Abstract Purpose To review functional and subjective benefit after implantation of an active transcutaneous bone conduction device (BCD) in patients with congenital microtia with atresia or stenosis of the external auditory canal. Methods Retrospective chart analysis and questionnaire on the subjective impression of hearing ( Speech, Spatial and Qualities of Hearing Scale (SSQ-B) of patients treated between 2012 and 2015. ResultsResults 18 patients (24 ears) with conductive or mixed hearing loss in unilateral (n = 10) or bilateral (n = 8) atresia were implanted with a BCD. No major complications occurred after implantation. Preoperative unaided air conduction pure tone average at 0.5, 1, 2 and 4 kHz (PTA 4 ) was 69.2 ± 11.7 dB, while postoperative aided PTA 4 was 33.4 ± 6.3 dB, resulting in a mean functional hearing gain of 35.9 +/- 15.6 dB. Preoperatively, the mean monosyllabic word recognition score was 22.9 % ± 22.3 %, which increased to 87.1 % +/- 15.1 % in the aided condition. The Oldenburger Sentence Test at S0N0 revealed a decrease in signal-to-noise-ratio from − 0.58 ± 4.40 dB in the unaided to − 5.67 ± 3.21 dB in the postoperative aided condition for all patients investigated. 15 of 18 patients had a subjective benefit showing a positive SSQ-B score (mean 1.7). Conclusion The implantation of an active bone conduction device brings along subjective and functional benefit for patients with conductive or combined hearing loss.

2020 ◽  
Vol 129 (12) ◽  
pp. 1221-1228
Author(s):  
Chunli Zhao ◽  
Jinsong Yang ◽  
Yujie Liu ◽  
Mengdie Gao ◽  
Peiwei Chen ◽  
...  

Objective: To evaluate the long-term safety and efficacy of the Clip coupler attached to the stapes head in patients with unilateral congenital aural atresia (CAA). Methods: This single-center retrospective study included 16 Mandarin-speaking patients who had unilateral microtia accompanied by CAA. All patients were divided into two groups: the short-term follow-up group (n = 9) and the long-term follow-up group (n = 7). The floating mass transducer of the Vibrant Soundbridge (VSB) was positioned in the stapes head by the Clip coupler. The safety of the VSB was investigated by comparing preoperative and postoperative bone-conduction (BC) thresholds as well as by complications. The effectiveness was evaluated by functional gain (FG), word recognition score (WRS), speech reception threshold (SRT) and signal-to-noise ratio (SNR). Results: Pre- and post-operative BC thresholds were no different in all patients. And no complications developed. VSB-aided thresholds in the free-field had improved significantly in both short- and long-term follow-up groups. The improvements of WRS were observed in two groups. The monosyllabic VSB-aided WRS in the long-term follow-up group was significantly higher than that in the short-term follow-up group. When speech was from the impaired ear and noise presented to the side of normal ear (SVSBNCL), lower SNRs were found in two groups after VSB implantation. However, there was no statistical difference in aided SNR between the two groups at SVSBNCL status. Conclusions: Our results show that the FMT connected to the stapes head is a secure and useful device for patients with unilateral CHL/MHL, not only in terms of improved hearing thresholds, but also improved speech intelligibility in quiet and noisy environments.


2015 ◽  
Vol 2015 ◽  
pp. 1-4 ◽  
Author(s):  
Giovanni Bianchin ◽  
Lorenzo Tribi ◽  
Aronne Reverzani ◽  
Patrizia Formigoni ◽  
Valeria Polizzi

We describe the novel solution adopted in positioning middle ear implant in a child with bilateral congenital aural atresia and craniofacial dysmorphism that have posed a significant challenge for the safe and correct management of deafness. A five-year-old child, affected by a rare congenital disease (Van Maldergem Syndrome), suffered from conductive hearing loss. Conventional skin-drive bone-conduction device, attached with a steel spring headband, has been applied but auditory restoration was not optimal. The decision made was to position Vibrant Soundbridge, a middle ear implant, with an original surgical application due to hypoplasia of the tympanic cavity. Intubation procedure was complicated due to child craniofacial deformities. Postoperative hearing rehabilitation involved a multidisciplinary team, showing improved social skills and language development.


2013 ◽  
Vol 24 (06) ◽  
pp. 505-513 ◽  
Author(s):  
Arjan J. Bosman ◽  
Ad F.M. Snik ◽  
Myrthe K.S. Hol ◽  
Emmanuel A.M. Mylanus

Background: The recent introduction of digital hearing aid technology for bone-conduction devices employing percutaneous stimulation may be beneficial for patients with conductive and mixed hearing loss and single sided deafness. Purpose: Performance of a recently released sound processor for bone-anchored implants, the Ponto Pro Power from Oticon Medical (bone-conduction device 2 [BCD2]), was compared with that of the Baha Intenso from Cochlear (bone-conduction device 1 [BCD1]). Research Design: Direct comparison of the subject's own device (BCD1) with the new device (BCD2) was examined in a nonrandomized design. Subjects were initially tested with BCD1. BCD2 was tested after a 4 wk acclimatization period. Study Sample: Eighteen subjects with mixed hearing loss and with at least 4 mo experience with BCD1 completed the study. Mean air-conduction and bone-conduction thresholds averaged across the frequencies of 500, 1000, 2000, and 4000 Hz were 73.9 and 34.2 dB HL, respectively. Data Collection and Analysis: Performance of the two devices was evaluated objectively by measuring aided free-field thresholds, speech perception in quiet, and speech perception in noise. A subjective evaluation was carried out with the Abbreviated Profile of Hearing Aid Benefit (APHAB) (Cox and Alexander, 1995) and the Speech, Spatial and Qualities of Hearing Scale (SSQ) questionnaire (Gatehouse and Noble, 2004). In addition, user experiences, user satisfaction, and device preference were obtained via proprietary questionnaires. Statistical significance was established with analysis-of-variance (ANOVA) and paired t-statistics with Bonferroni correction. Results: Aided free-field thresholds and speech reception thresholds (SRTs) in quiet were not statistically significantly different for either device (p > 0.05). In contrast, SRTs in noise were 2.0 dB lower (p < 0.001) for BCD2 than for BCD1. APHAB questionnaire scores on all subscales provided statistically significantly greater benefit (p < 0.05) for BCD2 than for BCD1. Also, with the SSQ most items in the speech and sound quality domain were significantly more favorable (p < 0.05) for BCD2 than for BCD1. Finally, all subjects preferred BCD2 over BCD1 with 14 subjects reporting a strong preference and four subjects an average preference for the digital signal processing provided by BCD2 over previous technology provided by BCD1.


2021 ◽  
Vol 75 (4) ◽  
pp. 1-5
Author(s):  
Joanna Marszał ◽  
Renata Gibasiewicz ◽  
Magdalena Błaszczyk ◽  
Maria Gawlowska ◽  
Wojciech Gawęcki

Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Objective: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of the Osia®, a new active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in implanted area, as well as audiological and quality of life results were analyzed six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss. Results: In all the cases, no postoperative complications were found. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2±3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90±8.2% for 50dB SPL, 98.8±2.5% for 65dB SPL and 100±0% for 80dB SPL, and mean speech understanding with Osia® in noise was 37.5%±23.6 for 50dB SPL, 93.8±4.8% for 65dB SPL and 98.8±2.5% for 80dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by the APHAB (Abbreviated Profile of Hearing Aid Benefit) and the SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required.