radiation dose exposure
Recently Published Documents


TOTAL DOCUMENTS

48
(FIVE YEARS 14)

H-INDEX

9
(FIVE YEARS 1)

2021 ◽  
Vol 16 (12) ◽  
pp. 30-37
Author(s):  
Pooja Shivappa ◽  
Prashanth Shetty ◽  
N. Suchetha Kumari ◽  
K. Shetty Jayaram ◽  
K.P. Sharmila

Radiotherapy potentially offers protection from recurrence of tumor that also causes normal tissue damage and creates major concern. Another important factor is long-term immune suppression in patients treated with radiotherapy. Therefore, crucial need for the survival of surrounding normal cells of tumor by radiation‑protecting agents is the prime focus of this study. Aqueous extract (AE) and ethanolic extract (EE), Tanacetum parthenium extracts100 mg/kg each and parthenolide (PAR) 4mg/kg body weight were orally administered prior to sub-lethal radiation dose exposure. Mice were used for the evaluation of radiation-mediated chromosomal aberrations in bone marrow cells and DNA break by comet assay in the blood lymphocytes of mice. The pro-inflammatory levels were determined by cytokine estimations namely interleukin‑2, interferongamma and tumor necrosis factor-alpha performed in the liver homogenate using ELISA kits. Thus the results demonstrated ameliorating, radio-mitigating and immune-stimulatory efficacy of AE, EE and PAR against radiation ‑induced DNA damage and immunosuppression by regulating cytokine.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Bow Wang ◽  
Chien-Yi Ting ◽  
Cheng-Shih Lai ◽  
Yi-Shan Tsai

Background. Radiation using conventional X-ray is associated with exposure of radiosensitive organs and typically requires the use of protection. This study is aimed at evaluating the use of bismuth shielding for radiation protection in pediatric pelvic radiography. The effects of the anteroposterior and lateral bismuth shielding were verified by direct measurements at the anatomical position of the gonads. Methods. Radiation doses were measured using optically stimulated luminescence dosimeters (OSLD) and CIRS ATOM Dosimetry Verification Phantoms. Gonad radiographs were acquired using different shields of varying material (lead, bismuth) and thickness and were compared with radiographs obtained without shielding to examine the effects on image quality and optimal reduction of radiation dose. All images were evaluated separately by three pediatric orthopedic practitioners. Results. Results showed that conventional lead gonadal shielding reduces radiation doses by 67.45%, whereas dose reduction using one layer of bismuth shielding is 76.38%. The use of two layers of bismuth shielding reduces the dose by 84.01%. Using three and four layers of bismuth shielding reduces dose by 97.33% and 99.34%, respectively. Progressively lower radiation doses can be achieved by increasing the number of bismuth layers. Images obtained using both one and two layers of bismuth shielding provided adequate diagnostic information, but those obtained using three or four layers of bismuth shielding were inadequate for diagnosis. Conclusions. Bismuth shielding reduces radiation dose exposure providing appropriate protection for children undergoing pelvic radiography. The bismuth shielding material is lighter than lead, making pediatric patients more comfortable and less apt to move, thereby avoiding repeat radiography.


Radiology ◽  
2021 ◽  
pp. 210245
Author(s):  
Thomas J. Stocker ◽  
Jonathon Leipsic ◽  
Marcus Y. Chen ◽  
Stephan Achenbach ◽  
Juhani Knuuti ◽  
...  

Radiation ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 153-161
Author(s):  
Massimo Cristofaro ◽  
Nicoletta Fusco ◽  
Ada Petrone ◽  
Fabrizio Albarello ◽  
Federica Di Stefano ◽  
...  

