Selective laser sintering of porous tissue engineering scaffolds from poly(l-lactide)/carbonated hydroxyapatite nanocomposite microspheres

2007 ◽  
Vol 19 (7) ◽  
pp. 2535-2540 ◽  
Author(s):  
Wen You Zhou ◽  
Siu Hang Lee ◽  
Min Wang ◽  
Wai Lam Cheung ◽  
Wing Yuk Ip
Author(s):  
Brock Partee ◽  
Scott J. Hollister ◽  
Suman Das

Tissue engineering combines principles of the life sciences and engineering to replace and repair damaged human tissue. Present practice generally requires the use of porous, bioresorbable scaffolds to serve as temporary 3D templates to guide cell attachment, differentiation, proliferation, and subsequent regenerate tissue formation. Such scaffolds are anticipated to play an important role in allowing physicians to simultaneously reconstruct and regenerate damaged human tissue such as bone, cartilage, ligament and tendon. Recent research strongly suggests the choice of scaffold material and its internal porous architecture significantly influence regenerate tissue structure and function. However, a lack of versatile biomaterials processing and fabrication methods capable of meeting the complex geometric and compositional requirements of tissue engineering scaffolds has slowed progress towards fully testing these promising findings. It is widely accepted that layered manufacturing methods such as selective laser sintering (SLS) have the potential to fulfill these needs. Our research aims to investigate the viability of using SLS to fabricate tissue engineering scaffolds composed of polycaprolactone (PCL), one of the most widely investigated biocompatible, bioresorbable materials for tissue engineering applications. In this work, we report our recent progress on porous scaffold design and fabrication, optimal SLS processing parameter development using systematic factorial design of experiments, and structural characterization via optical microscopy.


2007 ◽  
Vol 334-335 ◽  
pp. 1225-1228 ◽  
Author(s):  
Wen You Zhou ◽  
S.H. Lee ◽  
Min Wang ◽  
W.L. Cheung

This paper reports a study on the modification of a commercial selective laser sintering (SLS) machine for the fabrication of tissue engineering scaffolds from small quantities of poly(L-lactide) (PLLA) microspheres. A miniature build platform was designed, fabricated and installed in the build cylinder of a Sinterstation 2000 system. Porous scaffolds in the form of rectangular prism, 12.7×12.7×25.4 mm3, with interconnected square and round channels were designed using SolidWorks. For initial trials, DuraFormTM polyamide powder was used to build scaffolds with a designed porosity of ~70%. The actual porosity was found to be ~83%, which indicated that the sintered regions were not fully dense. PLLA microspheres in the size range of 5-30 μm were made using an oil-in-water emulsion solvent evaporation procedure and they were suitable for the SLS process. A porous scaffold was sintered from the PLLA microspheres with a laser power of 15W and a part bed temperature of 60oC. SEM examination showed that the PLLA microspheres were partially melted to form the scaffold. This study has demonstrated that it is feasible to build tissue engineering scaffolds from small amounts of biomaterials using a commercial SLS machine with suitable modifications.


2005 ◽  
Vol 128 (2) ◽  
pp. 531-540 ◽  
Author(s):  
Brock Partee ◽  
Scott J. Hollister ◽  
Suman Das

Tissue engineering combines principles of the life sciences and engineering to replace and repair damaged human tissue. Present tissue engineering methods generally require the use of porous, bioresorbable scaffolds to serve as temporary three-dimensional templates to guide cell attachment, differentiation, proliferation, and subsequent regenerate tissue formation. Such scaffolds are anticipated to play an important role in allowing physicians to simultaneously reconstruct and regenerate damaged human tissues such as bone, cartilage, ligament, and tendon. Recent research strongly suggests that the choice of scaffold material and its internal porous architecture significantly influence regenerate tissue structure and function. However, a lack of versatile biomaterials processing and manufacturing methods capable of meeting the complex geometric and compositional requirements of tissue engineering scaffolds has slowed progress towards fully testing these promising findings. It is widely accepted that layered manufacturing methods such as selective laser sintering (SLS) have the potential to address these requirements. We have investigated SLS as a technique to fabricate tissue engineering scaffolds composed of polycaprolactone (PCL), one of the most widely investigated biocompatible, bioresorbable materials for tissue engineering applications. In this article, we report on our development of optimal SLS processing parameters for CAPA® 6501 PCL powder using systematic factorial design of experiments. Using the optimal parameters, we manufactured test scaffolds with designed porous channels and achieved dimensional accuracy to within 3%–8% of design specifications and densities approximately 94% relative to full density. Finally, using the optimal SLS process parameters, we demonstrated the successful fabrication of bone tissue engineering scaffolds based on actual minipig and human condyle scaffold designs.


Author(s):  
Liulan Lin ◽  
Qingxi Hu ◽  
Li Zhao ◽  
Minglun Fang

The growing interest in scaffold-guided tissue engineering (TE) to guide and support cell proliferation in the repair and replacement of bone defects gave rise to the quest for a precise. Rapid prototyping (RP) has been identified as a promising technique capable of building complex objects with pre-designed macro- and microstructures. Calcium phosphate ceramics are biocompatible and may develop interactions with human living bone tissues. They are used clinically on the surface of orthopedic implants to improve primary fixation or in the form of porous blocks. The research focused on the macro and micro-structure of using the selective laser sintering (SLS) technique for creating porous tissue engineering scaffolds. The composite blends obtained by physical blending nano TCP and micro polymer powder binders. The SLS-fabricated test specimens were characterized using XRD and scanning electron microscopy. The total porous volume of the ceramics was over 70% and the pore size from several μm to 600μm. The results obtained ascertained that SLS-fabricated scaffolds have good potential for TE applications.


Sign in / Sign up

Export Citation Format

Share Document