High-definition computed tomography for coronary artery stents: image quality and radiation doses for low voltage (100 kVp) and standard voltage (120 kVp) ECG-triggered scanning

2015 ◽  
Vol 31 (S1) ◽  
pp. 39-49 ◽  
Author(s):  
Ji Won Lee ◽  
Chang Won Kim ◽  
Han Cheol Lee ◽  
Ming-Ting Wu ◽  
Lee Hwangbo ◽  
...  
2019 ◽  
Vol 15 (4) ◽  
pp. 304-315 ◽  
Author(s):  
Caryl E. Richards ◽  
Daniel R. Obaid

Background: Coronary computed tomography angiography (CCTA) is now widely used in the diagnosis of coronary artery disease since it is a rapid, minimally invasive test with a diagnostic accuracy comparable to coronary angiography. However, to meet demands for increasing spatial and temporal resolution, higher x-ray radiation doses are required to circumvent the resulting increase in image noise. Exposure to high doses of ionizing radiation with CT imaging is a major health concern due to the potential risk of radiation-associated malignancy. Given its increasing use, a number of dose saving algorithms have been implemented to CCTA to minimize radiation exposure to “as low as reasonably achievable (ALARA)” without compromising diagnostic image quality. Objective: The purpose of this review is to outline the most recent advances and current status of dose saving techniques in CCTA. Methods: PubMed, Medline, EMBASE and Scholar databases were searched to identify feasibility studies, clinical trials, and technology guidelines on the technical advances in CT scanner hardware and reconstruction software. Results: Sub-millisievert (mSv) radiation doses have been reported for CCTA due to a combination of strategies such as prospective electrocardiogram-gating, high-pitch helical acquisition, tube current modulation, tube voltage reduction, heart rate reduction, and the most recent novel adaptive iterative reconstruction algorithms. Conclusion: Advances in radiation dose reduction without loss of image quality justify the use of CCTA as a non-invasive alternative to coronary catheterization in the diagnosis of coronary artery disease.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Richard G. Kavanagh ◽  
John O’Grady ◽  
Brian W. Carey ◽  
Patrick D. McLaughlin ◽  
Siobhan B. O’Neill ◽  
...  

Magnetic resonance imaging (MRI) is the mainstay method for the radiological imaging of the small bowel in patients with inflammatory bowel disease without the use of ionizing radiation. There are circumstances where imaging using ionizing radiation is required, particularly in the acute setting. This usually takes the form of computed tomography (CT). There has been a significant increase in the utilization of computed tomography (CT) for patients with Crohn’s disease as patients are frequently diagnosed at a relatively young age and require repeated imaging. Between seven and eleven percent of patients with IBD are exposed to high cumulative effective radiation doses (CEDs) (>35–75 mSv), mostly patients with Crohn’s disease (Newnham E 2007, Levi Z 2009, Hou JK 2014, Estay C 2015). This is primarily due to the more widespread and repeated use of CT, which accounts for 77% of radiation dose exposure amongst patients with Crohn’s disease (Desmond et al., 2008). Reports of the projected cancer risks from the increasing CT use (Berrington et al., 2007) have led to increased patient awareness regarding the potential health risks from ionizing radiation (Coakley et al., 2011). Our responsibilities as physicians caring for these patients include education regarding radiation risk and, when an investigation that utilizes ionizing radiation is required, to keep radiation doses as low as reasonably achievable: the “ALARA” principle. Recent advances in CT technology have facilitated substantial radiation dose reductions in many clinical settings, and several studies have demonstrated significantly decreased radiation doses in Crohn’s disease patients while maintaining diagnostic image quality. However, there is a balance to be struck between reducing radiation exposure and maintaining satisfactory image quality; if radiation dose is reduced excessively, the resulting CT images can be of poor quality and may be nondiagnostic. In this paper, we summarize the available evidence related to imaging of Crohn’s disease, radiation exposure, and risk, and we report recent advances in low-dose CT technology that have particular relevance.


2016 ◽  
Vol 25 (4) ◽  
pp. 230-234
Author(s):  
Wai-Yung Yu ◽  
Thye Sin Ho ◽  
Henry Ko ◽  
Wai-Yee Chan ◽  
Serene Ong ◽  
...  