The CT manifestation of COVID-19 patients is now well known and essentially reflects pathological changes in the lungs. Actually, there is insufficient knowledge on the long-term outcomes of this new disease, and several chest CTs might be necessary to evaluate the outcomes. The aim of this study is to evaluate the radiation dose for chest CT scans in COVID-19 patients compared to a cohort with pulmonary infectious diseases at the same time of the previous year to value if there is any modification of exposure dose. The analysis of our data shows an increase in the overall mean dose in COVID-19 patients compared with non-COVID-19 patients. In our results, the higher dose increase occurs in the younger age groups (+86% range 21–30 years and +67% range 31–40 years). Our results show that COVID-19 patients are exposed to a significantly higher dose of ionizing radiation than other patients without COVID infectious lung disease, and especially in younger age groups, although some authors have proposed the use of radiotherapy in these patients, which is yet to be validated. Our study has limitations: the use of one CT machine in a single institute and a limited number of patients.


2021 ◽  
Vol 11 (10) ◽  
pp. 4448
Author(s):  
Minoru Osanai ◽  
Hidenori Sato ◽  
Kana Sato ◽  
Kohsei Kudo ◽  
Masahiro Hosoda ◽  
...  

Radiation dose management of medical staff has become increasingly important. Particularly, based on the statement by the International Commission on Radiological Protection (ICRP) in 2011, a new lower equivalent dose limit for the eye lens is being established in each country. Although many reports have discussed the occupational radiation dose in interventional radiology (IR), few studies have examined the dose during computed tomography (CT) examinations. This study investigated the radiation dose exposure to medical staff present in the CT room during irradiation, with particular focus on the exposure to eye lens. The radiation dose exposure to those who assist patients during head, chest and upper abdomen CT examination was measured in a phantom study. The radiation dose exposure with scattered radiation was never negligible (i.e., high); Hp(3) was the highest in head CT examination, at 0.44 mSv per examination. Furthermore, the shielding effect of radiation protection glasses was large, and radiation protection glasses are useful tools for the medical staff who are involved in CT examinations. The justification and optimisation should be carefully considered in assistant actions.


2019 ◽  
Vol 30 (3) ◽  
pp. 1780-1789 ◽  
Author(s):  
David C. Rotzinger ◽  
Vincent Dunet ◽  
Vesna Ilic ◽  
Olivier W. Hugli ◽  
Reto A. Meuli ◽  
...  

Abstract Objectives To determine the prevalence of pulmonary embolism (PE) and alternative diagnoses detected by computed tomography pulmonary angiography (CTPA) in pregnant women; and to assess changes over time regarding radiation dose, technical quality, and examination frequency. Materials and methods This retrospective study included all pregnant women referred for CTPA due to clinically suspected PE over 17 years. Two blinded radiologists reviewed the CTPAs in consensus with regard to PE, alternative diagnoses, and technical quality. We retrieved patient data regarding radiation dose metrics and associated clinical and laboratory parameters. Subgroup comparisons were performed (Wilcoxon and Kruskal-Wallis tests). Results Of the 237 identified patients, 8 (3.3%) were excluded due to inadequate technical CTPA quality, and 229 patients were analyzed (mean age, 31.7 years; mean gestational age, 28 ± 7 weeks). The four different CT systems used over the study period had similar technical quality (p = 0.28). Of 229 patients 16 (7%) patients had PE, 144 (62.9%) had no abnormal findings, and 69 (30.1%) had an alternative diagnosis (consolidation, other pulmonary opacities, pleural effusion, and basal atelectasis). Gestational age, symptoms, and D-dimer levels were not significantly different between patients with or without PE (p > 0.05). Over time, radiation dose exposure decreased by 30% (p < 0.001), while the number of annual examinations increased by > 4-folds. Conclusions In pregnant women, CTPA rarely indicates PE and more often shows alternative diagnoses. Over 17 years, the use of CTPA in pregnancy has notably increased, while the radiation dose exposure has decreased by one third. Key Points • The use of CTPA in pregnancy has steadily risen over the last 17 years • In pregnant women, CTPA rarely reveals PE and more often shows alternative diagnoses • Recent technical improvements have substantially decreased the radiation dose exposure inherent in CTPA without reducing diagnostic image quality


Sign in / Sign up

Export Citation Format

Share Document