scholarly journals Two Bonebridge bone conduction hearing implant generations: audiological benefit and quality of hearing in children

Author(s):  
Soňa Šikolová ◽  
Milan Urík ◽  
Dagmar Hošnová ◽  
Vít Kruntorád ◽  
Michal Bartoš ◽  
...  

Abstract Purpose The study aimed to evaluate audiological benefits, quality of hearing and safety of two Bonebridge generation: BCI601 and BCI602 (MED-EL, Innsbruck, Austria) in children. Methods Twelve children were implanted: five BCI601 and seven BCI602 comprising of ten conductive hearing loss, and two single sided deaf SSD subjects. Audiological outcomes tested were sound field audiometry, functional gain, speech recognition threshold (SRT50), speech recognition in noise (SPRINT) and localisation abilities. Subjective measures were Speech, Spatial and Qualities of Hearing Scale (SSQ12). Results The mean FG with the BCI601 was 25.0 dB and with the BCI602 28.0 dB. The benefit in SRT50 was 23.2 dB and 33.8 dB, respectively. The mean benefit in SPRINT was 15% and 6.7% and the localisation ability improved from 33.3° to 16° and from 26.2° to 17.6°, respectively. The two SSD subjects reported a FG of 17 dB, a benefit in SRT50 of 22.5 and a benefit in SPRINT of 20%. Subjective outcomes improved significantly and even exceeded the values of their age-and sex matched normal hearing peers. One revision was reported: a retroauricular emphysema above the implant occurred 12 months post-OP, it was resolved operatively with the implant still being functional. Conclusion The pediatric cohort reports significant audiological benefit, even exceeding that of the age- and sex matched control. The combination of the high safety and audiological benefit makes the Bonebridge a comfortable and effective option in hearing rehabilitation in children.

2021 ◽  
Vol 75 (4) ◽  
pp. 1-5
Author(s):  
Joanna Marszał ◽  
Renata Gibasiewicz ◽  
Magdalena Błaszczyk ◽  
Maria Gawlowska ◽  
Wojciech Gawęcki

Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Objective: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of the Osia®, a new active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in implanted area, as well as audiological and quality of life results were analyzed six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss. Results: In all the cases, no postoperative complications were found. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2±3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90±8.2% for 50dB SPL, 98.8±2.5% for 65dB SPL and 100±0% for 80dB SPL, and mean speech understanding with Osia® in noise was 37.5%±23.6 for 50dB SPL, 93.8±4.8% for 65dB SPL and 98.8±2.5% for 80dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by the APHAB (Abbreviated Profile of Hearing Aid Benefit) and the SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required.


2015 ◽  
Vol 20 (4) ◽  
pp. 251-260 ◽  
Author(s):  
Gaëlle Leterme ◽  
Daniele Bernardeschi ◽  
Anissa Bensemman ◽  
Cyrille Coudert ◽  
Jean-Jacques Portal ◽  
...  

The aim of this study was to compare a contralateral routing of signal (CROS) hearing aid to a transcutaneous bone-anchored device in the same conditions. This prospective crossover study included 18 adult patients with a single-sided deafness (SSD). After a trial period of 60 days with CROS and 7 days with a transcutaneous bone-anchored device (Alpha 1®, Sophono, Boulder, Colo., USA) on a headband, 13 (72%) patients opted for Alpha 1, 2 patients for CROS, and 3 rejected both rehabilitation methods. Clinical tolerance, satisfaction, hearing performances (pure-tone audiometry, speech test in quiet and in noise, stereo audiometry, sound localization, and Hearing in Noise Test), and quality of life (Glasgow Benefit Inventory, Abbreviated Profile of Hearing Aid Benefit and Glasgow Hearing Aid Benefit questionnaires) were measured at 3 and 12 months after the implantation. Both devices improved equally the hearing in noise and the quality of life. Transcutaneous devices represent an effective option in SSD.


2010 ◽  
Vol 21 (04) ◽  
pp. 267-273 ◽  
Author(s):  
Lisa Christensen ◽  
Laura Smith-Olinde ◽  
Jillian Kimberlain ◽  
Gresham T. Richter ◽  
John L. Dornhoffer

