Role of adjuvant therapy with radioactive iodine in patients with elevated serum thyroglobulin after neck reoperation due to recurrent papillary thyroid cancer: a monoinstitutional comparative study

Endocrine ◽  
2019 ◽  
Vol 68 (1) ◽  
pp. 144-150 ◽  
Author(s):  
Pedro Weslley Rosario ◽  
Gabriela Franco Mourão ◽  
Maria Regina Calsolari
2009 ◽  
Vol 34 (1) ◽  
pp. 4-6 ◽  
Author(s):  
Sheng-Fong Kuo ◽  
Tzu-Chieh Chao ◽  
Hung-Yu Chang ◽  
Chuen Hsueh ◽  
Yu-Chen Chang ◽  
...  

2018 ◽  
Vol Volume 11 ◽  
pp. 3551-3560 ◽  
Author(s):  
Jianing Tang ◽  
Deguang Kong ◽  
Qiuxia Cui ◽  
Kun Wang ◽  
Dan Zhang ◽  
...  

2018 ◽  
Vol 90 (1) ◽  
pp. 66-72
Author(s):  
Brittany K. Wise-Oringer ◽  
Marina Goldis ◽  
Molly O. Regelmann ◽  
Michelle Klein ◽  
Josef Machac ◽  
...  

Background: Papillary thyroid cancer (PTC) is an uncommon pediatric disease with an excellent prognosis. In follow-up surveillance, neck ultrasound (US), basal and thyroid-stimulating hormone-stimulated serum thyroglobulin (Tg) levels, and diagnostic whole-body radioactive iodine scans (DxWBS) have been traditionally used in both adults and children for the detection of recurrence or metastases of PTC. Methods: Two pediatric patients with metastatic PTC were followed after standard ablative treatment with routine neck US and serum Tg levels, as well as periodic DxWBS. Results: Neck US identified recurrent and metastatic PTC which DxWBS failed to detect. Conclusion: Neck US was superior to DxWBS in the detection of recurrent PTC in these 2 pediatric patients. These findings are consistent with the 2015 American Thyroid Association (ATA) Guidelines that neck US is an ideal imaging modality in pediatric patients for the surveillance of PTC local recurrence or lymph node metastases.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Fevziye Burcu Sirin ◽  
Hakan Korkmaz

AbstractIn the present study we report a case of thyroglobulin (TGB) measurement interference in a total thyroidectomized and radio-ablated 61-year old woman with papillary thyroid cancer. We investigated possible interference in the measurement of TGB due to discordant TGB in relation to clinical condition during the follow-up period. Serum TGB was measured with the chemiluminescence method using Beckman Coulter Unicel DxI 800 instrument. To investigate possible interference in TGB measurement serial dilutions, polyethylene glycol precipitation (PEG), treatment with heterophile blocking tube (HBT), rheumatoid factor level determination and retesting of TGB with an alternative method were performed. Serial dilutions of the serum sample revealed linearity but a remarkable decrease in TGB in the patient’s serum samples post PEG and post HBT treatments. Also, TGB results under functional sensitivity level obtained with a different method suggested that TGB interference developed due to heterophile antibody presence in the serum sample. The patient had unnecessarily undergone expensive imaging techniques, and invasive procedures such as lymph node fine needle aspiration biopsy, before the analytical interference was suspected by the clinician. This report illustrates the importance of early communication and close collaboration between clinicians and laboratorians in order to avoid unnecessary clinical intervention.


Sign in / Sign up

Export Citation Format

Share Document