Impact of power and contact force on index-guided radiofrequency lesions in an ex vivo porcine heart model

Author(s):  
Cristina Lozano Granero ◽  
Eduardo Franco ◽  
Roberto Matía Francés ◽  
Antonio Hernández-Madrid ◽  
Inmaculada Sánchez-Pérez ◽  
...  
2018 ◽  
Vol 53 (2) ◽  
pp. 141-150 ◽  
Author(s):  
Eduardo Franco ◽  
Daniel Rodríguez Muñoz ◽  
Roberto Matía ◽  
Antonio Hernández-Madrid ◽  
Inmaculada Sánchez Pérez ◽  
...  

2017 ◽  
Vol 11 (2) ◽  
pp. 141-147 ◽  
Author(s):  
Gert Jan Pelgrim ◽  
Taylor M. Duguay ◽  
J. Marco A. Stijnen ◽  
Akos Varga-Szemes ◽  
Sjoerd Van Tuijl ◽  
...  

2012 ◽  
Vol 60 (S 01) ◽  
Author(s):  
JM Abicht ◽  
J Jauch ◽  
S Buchholz ◽  
M Thormann ◽  
B Reichart ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Gert Jan Pelgrim ◽  
Marco Das ◽  
Ulrike Haberland ◽  
Cees Slump ◽  
Astri Handayani ◽  
...  

Objective. To test the feasibility of a CT-compatible,ex vivo, perfused porcine heart model for myocardial perfusion CT imaging.Methods. One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experiment. Stenosis was induced in the circumflex artery, controlled by a fractional flow reserve (FFR) pressure wire. CT-derived myocardial perfusion parameters were analysed at FFR of 1 to 0.10/0.0.Results. CT images did not show major artefacts due to interference of the model setup. The pacemaker-induced heart rhythm was generally stable at 70 beats per minute. During most of the experiment, blood flow was 0.9–1.0 L/min, and arterial pressure varied between 80 and 95 mm/Hg. Blood flow decreased and arterial pressure increased by approximately 10% after inducing a stenosis with FFR ≤ 0.50. Dynamic perfusion scanning was possible across the range of stenosis grades. Perfusion parameters of circumflex-perfused myocardial segments were affected at increasing stenosis grades.Conclusion. An adapted Langendorff porcine heart model is feasible in a CT environment. This model provides control over physiological parameters and may allow in-depth validation of quantitative CT perfusion techniques.


2017 ◽  
Vol 33 (11) ◽  
pp. 1821-1830 ◽  
Author(s):  
Gert Jan Pelgrim ◽  
Marco Das ◽  
Sjoerd van Tuijl ◽  
Marly van Assen ◽  
Frits W. Prinzen ◽  
...  

PLoS ONE ◽  
2018 ◽  
Vol 13 (10) ◽  
pp. e0205850 ◽  
Author(s):  
Jeanette E. Villanueva ◽  
Ling Gao ◽  
Hong C. Chew ◽  
Mark Hicks ◽  
Aoife Doyle ◽  
...  

Heart ◽  
2012 ◽  
Vol 98 (Suppl 1) ◽  
pp. A15-A16 ◽  
Author(s):  
T W Johnson ◽  
S White ◽  
M Gnanadesigan ◽  
H Bourenane ◽  
J W Strange ◽  
...  

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
D Maselli ◽  
R D Johnson ◽  
R Szilveszter Matos ◽  
C Chiappini ◽  
P Camelliti ◽  
...  

Abstract Background The epicardium, the most external layer of the heart, is composed of a layer of epithelial cells and underlying connective tissue. Following myocardial infarction, epicardial cells are activated and provide a source of paracrine factors and progenitor cells. In the border zone of the ischaemic tissue, the activated epicardial cells support cardiac and vascular regeneration by releasing pro-angiogenic and pro-survival factors, and by differentiating towards multiple cell lineages. During this process, activated epicardial cells migrate to the site of injury where they contribute to both post-ischemic remodelling and fibrosis. There is limited knowledge of the cellular and molecular regulation of these processes in large animals and humans, in part due to the lack of robust and representative models. Purpose In this project, we developed an ex vivo 3D organotypic model derived from porcine hearts, amenable to culture, which enables structural, molecular and cellular studies of the epicardium. Methods Thin epicardial/cardiac tissue slices (EpCardio-TS) were obtained by using a vibratome to cut the first layer of tissue from the epicardial side of porcine heart cubes. Slices were cultured for up to 72h in a bioreactor that uses a 3D printed chamber connected to a control system that allows maintenance and adjustment of culture conditions, and ensures continuous media flow. Local intracellular delivery of fluorescent quantum-dots (Qdots) was performed using nanoneedle chips to track epicardial cells, whilst cell fate is visualised in 3D by performing immunofluorescence on decolourised slices. Results Intact EpCardio-TS obtained from porcine heart included a viable epicardium, expressing typical epicardial markers (wt-1, mesothelin, uroplakin), and an electrically active myocardium. Live/dead staining showed epicardial (67.8±16.2%, N=5) and myocardial (40.8±28.6%, N=3) viability, and TUNEL assay confirmed low levels of apoptosis (6.3±5.1% of wt-1+ epicardial cells N=1). Moreover, the presence of proliferating epicardial cells (PCNA+), the increase in wt-1+ cells, and the increase in epicardial gene expression (Tbx18 and TCF21) suggested that cells maintain their progenitor phenotype and undergo activation in culture. Nanoinjection of fluorescent Qdots to EpCardio-TS localized them to the wt-1+ cells on the slice surface, presenting a strategy to mark the epicardial layer. This, combined with the successful decolourisation of the slices, provides an in vitro platform to track the role of epicardial cells in cardiac remodelling and fibrosis. Conclusions EpCardio-TS represents a robust ex vivo model merging the complexity of a 3D organotypic culture with the simplicity of the in vitro culture. EpCardio-TS are amenable to culture and cell tracking, and can therefore find application in toxicology and gene therapy screening for the modulation of epicardial interactions with myocardial and non-myocardial cells of the heart.


Sign in / Sign up

Export Citation Format

Share Document