Background: Little research exists to demonstrate efficacy and verification measures of the Baha® system versus traditional bone-conduction hearing aids. This study gives statistical data about 10 children who have used traditional bone-conduction hearing aids, Baha coupled to a Softband, and the Baha system implanted. Purpose: The purpose of this study was to compare functional gain at 500, 1000, 2000, and 4000 Hz for infants and children with bilateral conductive hearing loss who were initially fit with traditional bone-conduction devices then progressed to Baha with Softband and finally to unilateral Baha implants. Research Design: Retrospective five-year chart review. Study Sample: 10 children with bilateral conductive hearing loss due to congenital atresia and/or microtia. Participants ranged in age from 6 mo to 16 yr; three were male and seven were female. Two participants were African-American, five Caucasian, and three Hispanic. Intervention: The intervention was the Baha system used in children via a Softband or implanted as compared to traditional bone-conduction hearing aids. Data Collection and Analysis: Single-factor, repeated analyses of variance were run to examine the amount of functional gain delivered by the various devices as well as the threshold measures with each device at each frequency. Results: Participants in this study showed a statistically significant improvement when using the Baha Softband over traditional bone-conduction hearing aids. An implanted Baha has statistically as much gain as a bone-conduction transducer at all frequencies tested. Conclusions: The Baha system is a valid treatment in conductive hearing loss via a Softband or implanted. It statistically outperforms the traditional bone-conduction hearing aids and should be used as a first choice in intervention rather than a last option for inoperable conductive hearing loss.


2017 ◽  
Vol 157 (4) ◽  
pp. 565-571 ◽  
Author(s):  
Swathi Appachi ◽  
Jessica. L. Specht ◽  
Nikhila Raol ◽  
Judith E. C. Lieu ◽  
Michael S. Cohen ◽  
...  

Objective Options for management of unilateral hearing loss (UHL) in children include conventional hearing aids, bone-conduction hearing devices, contralateral routing of signal (CROS) aids, and frequency-modulating (FM) systems. The objective of this study was to systematically review the current literature to characterize auditory outcomes of hearing rehabilitation options in UHL. Data Sources PubMed, EMBASE, Medline, CINAHL, and Cochrane Library were searched from inception to January 2016. Manual searches of bibliographies were also performed. Review Methods Studies analyzing auditory outcomes of hearing amplification in children with UHL were included. Outcome measures included functional and objective auditory results. Two independent reviewers evaluated each abstract and article. Results Of the 249 articles identified, 12 met inclusion criteria. Seven articles solely focused on outcomes with bone-conduction hearing devices. Outcomes favored improved pure-tone averages, speech recognition thresholds, and sound localization in implanted patients. Five studies focused on FM systems, conventional hearing aids, or CROS hearing aids. Limited data are available but suggest a trend toward improvement in speech perception with hearing aids. FM systems were shown to have the most benefit for speech recognition in noise. Studies evaluating CROS hearing aids demonstrated variable outcomes. Conclusions Data evaluating functional and objective auditory measures following hearing amplification in children with UHL are limited. Most studies do suggest improvement in speech perception, speech recognition in noise, and sound localization with a hearing rehabilitation device.


2005 ◽  
Vol 16 (09) ◽  
pp. 726-739 ◽  
Author(s):  
Rachel A. McArdle ◽  
Richard H. Wilson ◽  
Christopher A. Burks

The purpose of this mixed model design was to examine recognition performance differences when measuring speech recognition in multitalker babble on listeners with normal hearing (n = 36) and listeners with hearing loss (n = 72) utilizing stimulus of varying linguistic complexity (digits, words, and sentence materials). All listeners were administered two trials of two lists of each material in a descending speech-to-babble ratio. For each of the materials, recognition performances by the listeners with normal hearing were significantly better than the performances by the listeners with hearing loss. The mean separation between groups at the 50% point in signal-to-babble ratio on each of the three materials was ~8 dB. The 50% points for digits were obtained at a significantly lower signal-to-babble ratio than for sentences or words that were equivalent. There were no interlist differences between the two lists for the digits and words, but there was a significant disparity between QuickSIN™ lists for the listeners with hearing loss. A two-item questionnaire was used to obtain a subjective measurement of speech recognition, which showed moderate correlations with objective measures of speech recognition in noise using digits (r = .641), sentences (r = .572), and words (r = .673).


2021 ◽  
pp. 019459982110045
Author(s):  
Alana Aylward ◽  
Morganne Murphy-Meyers ◽  
Chelsea McCarty Allen ◽  
Neil S. Patel ◽  
Richard K. Gurgel

