scholarly journals Personalized Dosimetry for Liver Cancer Y-90 Radioembolization Using Computational Fluid Dynamics and Monte Carlo Simulation

2020 ◽  
Vol 48 (5) ◽  
pp. 1499-1510 ◽  
Author(s):  
Emilie Roncali ◽  
Amirtahà Taebi ◽  
Cameron Foster ◽  
Catherine Tram Vu
2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Amirtahà Taebi ◽  
Catherine T. Vu ◽  
Emilie Roncali

Abstract Yttrium-90 (90Y) radioembolization is a minimally invasive procedure increasingly used for advanced liver cancer treatment. In this method, radioactive microspheres are injected into the hepatic arterial bloodstream to target, irradiate, and kill cancer cells. Accurate and precise treatment planning can lead to more efficient and safer treatment by delivering a higher radiation dose to the tumor while minimizing the exposure of the surrounding liver parenchyma. Treatment planning primarily relies on the estimated radiation dose delivered to tissue. However, current methods used to estimate the dose are based on simplified assumptions that make the dosimetry results unreliable. In this work, we present a computational model to predict the radiation dose from the 90Y activity in different liver segments to provide a more realistic and personalized dosimetry. Computational fluid dynamics (CFD) simulations were performed in a 3D hepatic arterial tree model segmented from cone-beam CT angiographic data obtained from a patient with hepatocellular carcinoma (HCC). The microsphere trajectories were predicted from the velocity field. 90Y dose distribution was then calculated from the volumetric distribution of the microspheres. Two injection locations were considered for the microsphere administration, a lobar and a selective injection. Results showed that 22% and 82% of the microspheres were delivered to the tumor, after each injection, respectively, and the combination of both injections ultimately delivered 49% of the total administered 90Y microspheres to the tumor. Results also illustrated the nonhomogeneous distribution of microspheres between liver segments, indicating the importance of developing patient-specific dosimetry methods for effective radioembolization treatment.


2020 ◽  
Vol 148 ◽  
pp. 107718
Author(s):  
Tiago Augusto Santiago Vieira ◽  
Graiciany P. Barros ◽  
Daniel Campolina ◽  
Vitor Vasconcelos ◽  
André A. Campagnole dos Santos

Author(s):  
Ahmed Khalil ◽  
Domenico Santoro ◽  
Damien J. Batstone ◽  
Christopher T. DeGroot

Abstract Modelling conversion processes in sewers can help minimize odour and pipe corrosion issues, but model uncertainties and errors must be understood. In this study, the Wastewater Aerobic/Anaerobic Transformation in Sewers (WATS) model is implemented in two different frameworks; 1-D (CSTR-in-series) and computational fluid dynamics (CFD) to study the uncertainties due to model parameters and its mathematical form. The 1-D model is used to conduct uncertainty/sensitivity analysis using Monte Carlo simulations. Time-averaged outputs were represented using a general linearized model to quantify the importance of specific parameters. The sulfide formation rate per unit area of the biofilm is the most influential parameter. Parameters controlling anaerobic hydrolysis and fermentation are also significant. Uncertainty due to model structure is studied using CFD to explore the influences of non-homogeneous surface reactions and solids settling. These showed that the 1-D model provides a reasonable characterisation of the process for simple flows in pressure mains.


Sign in / Sign up

Export Citation Format

Share Document