Introduction: The use of computed tomography (CT) imaging as a diagnostic modality is increasing rapidly and CT is the dominant contributor to diagnostic medical radiation exposure. The aim of this project was to reduce the effective radiation dose to patients undergoing cranial CT examination, while maintaining diagnostic image quality. Methods: Data from a total of 1003, 132 and 27 patients were examined for three protocols: CT head, CT angiography (CTA), and CT perfusion (CTP), respectively. Following installation of adaptive iterative dose reduction (AIDR) 3D software, tube current was lowered in consecutive cycles, in a stepwise manner and effective radiation doses measured at each step. Results: Baseline effective radiation doses for CT head, CTA and CTP were 1.80, 3.60 and 3.96 mSv, at currents of 300, 280 and 130–150 mA, respectively. Using AIDR 3D and final reduced currents of 160, 190 and 70–100 mA for CT head, CTA and CTP gave effective doses of 1.29, 3.18 and 2.76 mSv, respectively. Conclusion: We demonstrated that satisfactory reductions in the effective radiation dose for CT head (28.3%), CTA (11.6%) and CTP (30.1%) can be achieved without sacrificing diagnostic image quality. We have also shown that iterative reconstruction techniques such as AIDR 3D can be effectively used to help reduce effective radiation dose. The dose reductions were performed within a short period and can be easily achievable, even in busy departments.


2012 ◽  
Vol 2012 ◽  
pp. 1-10 ◽  
Author(s):  
Diego Coelho Lorenzoni ◽  
Ana Maria Bolognese ◽  
Daniela Gamba Garib ◽  
Fabio Ribeiro Guedes ◽  
Eduardo Franzotti Sant’Anna

Introduction. The aim of this study was to discuss the radiation doses associated with plain radiographs, cone-beam computed tomography (CBCT), and conventional computed tomography (CT) in dentistry, with a special focus on orthodontics.Methods. A systematic search for articles was realized by MEDLINE from 1997–March 2011.Results. Twenty-seven articles met the established criteria. The data of these papers were grouped in a table and discussed.Conclusions. Increases in kV, mA, exposure time, and field of view (FOV) increase the radiation dose. The dose for CT is greater than other modalities. When the full-mouth series (FMX) is performed with round collimation, the orthodontic radiographs transmit higher dose than most of the large FOV CBCT, but it can be reduced if used rectangular collimation, showing lower effective dose than large FOV CBCT. Despite the image quality, the CBCT does not replace the FMX. In addition to the radiation dose, image quality and diagnostic needs should be strongly taken into account.


2017 ◽  
Vol 59 (9) ◽  
pp. 1066-1073 ◽  
Author(s):  
Anne Günther ◽  
Lars Aaberge ◽  
Andreas Abildgaard ◽  
Asgrimur Ragnarsson ◽  
Thor Edvardsen ◽  
...  

Background Cardiac allograft vasculopathy (CAV) is an accelerated form of atherosclerosis unique to heart transplant (HTX) patients. Purpose To investigate the detection of significant coronary artery stenosis and CAV, determinants of image quality, and the radiation dose in coronary computed tomography angiography (CCTA) of HTX patients with 64-slice multidetector CT (64-MDCT). Material and Methods Fifty-two HTX recipients scheduled for invasive coronary angiography (ICA) were prospectively enrolled and underwent CCTA before ICA with intravascular ultrasound (IVUS). Results Interpretable CCTA images were acquired in 570 (95%) coronary artery segments ≥2 mm in diameter. Sensitivity, specificity, and positive and negative predictive values of CCTA for the detection of segments with significant stenosis (lumen reduction ≥50%) on ICA were 100%, 98%, 7.7%, and 100%, respectively. Twelve significant stenoses were located in segments with uninterpretable image quality or vessel diameter <2 mm; only one was eligible for intervention. IVUS detected CAV (maximal intimal thickness ≥0.5 mm) in 33/41 (81%) patients; CCTA and ICA identified CAV (any wall or luminal irregularity) in 18 (44%) and 14 (34%) of these 33 patients, respectively. The mean estimated radiation dose was 19.0 ± 3.4 mSv for CCTA and 5.7 ± 3.3 mSv for ICA ( P < 0.001). Conclusion CCTA with interpretable image quality had a high negative predictive value for ruling out significant stenoses suitable for intervention. The modest detection of CAV by CCTA implied a limited value in identifying subtle CAV. The high estimated radiation dose for 64-MDCT is of concern considering the need for repetitive examinations in the HTX population.