Influence of bone density and implant drill diameter on the resulting axial force and temperature development in implant burs and artificial bone: an in vitro study

2015 ◽  
Vol 20 (2) ◽  
pp. 135-142 ◽  
Author(s):  
Stephan Christian Möhlhenrich ◽  
Mustapha Abouridouane ◽  
Nicole Heussen ◽  
Ali Modabber ◽  
Fritz Klocke ◽  
...  
Author(s):  
Oscar Salomó-Coll ◽  
Beatriz Auriol-Muerza ◽  
Naroa Lozano-Carrascal ◽  
Federico Hernández-Alfaro ◽  
Hom-Lay Wang ◽  
...  

2019 ◽  
Vol 17 (3) ◽  
pp. 446-450 ◽  
Author(s):  
I. Gusti Aju Wahju Ardani ◽  
Rachman Indharmawan ◽  
Thalca Hamid

2021 ◽  
Vol 36 (2) ◽  
pp. 322-326
Author(s):  
Georgios Romanos ◽  
Jessica Lau ◽  
Yun Zhang ◽  
Wei Hou ◽  
Rafael Delgado-Ruiz

2003 ◽  
Vol 254-256 ◽  
pp. 1067-1070
Author(s):  
Kazuhide Miyazaki ◽  
Takafumi Yoshikawa ◽  
Koji Hattori ◽  
Noriko Okumura ◽  
Jin Iida ◽  
...  

2015 ◽  
Vol 39 (4) ◽  
pp. 761-768 ◽  
Author(s):  
Tim Pohlemann ◽  
Boyko Gueorguiev ◽  
Yash Agarwal ◽  
Dieter Wahl ◽  
Christoph Sprecher ◽  
...  

1994 ◽  
Vol 9 (3) ◽  
pp. 175-179 ◽  
Author(s):  
S.J. Edmondston ◽  
K.P. Singer ◽  
R.E. Day ◽  
P.D. Breidahl ◽  
R.I. Price

2013 ◽  
Vol 17 ◽  
pp. e35-e44 ◽  
Author(s):  
Giovanna Iezzi ◽  
Antonio Scarano ◽  
Danilo Di Stefano ◽  
Paolo Arosio ◽  
Kazuya Doi ◽  
...  

2020 ◽  
Vol 8 (4) ◽  
pp. 138
Author(s):  
Alessandra Marchi ◽  
Matteo Camporesi ◽  
Maurizio Festa ◽  
Luis Salvatierra ◽  
Sara Izadi ◽  
...  

The aims of this study were to assess the values and mechanical properties of insertion torque (IT) of steel miniscrews inserted in artificial bone blocks (Sawbones, Pacific Research Laboratories, Vashon, WA, USA) with different bone densities and to detect any scratches on the surface of the miniscrews after insertion. Forty self-drilling miniscrews (Leone S.p.A. ø 1.75 mm, L 8 mm) have been inserted into bone blocks that mimic different stability conditions (density: 20 PCF—pounds per cubic foot, 40 PCF, and 30 + 50 PCF with 2 mm and 4 mm of cortical bone). Before insertion and after removal, all miniscrews were inspected with a stereomicroscope 5x and a SEM to detect potential microscopic cracks. Using an electronic surgical motor (W&H Dentalwerk Bürmoos GmbH, Werner Bader Str. 1, 5111 Bürmoos, Austria), the maximum insertion torque value was registered. Stereomicroscope and SEM examination did not indicate any morphological and surface structural changes to the miniscrews, irrespective of the bone density they were inserted into. The findings showed that IT increased significantly with increasing bone density. In each artificial bone block, morphostructural analysis demonstrated the adequate mechanical properties of the self-drilling miniscrews. IT measurements indicated torque values between 6 and 10 Ncm for blocks with a density of 30 + 50 PCF, whereas the suggested values are between 5 and 10 Ncm.


Sign in / Sign up

Export Citation Format

Share Document