scholarly journals Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study

Author(s):  
D. Dammerer ◽  
A. Keiler ◽  
S. Herrnegger ◽  
D. Putzer ◽  
S. Strasser ◽  
...  

Abstract Introduction To investigate the accuracy of preoperative digital templating for total hip arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax). Materials and methods In a retrospective study design, we analysed 620 uncemented primary THAs for templating accuracy by comparing the preoperatively planned THA component size and the implanted size as documented by the surgeon. Templating was determined to be a) exact if the planned and the implanted component were the same size and b) accurate if they were exact ± one size. Moreover, we investigated factors that potentially influence templating accuracy: overweight and obesity (WHO criteria), sex, implant design, surgeon experience, preoperative diagnosis. Digital templating was done with MediCAD software. The Mann–Whitney U test and the Kruskal–Wallis test were used for statistical analysis. Results Templating was exact in 52% of stems and 51% of cups and was accurate in 90% of the stems and 85% of the cups. Regarding the factors potentially influencing templating accuracy, the type of cup implant had a significant influence (p = 0.016). Moreover, greater accuracy of stem templating was achieved in female patients (p = 0.004). No such effect was determined for the other factors investigated. Conclusions We conclude that preoperative 2D templating is accurate in 90% of the stems and 85% of the cups. Greater accuracy may be achieved in female patients. In addition to gender, the type of implant used may influence planning accuracy as well. Surgeon experience, BMI and preoperative diagnosis did not influence templating accuracy. Level of evidence Level III (retrospective comparative study with prospective cohort).

Author(s):  
Christoph Kolja Boese ◽  
Tim Rolvien ◽  
Matthias Trost ◽  
Michael Frink ◽  
Jan Hubert ◽  
...  

Abstract Objective Preoperative digital templating is a standard procedure in total hip arthroplasty. Deviations between template size and final implant size may result from inaccurate calibration, templating as well as intraoperative decisions. So far, the explicit effect of calibration errors on templating has not been addressed adequately. Materials and Methods A mathematical simulation of calibration errors up to ± 24% was applied to the templating of acetabular cups (38 to 72 mm diameter). The effect of calibration errors on template component size as deviation from optimal size was calculated. Results The relationship between calibration error and component size deviation is inverse and linear. Calibration errors have a more pronounced effect on larger component sizes. Calibration errors of 2–6% result in templating errors of up to two component sizes. Common errors of up to 12% may result in templating errors of 3–4 sizes for common implant sizes. A tabular matrix visualizes the effect. Conclusion Calibration errors play a significant role in component size selection during digital templating. Orthopedic surgeons should be aware of this effect and try to identify and address this source of error.


2013 ◽  
Vol 11 (8) ◽  
pp. 662-663
Author(s):  
Stephen McCain ◽  
Laurence Cusick ◽  
Gavan McAlinden

Sign in / Sign up

Export Citation Format

Share Document