scholarly journals Newborn screening for mucopolysaccharidoses: a pilot study of measurement of glycosaminoglycans by tandem mass spectrometry

2016 ◽  
Vol 40 (1) ◽  
pp. 151-158 ◽  
Author(s):  
Francyne Kubaski ◽  
Robert W. Mason ◽  
Akiko Nakatomi ◽  
Haruo Shintaku ◽  
Li Xie ◽  
...  
2016 ◽  
Vol 23 (3) ◽  
pp. 124-129 ◽  
Author(s):  
Fayza A Hassan ◽  
Fatma El-Mougy ◽  
Sahar A Sharaf ◽  
Iman Mandour ◽  
Marian F Morgan ◽  
...  

2020 ◽  
Vol 6 (4) ◽  
pp. 81
Author(s):  
Patricia L. Hall ◽  
Hong Li ◽  
Arthur F. Hagar ◽  
S. Caleb Jerris ◽  
Angela Wittenauer ◽  
...  

We screened 51,081 newborns for X-linked adrenoleukodystrophy (ALD) using a two-tiered strategy quantifying very long chain lysophosphatadylcholines (LPC). Our testing strategy used flow injection tandem mass spectrometry for the first-tier analysis of LPCs, and second-tier quantification of C26:0 LPC using liquid chromatography tandem mass spectrometry. There were 364 specimens considered abnormal using our first-tier algorithm that relied on the four LPC measurements and post-analytical tools. Second-tier test results were reported as normal or abnormal based on a cutoff for the single analyte, C26:0 LPC. Eleven cases were reported as abnormal based on second-tier test results. One male with ALD was identified, and two females with peroxisomal biogenesis disorders were also identified. A single female case remains unresolved, due to a loss to follow up after a negative molecular test result for ABCD1 gene sequencing. The positive predictive value for confirmed, clinically relevant disorders during this pilot study was 27.3%. Challenges identified during the study period were based around coverage for confirmatory testing, particularly if family members needed molecular testing, which is an ongoing issue with newborn screening in Georgia. We also encountered issues with the follow up for a patient who remained asymptomatic. Due to the different timelines involved with clinical findings in ALD, follow-up coordination may be more difficult, particularly if the child identified by newborn screening (NBS) is the only member of the family affected, or able to be tested.


2016 ◽  
Vol 118 (4) ◽  
pp. 304-309 ◽  
Author(s):  
Susan Elliott ◽  
Norman Buroker ◽  
Jason J. Cournoyer ◽  
Anna M. Potier ◽  
Joseph D. Trometer ◽  
...  

2017 ◽  
Vol 120 (1-2) ◽  
pp. S78
Author(s):  
Francyne Kubaski ◽  
Robert W Mason ◽  
Akiko Nakatomi ◽  
Haruo Shintaku ◽  
Haruo Shintaku ◽  
...  

Author(s):  
Yiming Lin ◽  
Weifeng Zhang ◽  
Zhixu Chen ◽  
Chunmei Lin ◽  
Weihua Lin ◽  
...  

Abstract Objectives Multiple acyl-CoA dehydrogenase deficiency (MADD) is an autosomal recessive disorder of fatty acid, amino acid and choline metabolism. Late-onset MADD is caused by ETFDH mutations and is the most common lipid storage myopathy in China. However, few patients with MADD have been identified through newborn screening (NBS). This study assessed the acylcarnitine profiles and molecular features of patients with MADD identified through NBS. Methods From January 2014 to June 2020, 479,786 newborns screened via tandem mass spectrometry were recruited for this study. Newborns with elevated levels of multiple acylcarnitines were recalled, those who tested positive in the reassessment were referred for genetic analysis. Results Of 479,786 newborns screened, six were diagnosed with MADD. The MADD incidence in the Chinese population was estimated to be 1:79,964. Initial NBS revealed five patients with typical elevations in the levels of multiple acylcarnitines; however, in one patient, acylcarnitine levels were in the normal reference range during recall. Notably, one patient only exhibited a mildly increased isovalerylcarnitine (C5) level at NBS. The patient with an atypical acylcarnitine profile was diagnosed with MADD by targeted gene sequencing. Six distinct ETFDH missense variants were identified, with the most common variant being c.250G>A (p.A84T), with an allelic frequency of 58.35 (7/12). Conclusions These findings revealed that it is easy for patients with MADD to go unidentified, as they may have atypical acylcarnitine profiles at NBS and the recall stage, indicating the value of genetic analysis for confirming suspected inherited metabolic disorders in the NBS program. Therefore, false-negative (FN) results may be reduced by combining tandem mass spectrometry (MS/MS) with genetic testing in NBS for MADD.


2017 ◽  
Vol 12 ◽  
pp. 80-81 ◽  
Author(s):  
Michael H. Gelb ◽  
C. Ronald Scott ◽  
Frantisek Turecek ◽  
Hsuan-Chieh Liao

2019 ◽  
Vol 205 ◽  
pp. 176-182 ◽  
Author(s):  
Min-Ju Chan ◽  
Hsuan-Chieh Liao ◽  
Michael H. Gelb ◽  
Chih-Kuang Chuang ◽  
Mei-Ying Liu ◽  
...  

2014 ◽  
Vol 88 ◽  
pp. 201-206 ◽  
Author(s):  
Giancarlo la Marca ◽  
Elisa Giocaliere ◽  
Sabrina Malvagia ◽  
Silvia Funghini ◽  
Daniela Ombrone ◽  
...  

2021 ◽  
Vol 8 ◽  
Author(s):  
Yanyun Wang ◽  
Yun Sun ◽  
Tao Jiang

Background: Tandem mass spectrometry becomes a common and important test in newborn screening, but potential contamination of the equipment has largely been ignored.Methods: The source of contamination through Biosan quality control samples was examined prospectively, and further confirmed by retrospective analysis of patient samples.Results: We found that the source of contamination came from a syringe in the Biosan quality control samples. Furthermore, we found that a large number of indicators in the patient sample were interfered by syringe contamination in our center, and also in two other newborn screening centers, but the affected indicators were different in different screening centers.Conclusion: Syringe contamination will affect the detection of patient samples by tandem mass spectrometry and should be monitored carefully and immediately.


Sign in / Sign up

Export Citation Format

Share Document