Objective To examine the relationship among frailty index, hearing measures, and hearing-related quality of life (QOL) in older recipients of cochlear implants. Study Design Cross-sectional survey. Setting Academic medical center. Methods Adults aged ≥65 years at the time of receiving cochlear implants between July 13, 2000, and April 3, 2019, were asked to complete a questionnaire on hearing-related QOL. Chart review was performed to identify patients’ characteristics. Correlations were calculated between frailty index and audiologic outcome measures as well as between speech recognition scores and QOL scores. Linear regression models were developed to examine the impact of clinical characteristics, frailty index, and hearing measures on hearing-related QOL. Results Data for 143 respondents were included. The mean age was 80.7 years (SD, 7.1), with a mean 27.8 years of hearing loss (SD, 17.4) before implantation. The mean frailty index was 11.1 (SD, 10.6), indicating that patients had 1 or 2 of the measured comorbidities on average. No correlation was found between lower frailty index (better health) and hearing scores, including pure tone averages (PTAs) and speech recognition scores. Lower frailty index and larger improvement in PTA after cochlear implantation predicted better QOL scores on univariate analysis (respectively, P = .002, β = −0.42 [95% CI, −0.68 to −0.16]; P = .008, β = −0.15 [95% CI, −0.26 to −0.04]) and multivariate analysis ( P = .047, β = −0.28 [95% CI, −0.55 to −0.01]; P = .006, β = −0.16 [95% CI, −0.28 to −0.05]). No speech recognition scores correlated with QOL after cochlear implantation. Conclusions Frailty index does not correlate with hearing scores after cochlear implantation in older adults. Lower frailty index and more improvement in PTA predict better QOL scores after cochlear implantation in older adults.


2021 ◽  
Vol 4 (2) ◽  
pp. 45-50
Author(s):  
Ecem KARTAL ÖZCAN ◽  
Merve ÖZBAL BATUK ◽  
Şule KAYA ◽  
Gonca SENNAROĞLU

Assessment of speech perception in noise in children with hearing aids: Preliminary results* Objective: Noisy environments are a part of the daily life of children, just like adults. Children with hearing loss who wear hearing aids are more susceptible to the negative effects of noise than their normal-hearing peers. This study aims to evaluate the speech recognition in noise performance of hearing aid users and compare them with their normal-hearing peers. Material and Method: Five children aged 6-12 years with bilateral moderate to severe symmetrical sensorineural hearing loss and using bilateral behind-the-ear hearing aids were included in the study. 4 different conditions of the Turkish HINT-C were applied, and a speech recognition threshold (SRT) is determined for each condition. Results: Regardless of their age, the SRT needed by children with hearing aids to achieve equal performance with their normal-hearing peers was found to be higher for all test conditions. As seen in children with normal hearing in general, the mean noise front score of the children with hearing loss was higher than the mean noise right and noise left scores. Conclusion: The results of this study revealed that children with bilaterally symmetrical moderate to severe hearing loss achieved poor speech recognition scores in environments similar to the classroom environment, compared to their normal-hearing peers. Our results guided appropriate rehabilitation and follow-up. Keywords: noise, speech recognition in noise, hearing loss, hearing aid, pediatric audiology, HINT, HINT-C


2021 ◽  
pp. 019459982110620
Author(s):  
Alexander L. Luryi ◽  
Amy Schettino ◽  
Elias M. Michaelides ◽  
Seilesh Babu ◽  
Dennis I. Bojrab ◽  
...  

Objective Stapes surgery for otosclerosis occasionally requires revision due to recurrent or persistent conductive hearing loss (CHL). This study examines outcomes after revision stapes surgery. Study Design Retrospective review. Setting Single tertiary neurotology center. Methods Patients undergoing revision stapes surgery for otosclerosis from 2008 to 2017 were reviewed. Postoperative air-bone gaps (ABGs) were the primary outcome measure. Results During the study period, 150 patients underwent revision stapes surgery. One hundred patients (67%) had gradually progressive recurrent CHL; 16 (11%), sudden recurrent CHL; 13 (9%), persistent CHL; and 21 (14%), no CHL. For 129 patients with CHL, the mean ABG improved from 23.7 to 9.3 dB ( P < .0005). The most common intraoperative findings for these patients were prosthesis displacement with incus necrosis (38%) or without it (43%), normal anatomy with seemingly good prosthesis placement (6%), and abundant scar tissue (6%). Patients with recurrent hearing loss achieved lower mean ABGs than patients with persistent hearing loss (8.8 vs 13.2 dB, P = .02). There were no associations between onset pattern of CHL or intraoperative findings and hearing outcomes ( P > .05). Four patients (2.7%) developed sensorineural hearing loss after revision, defined as an increase in bone conduction pure tone average ≥15 dB, all of whom had previous replacement of a malpositioned prosthesis. Conclusions Revision stapes surgery confers significant improvement in hearing for patients with persistent and recurrent CHL, although patients with persistent CHL after initial surgery see less improvement with revision.


2016 ◽  
Vol 20 ◽  
pp. 233121651666933 ◽  
Author(s):  
Friedrich Ihler ◽  
Jenny Blum ◽  
Max-Ulrich Berger ◽  
Bernhard G. Weiss ◽  
Christian Welz ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document