagnostic value of contrast-enhanced ultrasound (CEUS) in differentiating benign and malignant thyroid nodules. Thirty-five patients with morphologically proved thyroid nodules (17 malignant; 18 benign), underwent CEUS examination. Five enhancement patterns were evaluated: vascularisation, homogeneity, presence of peripheral rim type enhancement, wash-out rate of the contrast medium, and enhancement using microvascular imaging application. Time-intensity curves (TIC) were analysed in post-processing and defined as three types: slow versus rapid and stable versus rapid biphasic wash-out. Diagnostic value of the listed CEUS parameters was calculated. The results showed medium strength correlation between morphology (benign versus malignant nodule) and type of TIC curve rs = 0.38 (p = 0.021), as well as between mode of contrast enhancement rs = 0.39 (p = 0.022) and wash-out pattern rs =0.39 (p = 0.024). The overall pooled sensitivity of selected diagnostic parameters was 82%, specificity 57%, and accuracy 70%. Malignant nodules were characterised by iso- or hypovascular contrast enhancement and slow wash-out, while benign nodules showed hypervascular enhancement with rapid wash-out TIC curve and rim-like pattern. The CEUS patterns significantly differed between malignant and benign thyroid nodules with high diagnostic accuracy. Thus, CEUS has important clinical value as an additional tool to ultrasound and fine needle biopsy.


2016 ◽  
Vol 22 ◽  
pp. 4755-4764 ◽  
Author(s):  
Yan Zhang ◽  
Yu-kun Luo ◽  
Ming-bo Zhang ◽  
Jie Li ◽  
Junlai Li ◽  
...  

2011 ◽  
Vol 8 (2) ◽  
pp. 98-101
Author(s):  
Steven B Feinstein ◽  


2021 ◽  
Vol 11 ◽  
Author(s):  
Shi Yan Guo ◽  
Ping Zhou ◽  
Yan Zhang ◽  
Li Qing Jiang ◽  
Yong Feng Zhao

BackgroundWith the improvement of ultrasound imaging resolution and the application of various new technologies, the detection rate of thyroid nodules has increased greatly in recent years. However, there are still challenges in accurately diagnosing the nature of thyroid nodules. This study aimed to evaluate the clinical application value of the radiomics features extracted from B-mode ultrasound (B-US) images combined with contrast-enhanced ultrasound (CEUS) images in the differentiation of benign and malignant thyroid nodules by comparing the diagnostic performance of four logistic models.MethodsWe retrospectively collected and ultimately included B-US images and CEUS images of 123 nodules from 123 patients, and then extracted the corresponding radiomics features from these images respectively. Meanwhile, a senior radiologist combined the thyroid imaging reporting and data system (TI-RADS) and the enhancement pattern of the ultrasonography to make a graded diagnosis of the malignancy of these nodules. Next, based on these radiomics features and grades, logistic regression was used to help build the models (B-US radiomics model, CEUS radiomics model, B-US+CEUS radiomics model, and TI-RADS+CEUS model). Finally, the study assessed the diagnostic performance of these radiomics features with a comparison of the area under the curve (AUC) of the receiver operating characteristic curve of four logistic models for predicting the benignity or malignancy of thyroid nodules.ResultsThe AUC in the differential diagnosis of the nature of thyroid nodules was 0.791 for the B-US radiomics model, 0.766 for the CEUS radiomics model, 0.861 for the B-US+CEUS radiomics model, and 0.785 for the TI-RADS+CEUS model. Compared to the TI-RADS+CEUS model, there was no statistical significance observed in AUC between the B-US radiomics model, CEUS radiomics model, B-US+CEUS radiomics model, and TI-RADS+CEUS model (P&gt;0.05). However, a significant difference was observed between the single B-US radiomics model or CEUS radiomics model and B-US+CEUS radiomics model (P&lt;0.05).ConclusionIn our study, the B-US radiomics model, CEUS radiomics model, and B-US+CEUS radiomics model demonstrated similar performance with the TI-RADS+CEUS model of senior radiologists in diagnosing the benignity or malignancy of thyroid nodules, while the B-US+CEUS radiomics model showed better diagnostic performance than single B-US radiomics model or CEUS radiomics model. It was proved that B-US radiomics features and CEUS radiomics features are of high clinical value as the combination of the two had better diagnostic performance.


2020 ◽  
Vol 47 (1) ◽  
pp. 311-319 ◽  
Author(s):  
Zemin Li ◽  
Peili Zhang ◽  
Huiming Shen ◽  
Bo Ding ◽  
Haili Wang ◽  
...  

Gut and Liver ◽  
2016 ◽  
Vol 10 (2) ◽  
pp. 283 ◽  
Author(s):  
Wen-Tao Kong ◽  
Zheng-Biao Ji ◽  
Wen-Ping Wang ◽  
Hao Cai ◽  
Bei-Jian Huang ◽  
...  

2021 ◽  
Vol 11 (8) ◽  
pp. 2080-2085
Author(s):  
Yinfeng Hu ◽  
Xuewen Jia ◽  
Yingchun Zhu ◽  
Youfeng Xu ◽  
Minhua Guo ◽  
...  

Objectives: The aim of this study was to investigate the clinical value of Contrast-enhanced ultrasound (CEUS) in evaluating Extracorporeal shock wave therapy (ESWT) for noninfectious nonunion. Methods: Thirty-eight patients with long bone nonunion fractures whose were treated in our hospital from October 2016 to October 2019 were included (20 males and 18 females). The patients received ESWT once a week for 12 consecutive weeks. CEUS was performed before and after the first ESWT session. According to the ratio of the perfusion area to the callus area, neovascular blood flow observed in CEUS was divided into 4 grades: grade 0 = 0%, grade 1 = 0–30%, grade 2 = 30–70% and grade 3 = 70–100%. The peak values of microbubbles perfusion in the callus area were recorded before and after ESWT. Each patient was followed up for 12 months to record the healing time. Nonunion over 12 months was considered a nonhealing fracture. To compare the ultrasonic data before and after ESWT, paired T test was used and the correlation between the ultrasonic data and the nonunion healing time, the pearson analysis was used. Results: Of the 38 patients, 35 patients achieved nonunion healing. The healing time ranged from 5 months to 12 months. Among the 38 patients, 24 patients had a microvascular health score of 0 points and 14 patients had a score of 1 point before treatment. After therapy, the neovascular health score was 0, 1, 2 and 3 in 5, 10, 15 and 8 patients, respectively. There was a statistically significant difference before and after treatment (P < 0.05). The peak value of microbubbles perfusion in the fracture site after ESWT was significantly higher than that before ESWT (P < 0.05). The greater of difference, the shorter of healing time. Conclusion: Under the supervision of CEUS, the changes in microvascular perfusion of noninfectious nonunion patients before and after ESWT effectively reflected the therapeutic effect. CEUS could predict the ESWT on bone nonunion at an early stage. Level of evidence: Level III.